Performance evaluation of a whole-body prototype PET scanner with four-layer DOI detectors

被引:37
|
作者
Akamatsu, Go [1 ]
Tashima, Hideaki [1 ]
Iwao, Yuma [1 ]
Wakizaka, Hidekatsu [1 ]
Maeda, Takamasa [1 ]
Mohammadi, Akram [1 ]
Takyu, Sodai [1 ]
Nitta, Munetaka [1 ]
Nishikido, Fumihiko [1 ]
Rutherford, Harley [2 ,3 ]
Chacon, Andrew [2 ,3 ]
Safavi-Naeini, Mitra [3 ]
Yoshida, Eiji [1 ]
Yamaya, Taiga [1 ]
机构
[1] Natl Inst Quantum & Radiol Sci & Technol QST, NIRS, Chiba, Japan
[2] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[3] ANSTO, Sydney, NSW, Australia
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2019年 / 64卷 / 09期
关键词
PET; DOI; whole-body; NEMA NU 2; OF-FLIGHT PET/CT; AXIAL-FIELD; RESOLUTION; CRYSTALS; SYSTEM; DESIGN; IMPACT; VIEW; PMT;
D O I
10.1088/1361-6560/ab18b2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Parallax error caused by the detector crystal thickness degrades spatial resolution at the peripheral regions of the field-of-view (FOV) of a scanner. To resolve this issue, depth-of-interaction (DOI) measurement is a promising solution to improve the spatial resolution and its uniformity over the entire FOV. Even though DOI detectors have been used in dedicated systems with a small ring diameter such as for the human brain, breast and small animals, the use of DOI detectors for a large bore whole-body PET system has not been demonstrated yet. We have developed a four-layered DOI detector, and its potential for a brain dedicated system has been proven in our previous development. In the present work, we investigated the use of the four-layer DOI detector for a large bore PET system by developing the world's first whole-body prototype. We evaluated its performance characteristics in accordance with the NEMA NU 2 standard. Furthermore, the impact of incorporating DOI information was evaluated with the NEMA NU 4 image quality phantom. Point source images were reconstructed with a filtered back projection (FBP), and an average spatial resolution of 5.2 +/- 0.7 mm was obtained. For the FBP image, the four-layer DOI information improved the radial spatial resolution by 48% at the 20 cm offset position. The peak noise-equivalent count rate (NECR) was 22.9 kcps at 7.4 kBq ml(-1) and the scatter fraction was 44%. The system sensitivity was 5.9 kcps MBq(-1). For the NEMA NU 2 image quality phantom, the 10 mm sphere was clearly visualized without any artifacts. For the NEMA NU 4 image quality phantom, we measured the phantom at 0, 10 and 20 cm offset positions. As a result, we found the image with four-layer DOI could visualize the 2 mm-diameter hot cylinder although it could not be recognized on the image without DOI. The average improvements in the recovery coefficients for the five hot rods (1-5 mm) were 0.3%, 4.4% and 26.3% at the 0, 10 and 20 cm offset positions, respectively (except for the 1 mm-diameter rod at the 20 cm offset position). Although several practical issues (such as adding end-shields) remain to be addressed before the scanner is ready for clinical use, we showed that the four-layer DOI technology provided higher and more uniform spatial resolution over the FOV and improved contrast for small uptake regions located at the peripheral FOV, which could improve detectability of small and distal lesions such as nodal metastases, especially in obese patients.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Whole-body PET scanner using curve-plate NaI(Ti) detectors.
    Karp, JS
    Muehllehner, G
    Geagan, MJ
    Freifelder, R
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 50P - 50P
  • [32] Impact of event positioning algorithm on performance of a whole-body PET scanner using one-to-one coupled detectors
    Surti, S.
    Karp, J. S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (05):
  • [33] PERFORMANCE-CHARACTERISTICS OF AN 8-RING WHOLE-BODY PET SCANNER
    KOPS, ER
    HERZOG, H
    SCHMID, A
    HOLTE, S
    FEINENDEGEN, LE
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (03) : 437 - 445
  • [34] Performance evaluation of the HAMAMATSU SHR22000 whole-body PET scanner using the IEC standard
    Tian Yi
    Atsushi, Katabe
    Liu Hua-Feng
    Bao Chao
    Takaji, Yamashita
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2006, 30 (11): : 1123 - 1127
  • [35] Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner
    Delso, Gaspar
    Furst, Sebastian
    Jakoby, Bjorn
    Ladebeck, Ralf
    Ganter, Carl
    Nekolla, Stephan G.
    Schwaiger, Markus
    Ziegler, Sibylle, I
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61 : 238S - 245S
  • [36] Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner
    Delso, Gaspar
    Fuerst, Sebastian
    Jakoby, Bjoern
    Ladebeck, Ralf
    Ganter, Carl
    Nekolla, Stephan G.
    Schwaiger, Markus
    Ziegler, Sibylle I.
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (12) : 1914 - 1922
  • [37] Performance evaluation of the whole-body PET scanner ECAT EXACT HR+ following the IEC standard
    Adam, LE
    Zaers, J
    Ostertag, H
    Trojan, H
    Bellemann, ME
    Brix, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 1172 - 1179
  • [38] Four-layer DOI PET detectors using a multi-pixel photon counter array and the light sharing method
    Nishikido, Fumihiko
    Inadama, Naoko
    Yoshida, Eiji
    Murayama, Hideo
    Yamaya, Taiga
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 729 : 755 - 761
  • [39] PRELIMINARY EVALUATION OF EMI WHOLE-BODY SCANNER
    KREEL, L
    JOURNAL BELGE DE RADIOLOGIE, 1976, 59 (03): : 267 - 280
  • [40] PRELIMINARY EVALUATION OF EMI WHOLE-BODY SCANNER
    KREEL, L
    JOURNAL BELGE DE RADIOLOGIE, 1976, 59 (05): : 477 - 477