Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using Sensitivity Encoding (SENSE)

被引:223
|
作者
Bammer, R
Keeling, SL
Augustin, M
Pruessmann, KP
Wolf, R
Stollberger, R
Hartung, HP
Fazekas, F
机构
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[2] Karl Franzens Univ Graz, Magnet Resonance Inst, A-8010 Graz, Austria
[3] Karl Franzens Univ Graz, Dept Neurol, A-8010 Graz, Austria
[4] Karl Franzens Univ Graz, Dept Math, A-8010 Graz, Austria
[5] Karl Franzens Univ Graz, Dept Radiol, A-8010 Graz, Austria
[6] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[7] Swiss Fed Inst Technol, Zurich, Switzerland
关键词
magnetic resonance imaging; diffusion imaging; brain; stroke; parallel imaging;
D O I
10.1002/mrm.1226
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Diffusion-weighted single-shot EPI (sshEPI) is one of the most important tools for the diagnostic assessment of stroke patients, but it suffers from well known artifacts. Therefore, sshEPI was combined with SENSitivity Encoding (SENSE) to further increase EPI's potential for stroke imaging. Eight healthy volunteers and a consecutive series of patients (N = 8) with suspected stroke were examined with diffusion-weighted SENSE-sshEPI using different reduction factors (1.0 less than or equal to R less than or equal to 3.0). Additionally, a high-resolution diffusion-weighted SENSE-sshEPI scan was included. All examinations were diagnostic and of better quality than conventional sshEPI. No ghostings or aliasing artifacts were discernible, and EPI-related image distortions were markedly diminished. Chemical shift artifacts and eddy current-induced image warping were still present, although to a markedly smaller extent. Measured direction-dependent diffusion-coefficients and isotropic diffusion values were comparable to previous findings but showed less fluctuation. We have demonstrated the technical feasibility and clinical applicability of diffusion-weighted SENSE-sshEPI in patients with subacute stroke. Because of the faster k-space traversal, this novel technique is able to reduce typical EPI artifacts and increase spatial resolution while simultaneously remaining insensitive to bulk motion. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:548 / 554
页数:7
相关论文
共 50 条
  • [1] Comparison of multiplexed sensitivity encoding and single-shot echo-planar imaging for diffusion-weighted imaging of the liver
    Kim, Yeun-Yoon
    Kim, Myeong-Jin
    Gho, Sung-Min
    Seo, Nieun
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 132
  • [2] Multiplexed sensitivity-encoding versus single-shot echo-planar imaging: a comparative study for diffusion-weighted imaging of the thyroid lesions
    Xiuyu Wang
    Peng Wang
    Heng Zhang
    Xian Wang
    Jie Shi
    Shudong Hu
    Japanese Journal of Radiology, 2024, 42 : 268 - 275
  • [3] Multiplexed sensitivity-encoding versus single-shot echo-planar imaging: a comparative study for diffusion-weighted imaging of the thyroid lesions
    Wang, Xiuyu
    Wang, Peng
    Zhang, Heng
    Wang, Xian
    Shi, Jie
    Hu, Shudong
    JAPANESE JOURNAL OF RADIOLOGY, 2024, 42 (03) : 268 - 275
  • [4] Differential diagnosis of pancreatic cancer by single-shot echo-planar imaging diffusion-weighted imaging
    Hong, Ben-Zu
    Li, Xin-Feng
    Lin, Jian-Qing
    WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (20) : 6374 - 6380
  • [5] Differential diagnosis of pancreatic cancer by single-shot echo-planar imaging diffusion-weighted imaging
    Ben-Zu Hong
    Xin-Feng Li
    Jian-Qing Lin
    World Journal of Gastroenterology, 2015, (20) : 6374 - 6380
  • [6] Comparison of Readout-Segmented Echo-Planar Imaging (EPI) and Single-Shot EPI in Clinical Application of Diffusion-Weighted Imaging of the Pediatric Brain
    Yeom, Kristen W.
    Holdsworth, Samantha J.
    Van, Anh T.
    Iv, Michael
    Skare, Stefan
    Lober, Robert M.
    Bammer, Roland
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (05) : W437 - W443
  • [7] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Wu, Chen-Jiang
    Wang, Qing
    Zhang, Jing
    Wang, Xiao-Ning
    Liu, Xi-Sheng
    Zhang, Yu-Dong
    Shi, Hai-Bin
    ABDOMINAL RADIOLOGY, 2016, 41 (01) : 100 - 108
  • [8] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Chen-Jiang Wu
    Qing Wang
    Jing Zhang
    Xiao-Ning Wang
    Xi-Sheng Liu
    Yu-Dong Zhang
    Hai-Bin Shi
    Abdominal Radiology, 2016, 41 : 100 - 108
  • [9] Detection of Middle Ear Cholesteatoma by Diffusion-Weighted MR Imaging: Multishot Echo-Planar Imaging Compared with Single-Shot Echo-Planar Imaging
    Yamashita, K.
    Yoshiura, T.
    Hiwatashi, A.
    Kamano, H.
    Dashjamts, T.
    Shibata, S.
    Tamae, A.
    Honda, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (10) : 1915 - 1918
  • [10] Diffusion tensor imaging focusing on lower cervical spinal cord using 2D reduced FOV interleaved multislice single-shot diffusion-weighted echo-planar imaging: comparison with conventional single-shot diffusion-weighted echo-planar imaging
    Park, Eun Hae
    Lee, Young Han
    Jeong, Eun-Kee
    Roh, Yun Ho
    Suh, Jin-Suck
    MAGNETIC RESONANCE IMAGING, 2015, 33 (04) : 401 - 406