Wrist blood pressure overestimates blood pressure measured at the upper arm

被引:32
|
作者
Palatini, P [1 ]
Longo, D [1 ]
Toffanin, G [1 ]
Bertolo, O [1 ]
Zaetta, V [1 ]
Pessina, AC [1 ]
机构
[1] Univ Padua, Dept Clin & Expt Med, Padua, Italy
关键词
wrist; forearm; upper arm; blood pressure; measurement; distension;
D O I
10.1097/00126097-200404000-00004
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective Whether blood pressure (BP) measured at the wrist differs from blood pressure measured at the arm is not well known. The aim of this study was to compare the BP readings obtained at the arm with those obtained at the forearm and to assess whether the wrist-arm discrepancies were related to subjects' clinical characteristics. Methods We measured blood pressure at the forearm and at the upper arm in 85 subjects using conventional sphygmomanometry. Wrist-arm blood pressure discrepancies were assessed in relation to gender, age, body mass index, skin-fold thickness, arm size, blood pressure level, and arterial compliance measured with the HDI/Pulsewave CR-2000. Results Blood pressure measured at the wrist consistently overestimated blood pressure taken at the arm with a mean ( +/- SD) discrepancy of 8.2 +/- 9.7/9.2 +/- 6.4 mmHg. The systolic blood pressure differences were greater in men than in women (p=0.006) and, among the men, varied according to arm adiposity (positive association, p=0.01). In men, diastolic blood pressure differences correlated with diastolic blood pressure level (negative association, p=0.01). Among the women, only age (p=0.04) was a significant Positive independent predictor of the wrist-arm diastolic BP differences. Conclusions These results indicate that forearm blood pressure measurement markedly overestimates upper arm blood pressure and that the between-site difference may vary from subject to subject. Wrist blood pressure measurement is not a valid alternative to traditional measurement at the arm and its use should be discouraged. (C) 2004 Lippincott Williams Wilkins.
引用
收藏
页码:77 / 81
页数:5
相关论文
共 50 条
  • [31] Blood pressure control with monitoring ambulatory blood pressure (AMBP), self-measured blood pressure at home (SMBP) and office blood pressure
    Gomez-Marcos, M. A.
    Garcia-Ortiz, L.
    Gonzalez Elena, L. J.
    Castano-Sanchez, Y.
    Rodriguez, J. I. Recio
    Parra-Sanchez, J.
    Garcia-Garcia, A.
    Cascon-Perez-Teijon, S.
    Gonzalez-Garcia, A.
    Herrero-Rodriguez, C.
    Sanchez-Salgado, B.
    Rodriguez Martin, C.
    Sanchez, C. Castano
    Jimenez, D. Munoz
    De Cabo-Laso, A.
    JOURNAL OF HYPERTENSION, 2008, 26 : S292 - S292
  • [32] Patient Preferences And Experiences With Cuffless Wrist Versus Upper Arm Cuff Blood Pressure Measurements In The COntinual Vs. OccasionaL Blood Pressure Monitoring (COOL-BP) Study
    Unlu, Ozan
    Lee, Simin
    Gabovitch, Daniel
    Perruchoud, David
    Almeida, Tiago
    Collins, Emma
    Figueroa, Christian
    Ruggiero, Ryan
    Chin, Nicholas
    Cannon, Christopher P.
    Scirica, Benjamin
    Fisher, Naomi D.
    HYPERTENSION, 2023, 80
  • [33] A comparison of oscillometric blood pressure measurement from the upper arm and hand
    Hynson, JM
    Boulay, J
    Fung, N
    Wu, K
    Katz, JA
    ANESTHESIOLOGY, 1999, 91 (3A) : U271 - U271
  • [34] Home blood pressure measurement with oscillometric upper-arm devices
    Braam, RL
    Thien, T
    NETHERLANDS JOURNAL OF MEDICINE, 2003, 61 (10): : 307 - 312
  • [35] Accuracy of the new wrist blood pressure monitor (Omron 637 IT) for blood pressure measurement
    Altunkan, S
    Iliman, N
    Altunkan, E
    JOURNAL OF HYPERTENSION, 2003, 21 : S22 - S22
  • [36] EFFECT OF AN UPPER-ARM CONSTRICTING DEVICE ON ARM BLOOD-PRESSURE MEASUREMENTS
    WOOD, DR
    SIMMONS, JO
    JOURNAL OF THE AMERICAN OSTEOPATHIC ASSOCIATION, 1990, 90 (12): : 1081 - 1084
  • [37] The accuracy of wrist blood pressure oscillometers depends on pulse pressure
    Westhoff, T.
    JOURNAL OF HYPERTENSION, 2007, 25 : S161 - S161
  • [38] The impact of pulse pressure on the accuracy of wrist blood pressure measurement
    Westhoff, T. H.
    Schmidt, S.
    Meissner, R.
    Zidek, W.
    van der Giet, M.
    JOURNAL OF HUMAN HYPERTENSION, 2009, 23 (06) : 391 - 395
  • [39] The impact of pulse pressure on the accuracy of wrist blood pressure measurement
    T H Westhoff
    S Schmidt
    R Meissner
    W Zidek
    M van der Giet
    Journal of Human Hypertension, 2009, 23 : 391 - 395
  • [40] Response to prognostic significance of between-arm blood pressure differences: Between-arm blood pressure difference and mortality and the interarm blood pressure difference: Between-arm blood pressure differences are important