Comparing the clinical utility of single-shot echo-planar imaging and readout-segmented echo-planar imaging in diffusion-weighted imaging of the liver at 3 tesla

被引:5
|
作者
Xie, Simin [1 ]
Masokano, Ismail Bilal [1 ]
Liu, Wenguang [1 ]
Long, Xueying [1 ]
Li, Guijin [2 ]
Pei, Yigang [1 ,3 ]
Li, Wenzheng [1 ]
机构
[1] Cent South Univ, Xiangya Hosp, Dept Radiol, Changsha 410008, Hunan, Peoples R China
[2] Siemens Healthcare Ltd, Guangzhou Branch, Guangzhou 510620, Peoples R China
[3] Cent South Univ, Xiangya Hosp, Changsha 410008, Hunan, Peoples R China
基金
中国博士后科学基金;
关键词
Hepatic diffusion-weighted imaging; Single-shot echo-planar imaging (EPI); Readout-segmented EPI; NT-DWI; Clinical utility;
D O I
10.1016/j.ejrad.2020.109472
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the clinical utility of single-shot echo-planar imaging (SS-EPI) using different breathing schemes and readout-segmented EPI (RS-EPI) in the repeatability of apparent diffusion coefficient (ADC) measurements, signal-to-noise ratio (SNR) and image quality. Methods: In this institutional review board-approved prospective study, hepatic DWIs (b = 50, 300, 600 s/mm(2)) were performed in 22 volunteers on 3.0 T MRI using SS-EPI with free-breathing diffusion-weighted imaging (FB-DWI), breath-hold (BH-DWI), respiratory-triggered (RT-DWI) and navigator-triggered (NT-DWI), and readout-segmented EPI (RS-DWI). ADC and surrogate SNR (sSNR) were measured in nine anatomic locations in the right lobe, and image quality was assessed on all FB-DWI, BH-DWI, RT-DWI, NT-DWI, and RS-DWI sequences. The sequence with the optimal clinical utility was decided by systematically comparing the ADC repeatability, sSNR and image quality of the above DWIs. Results: In all the five sequences, NT-DWI had the most reliable intra-observer agreement (intraclass correlation coefficient (ICC): 0.900-0.922; all P > 0.05), and a better interobserver agreement (ICC: 0.853 0.960; all p > 0.05) than RS-DWI (ICC:0.881-0.916; some P < 0.05). NT-DWI had the best ADC repeatability in the nine locations (mean ADC absolute differences: 38.47-56.38 x 10(-6) mm(2)/s, limits of agreement (LOA): 17.33-22.52 x 10(-6) mm(2)/s). Also, NT-DWI had the highest sSNR (Reader 1: 50.58 +/- 20.11 (Superior), 74.06 +/- 28.37 (Central), 80.99 +/- 38.11(Inferior)); Reader 2: 48.07 +/- 23.92 (Superior), 68.23 +/- 32.91 (Central), 76.78 +/- 33.07 (Inferior)) in three representative sections except for RS-DWI. Furthermore, NT-DWI had a better image quality than RS-DWI (P < 0.05) and was superior to FB-DWI and BH-DWI in sharpness of the liver (at b = 300 s/mm(2)) (P < 0.05) Conclusion: RS-DWI has the best SNR. However, NT-DWI can provide sufficient SNR, excellent image quality, and the best ADC repeatability on 3.0 T MRI. It is thus the recommended sequence for the clinical application of hepatic DWI.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Improve the image quality of orbital 3 T diffusion-weighted magnetic resonance imaging with readout-segmented echo-planar imaging
    Xu, Xiao-Quan
    Liu, Jun
    Hu, Hao
    Su, Guo-Yi
    Zhang, Yu-Dong
    Shi, Hai-Bin
    Wu, Fei-Yun
    CLINICAL IMAGING, 2016, 40 (04) : 793 - 796
  • [32] Diffusion-Weighted Imaging-guided MR Spectroscopy in Breast Lesions using Readout-Segmented Echo-Planar Imaging
    Sun, Kun
    Chai, Weimin
    Fu, Caixia
    Zhan, Ying
    Shen, Kunwei
    Luo, Xianfu
    Yan, Fuhua
    EUROPEAN RADIOLOGY, 2016, 26 (06) : 1565 - 1574
  • [33] Diffusion-Weighted Imaging-guided MR Spectroscopy in Breast Lesions using Readout-Segmented Echo-Planar Imaging
    Kun Sun
    Weimin Chai
    Caixia Fu
    Ying Zhan
    Kunwei Shen
    Xianfu Luo
    Fuhua Yan
    European Radiology, 2016, 26 : 1565 - 1574
  • [34] Diffusion tensor imaging analysis of optic radiation using readout-segmented echo-planar imaging
    Yamada, Hirofumi
    Yamamoto, Akira
    Okada, Tomohisa
    Kanagaki, Mitsunori
    Fushimi, Yasutaka
    Mehemed, Taha Mohamed
    Porter, David A.
    Togashi, Kaori
    SURGICAL AND RADIOLOGIC ANATOMY, 2014, 36 (10) : 973 - 980
  • [35] Diffusion tensor imaging analysis of optic radiation using readout-segmented echo-planar imaging
    Hirofumi Yamada
    Akira Yamamoto
    Tomohisa Okada
    Mitsunori Kanagaki
    Yasutaka Fushimi
    Taha Mohamed Mehemed
    David A. Porter
    Kaori Togashi
    Surgical and Radiologic Anatomy, 2014, 36 : 973 - 980
  • [36] Feasibility Study of 3-T DWI of the Prostate: Readout-Segmented Versus Single-Shot Echo-Planar Imaging
    Li, Liang
    Wang, Liang
    Deng, Ming
    Liu, Hui
    Cai, Jie
    Sah, Vivek Kumar
    Liu, Jihong
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (01) : 70 - 76
  • [37] Diffusion-weighted single-shot echo-planar imaging with parallel technique in assessment of endometrial cancer
    Shen, Shu-Huei
    Chiou, Yi-You
    Wang, Jia-Hwia
    Yen, Ming-Shyen
    Lee, Rheun-Chuan
    Lai, Chiung-Ru
    Chang, Cheng-Yen
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (02) : 481 - 488
  • [38] Partial k-space reconstruction in single-shot diffusion-weighted echo-planar imaging
    Storey, Pippa
    Frigo, Fred J.
    Hinks, R. Scott
    Mock, Bryan J.
    Collick, Bruce D.
    Baker, Nicole
    Marmurek, Jonathan
    Graham, Simon J.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (03) : 614 - 619
  • [39] Reproducibility and feasibility of optic nerve diffusion MRI techniques: single-shot echo-planar imaging (EPI), readout-segmented EPI, and reduced field-of-view diffusion-weighted imaging
    Zhou, Fanglu
    Li, Qing
    Zhang, Xiaohui
    Ma, Hongli
    Zhang, Ge
    Du, Silin
    Zhang, Lijun
    Benkert, Thomas
    Zhang, Zhiwei
    BMC MEDICAL IMAGING, 2022, 22 (01)
  • [40] Reproducibility and feasibility of optic nerve diffusion MRI techniques: single-shot echo-planar imaging (EPI), readout-segmented EPI, and reduced field-of-view diffusion-weighted imaging
    Fanglu Zhou
    Qing Li
    Xiaohui Zhang
    Hongli Ma
    Ge Zhang
    Silin Du
    Lijun Zhang
    Thomas Benkert
    Zhiwei Zhang
    BMC Medical Imaging, 22