Comparing the clinical utility of single-shot echo-planar imaging and readout-segmented echo-planar imaging in diffusion-weighted imaging of the liver at 3 tesla

被引:5
|
作者
Xie, Simin [1 ]
Masokano, Ismail Bilal [1 ]
Liu, Wenguang [1 ]
Long, Xueying [1 ]
Li, Guijin [2 ]
Pei, Yigang [1 ,3 ]
Li, Wenzheng [1 ]
机构
[1] Cent South Univ, Xiangya Hosp, Dept Radiol, Changsha 410008, Hunan, Peoples R China
[2] Siemens Healthcare Ltd, Guangzhou Branch, Guangzhou 510620, Peoples R China
[3] Cent South Univ, Xiangya Hosp, Changsha 410008, Hunan, Peoples R China
基金
中国博士后科学基金;
关键词
Hepatic diffusion-weighted imaging; Single-shot echo-planar imaging (EPI); Readout-segmented EPI; NT-DWI; Clinical utility;
D O I
10.1016/j.ejrad.2020.109472
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the clinical utility of single-shot echo-planar imaging (SS-EPI) using different breathing schemes and readout-segmented EPI (RS-EPI) in the repeatability of apparent diffusion coefficient (ADC) measurements, signal-to-noise ratio (SNR) and image quality. Methods: In this institutional review board-approved prospective study, hepatic DWIs (b = 50, 300, 600 s/mm(2)) were performed in 22 volunteers on 3.0 T MRI using SS-EPI with free-breathing diffusion-weighted imaging (FB-DWI), breath-hold (BH-DWI), respiratory-triggered (RT-DWI) and navigator-triggered (NT-DWI), and readout-segmented EPI (RS-DWI). ADC and surrogate SNR (sSNR) were measured in nine anatomic locations in the right lobe, and image quality was assessed on all FB-DWI, BH-DWI, RT-DWI, NT-DWI, and RS-DWI sequences. The sequence with the optimal clinical utility was decided by systematically comparing the ADC repeatability, sSNR and image quality of the above DWIs. Results: In all the five sequences, NT-DWI had the most reliable intra-observer agreement (intraclass correlation coefficient (ICC): 0.900-0.922; all P > 0.05), and a better interobserver agreement (ICC: 0.853 0.960; all p > 0.05) than RS-DWI (ICC:0.881-0.916; some P < 0.05). NT-DWI had the best ADC repeatability in the nine locations (mean ADC absolute differences: 38.47-56.38 x 10(-6) mm(2)/s, limits of agreement (LOA): 17.33-22.52 x 10(-6) mm(2)/s). Also, NT-DWI had the highest sSNR (Reader 1: 50.58 +/- 20.11 (Superior), 74.06 +/- 28.37 (Central), 80.99 +/- 38.11(Inferior)); Reader 2: 48.07 +/- 23.92 (Superior), 68.23 +/- 32.91 (Central), 76.78 +/- 33.07 (Inferior)) in three representative sections except for RS-DWI. Furthermore, NT-DWI had a better image quality than RS-DWI (P < 0.05) and was superior to FB-DWI and BH-DWI in sharpness of the liver (at b = 300 s/mm(2)) (P < 0.05) Conclusion: RS-DWI has the best SNR. However, NT-DWI can provide sufficient SNR, excellent image quality, and the best ADC repeatability on 3.0 T MRI. It is thus the recommended sequence for the clinical application of hepatic DWI.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Chen-Jiang Wu
    Qing Wang
    Jing Zhang
    Xiao-Ning Wang
    Xi-Sheng Liu
    Yu-Dong Zhang
    Hai-Bin Shi
    Abdominal Radiology, 2016, 41 : 100 - 108
  • [2] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Wu, Chen-Jiang
    Wang, Qing
    Zhang, Jing
    Wang, Xiao-Ning
    Liu, Xi-Sheng
    Zhang, Yu-Dong
    Shi, Hai-Bin
    ABDOMINAL RADIOLOGY, 2016, 41 (01) : 100 - 108
  • [3] Comparing the clinical utility of single-shot, readout-segmented and zoomit echo-planar imaging in diffusion-weighted imaging of the kidney at 3 T
    Liu, Wenguang
    Liu, Hui
    Xie, Simin
    Masokano, Ismail Bilal
    Bai, Yu
    Wang, Xiao
    Zhong, Linhui
    Wu, Yi
    Nie, Jilin
    Zhou, Gaofeng
    Pei, Yigang
    Li, Wenzheng
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [4] Comparing the clinical utility of single-shot, readout-segmented and zoomit echo-planar imaging in diffusion-weighted imaging of the kidney at 3 T
    Wenguang Liu
    Hui Liu
    Simin xie
    Ismail Bilal Masokano
    Yu Bai
    Xiao Wang
    Linhui Zhong
    Yi Wu
    Jilin Nie
    Gaofeng Zhou
    Yigang Pei
    Wenzheng Li
    Scientific Reports, 12
  • [5] Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality
    Kim, Yun Ju
    Kim, Sung Hun
    Kang, Bong Joo
    Park, Chang Suk
    Kim, Hyeon Sook
    Son, Yo Han
    Porter, David Andrew
    Song, Byung Joo
    KOREAN JOURNAL OF RADIOLOGY, 2014, 15 (04) : 403 - 410
  • [6] Readout-segmented echo-planar imaging improves the image quality of diffusion-weighted MR imaging in rectal cancer: Comparison with single-shot echo-planar diffusion-weighted sequences
    Xia, Chun-chao
    Liu, Xi
    Peng, Wan-lin
    Li, Lei
    Zhang, Jin-ge
    Meng, Wen-jian
    Deng, Xiang-bing
    Zuo, Pan-li
    Li, Zhen-lin
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (10) : 1818 - 1823
  • [7] Readout-segmented echo-planar imaging in diffusion-weighted MR imaging of acute infarction of the brainstem and posterior fossa: comparison of single-shot echo-planar diffusion-weighted sequences
    Byeon, Jonghyun
    Kim, Jee Young
    Cho, A-Hyun
    CLINICAL IMAGING, 2015, 39 (05) : 765 - 769
  • [8] Performance of Single-Shot Echo-Planar Imaging in Diffusion Tensor Imaging in Rat Sciatic Nerve Compared With Readout-Segmented Echo-Planar Imaging
    Chen, Yueyao
    Pan, Zhongxian
    Meng, Fanqi
    Li, Zhujing
    Hu, Yuanming
    Yu, Xuewen
    Gao, Jinyun
    Guo, Yihao
    Lyu, Hanqing
    Lin, Xiaofeng
    FRONTIERS IN NEUROSCIENCE, 2022, 16
  • [9] Readout-segmented echo-planar diffusion-weighted imaging in the assessment of orbital tumors: comparison with conventional single-shot echo-planar imaging in image quality and diagnostic performance
    Xu, Xiaoquan
    Wang, Yanjun
    Hu, Hao
    Su, Guoyi
    Liu, Hu
    Shi, Haibin
    Wu, Feiyun
    ACTA RADIOLOGICA, 2017, 58 (12) : 1457 - 1467
  • [10] Readout-segmented diffusion weighted imaging of the testis at 3.0 T: comparison with single-shot echo-planar imaging