Comparing the clinical utility of single-shot echo-planar imaging and readout-segmented echo-planar imaging in diffusion-weighted imaging of the liver at 3 tesla

被引:5
|
作者
Xie, Simin [1 ]
Masokano, Ismail Bilal [1 ]
Liu, Wenguang [1 ]
Long, Xueying [1 ]
Li, Guijin [2 ]
Pei, Yigang [1 ,3 ]
Li, Wenzheng [1 ]
机构
[1] Cent South Univ, Xiangya Hosp, Dept Radiol, Changsha 410008, Hunan, Peoples R China
[2] Siemens Healthcare Ltd, Guangzhou Branch, Guangzhou 510620, Peoples R China
[3] Cent South Univ, Xiangya Hosp, Changsha 410008, Hunan, Peoples R China
基金
中国博士后科学基金;
关键词
Hepatic diffusion-weighted imaging; Single-shot echo-planar imaging (EPI); Readout-segmented EPI; NT-DWI; Clinical utility;
D O I
10.1016/j.ejrad.2020.109472
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the clinical utility of single-shot echo-planar imaging (SS-EPI) using different breathing schemes and readout-segmented EPI (RS-EPI) in the repeatability of apparent diffusion coefficient (ADC) measurements, signal-to-noise ratio (SNR) and image quality. Methods: In this institutional review board-approved prospective study, hepatic DWIs (b = 50, 300, 600 s/mm(2)) were performed in 22 volunteers on 3.0 T MRI using SS-EPI with free-breathing diffusion-weighted imaging (FB-DWI), breath-hold (BH-DWI), respiratory-triggered (RT-DWI) and navigator-triggered (NT-DWI), and readout-segmented EPI (RS-DWI). ADC and surrogate SNR (sSNR) were measured in nine anatomic locations in the right lobe, and image quality was assessed on all FB-DWI, BH-DWI, RT-DWI, NT-DWI, and RS-DWI sequences. The sequence with the optimal clinical utility was decided by systematically comparing the ADC repeatability, sSNR and image quality of the above DWIs. Results: In all the five sequences, NT-DWI had the most reliable intra-observer agreement (intraclass correlation coefficient (ICC): 0.900-0.922; all P > 0.05), and a better interobserver agreement (ICC: 0.853 0.960; all p > 0.05) than RS-DWI (ICC:0.881-0.916; some P < 0.05). NT-DWI had the best ADC repeatability in the nine locations (mean ADC absolute differences: 38.47-56.38 x 10(-6) mm(2)/s, limits of agreement (LOA): 17.33-22.52 x 10(-6) mm(2)/s). Also, NT-DWI had the highest sSNR (Reader 1: 50.58 +/- 20.11 (Superior), 74.06 +/- 28.37 (Central), 80.99 +/- 38.11(Inferior)); Reader 2: 48.07 +/- 23.92 (Superior), 68.23 +/- 32.91 (Central), 76.78 +/- 33.07 (Inferior)) in three representative sections except for RS-DWI. Furthermore, NT-DWI had a better image quality than RS-DWI (P < 0.05) and was superior to FB-DWI and BH-DWI in sharpness of the liver (at b = 300 s/mm(2)) (P < 0.05) Conclusion: RS-DWI has the best SNR. However, NT-DWI can provide sufficient SNR, excellent image quality, and the best ADC repeatability on 3.0 T MRI. It is thus the recommended sequence for the clinical application of hepatic DWI.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Readout-Segmented Echo-Planar Diffusion-Weighted MR Imaging Improves the Differentiation of Breast Cancer Receptor Statuses Compared With Conventional Diffusion-Weighted Imaging
    Zhong, Minghao
    Yang, Zhiqi
    Chen, Xiaofeng
    Huang, Ruibin
    Wang, Mengzhu
    Fan, Weixiong
    Dai, Zhuozhi
    Chen, Xiangguang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (03) : 691 - 699
  • [42] SINGLE-SHOT LOCALIZED ECHO-PLANAR IMAGING (STEAM EPI) AT 4.7 TESLA
    TURNER, R
    VONKIENLIN, M
    MOONEN, CTW
    VANZIJL, PCM
    MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) : 401 - 408
  • [43] Diffusion tensor imaging focusing on lower cervical spinal cord using 2D reduced FOV interleaved multislice single-shot diffusion-weighted echo-planar imaging: comparison with conventional single-shot diffusion-weighted echo-planar imaging
    Park, Eun Hae
    Lee, Young Han
    Jeong, Eun-Kee
    Roh, Yun Ho
    Suh, Jin-Suck
    MAGNETIC RESONANCE IMAGING, 2015, 33 (04) : 401 - 406
  • [44] Single-shot echo-planar imaging with Nyquist ghost compensation: Interleaved dual echo with acceleration (IDEA) echo-planar imaging (EPI)
    Poser, Benedikt A.
    Barth, Markus
    Goa, Pal-Erik
    Deng, Weiran
    Stenger, V. Andrew
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) : 37 - 47
  • [45] Diffusion-weighted MR imaging with single-shot echo-planar imaging in the upper abdomen: preliminary clinical experience in 61 patients
    Ichikawa, T
    Haradome, H
    Hachiya, J
    Nitatori, T
    Araki, T
    ABDOMINAL IMAGING, 1999, 24 (05): : 456 - 461
  • [46] Diffusion-weighted MR imaging with single-shot echo-planar imaging in the upper abdomen: preliminary clinical experience in 61 patients
    T. Ichikawa
    H. Haradome
    J. Hachiya
    T. Nitatori
    T. Araki
    Abdominal Imaging, 1999, 24 : 456 - 461
  • [47] Mediastinal Mass: Assessment with Diffusion-weighted Single Shot Echo-planar MR Imaging
    Razek, Abdel A.
    Elshafeay, M.
    Elhadedy, T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [48] Efficacy of a Nonrigid Image-registration Method in Comparison to Readout-segmented Echo-planar Imaging for Correcting Distortion in Diffusion-weighted Imaging
    Kobata, Takuya
    Yamasaki, Tatsuya
    Katayama, Hiroki
    Ogawa, Kazuo
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2021, 20 (02) : 216 - 221
  • [49] Qualitative and quantitative comparison of image quality between single-shot echo-planar and interleaved multi-shot echo-planar diffusion-weighted imaging in female pelvis
    He An
    Xiaodong Ma
    Ziyi Pan
    Hua Guo
    Elaine Yuen Phin Lee
    European Radiology, 2020, 30 : 1876 - 1884
  • [50] Characterization of focal liver lesions with diffusion-weighted echo-planar imaging
    Laghi, A
    Pavone, P
    Catalano, C
    Panebianco, V
    Fabiano, S
    Baeli, I
    Passariello, R
    HEPATOLOGY, 1999, 30 (04) : 282A - 282A