SINGLE-SHOT LOCALIZED ECHO-PLANAR IMAGING (STEAM EPI) AT 4.7 TESLA

被引:20
|
作者
TURNER, R [1 ]
VONKIENLIN, M [1 ]
MOONEN, CTW [1 ]
VANZIJL, PCM [1 ]
机构
[1] NCI,BETHESDA,MD 20892
关键词
D O I
10.1002/mrm.1910140225
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The resolution and homogeneity limitations of echo‐planar imaging (EPI) are overcome by zoom imaging of an easily shimmed localized volume. Use of the stimulated echo enables single‐shot localization. In vivo 0.5‐mm resolution EPI images of selected regions of a cat brain at 4.7 T are presented. © 1990 Academic Press, Inc. Copyright © 1990 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:401 / 408
页数:8
相关论文
共 50 条
  • [1] SINGLE-SHOT IMAGING INVIVO AT 4.7 TESLA OF LOCALIZED SELECTED VOLUMES BY STEAM-EPI
    VONKIENLIN, M
    TURNER, R
    MOONEN, C
    VANZIJL, P
    BULLETIN OF MAGNETIC RESONANCE, VOL 11, NOS 3/4: PROCEEDINGS OF THE INTERNATIONAL SOCIETY OF MAGNETIC RESONANCE TENTH MEETING, 1989, : 269 - 272
  • [2] Single-shot echo-planar imaging with Nyquist ghost compensation: Interleaved dual echo with acceleration (IDEA) echo-planar imaging (EPI)
    Poser, Benedikt A.
    Barth, Markus
    Goa, Pal-Erik
    Deng, Weiran
    Stenger, V. Andrew
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) : 37 - 47
  • [3] Comparing the clinical utility of single-shot echo-planar imaging and readout-segmented echo-planar imaging in diffusion-weighted imaging of the liver at 3 tesla
    Xie, Simin
    Masokano, Ismail Bilal
    Liu, Wenguang
    Long, Xueying
    Li, Guijin
    Pei, Yigang
    Li, Wenzheng
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 135
  • [4] Quantitative Susceptibility Mapping Using Single-Shot Echo-Planar Imaging
    Sun, Hongfu
    Wilman, Alan H.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (05) : 1932 - 1938
  • [5] Single-shot echo-planar imaging of multiple sclerosis: effects of varying echo time
    Wolansky, LJ
    Chong, S
    Liu, WC
    Kang, E
    Simpson, SW
    Karimi, S
    Akbari, H
    NEURORADIOLOGY, 1999, 41 (03) : 163 - 166
  • [6] Single-shot echo-planar imaging of multiple sclerosis: effects of varying echo time
    L. J. Wolansky
    S. Chong
    W. C. Liu
    E. Kang
    S. W. Simpson
    S. Karimi
    H. Akbari
    Neuroradiology, 1999, 41 : 163 - 166
  • [7] MODIFICATION OF THE CARR-PURCELL SEQUENCE FOR SINGLE-SHOT ECHO-PLANAR IMAGING
    HENNEL, F
    MAGNETIC RESONANCE IN MEDICINE, 1992, 26 (01) : 116 - 121
  • [8] Single-shot velocity mapping by rewinding of velocity encoding with Echo-Planar Imaging
    Serial, Maria R.
    Silletta, Emilia, V
    Perlo, Josefina
    Giovacchini, Juan P.
    Velasco, Manuel, I
    Bluemich, Bernhard
    Danieli, Ernesto D.
    Casanova, Federico
    Acosta, Rodolfo H.
    JOURNAL OF MAGNETIC RESONANCE, 2019, 307
  • [9] Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using Sensitivity Encoding (SENSE)
    Bammer, R
    Keeling, SL
    Augustin, M
    Pruessmann, KP
    Wolf, R
    Stollberger, R
    Hartung, HP
    Fazekas, F
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 548 - 554
  • [10] Comparison of Readout-Segmented Echo-Planar Imaging (EPI) and Single-Shot EPI in Clinical Application of Diffusion-Weighted Imaging of the Pediatric Brain
    Yeom, Kristen W.
    Holdsworth, Samantha J.
    Van, Anh T.
    Iv, Michael
    Skare, Stefan
    Lober, Robert M.
    Bammer, Roland
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (05) : W437 - W443