The impact of pulse pressure on the accuracy of wrist blood pressure measurement

被引:0
|
作者
T H Westhoff
S Schmidt
R Meissner
W Zidek
M van der Giet
机构
[1] Charité—Campus Benjamin Franklin,Department of Nephrology
来源
关键词
wrist; blood pressure measurement; pulse pressure; arterial stiffness;
D O I
暂无
中图分类号
学科分类号
摘要
There is an increasing number of wrist blood pressure measurement devices that successfully passed the validation procedures of the British Hypertension Society (BHS) and the European Society of Hypertension (ESH). It remains unknown, however, whether pulse pressure as a marker of arterial stiffness and vascular ageing affects the accuracy of these devices. An ESH protocol validated wrist device was compared with the upper arm mercury sphygmomanometry in a study population (33 patients, 99 measurements) including a relevant number of subjects with pulse pressure >50 mm Hg (84.8%) and isolated systolic hypertension (27.3%). Mean systolic bias was 10.2 mm Hg with 95% limits of agreement of −13.1 and 33.6 mm Hg, mean diastolic bias was 4.8 mm Hg with limits of agreement of −11.0 and 20.7 mm Hg. The impact of body mass index, age, systolic blood pressure and pulse pressure on the absolute value of blood pressure bias was tested by stepwise multiple regression analysis. The systolic bias significantly depended on pulse pressure, whereas there was no significant effect of the independent variables on the diastolic bias. Separate correlation analysis showed a significant correlation between pulse pressure and both absolute systolic bias (Pearson r=0.48, P<0.001) and relative systolic bias (systolic bias divided by systolic blood pressure, Pearson r=0.29, P=0.003). Even well-validated wrist blood pressure devices can show a clinically relevant bias in patients with elevated pulse pressure. Increased arterial stiffness may impair the accuracy of oscillometric blood pressure measurement at the wrist.
引用
收藏
页码:391 / 395
页数:4
相关论文
共 50 条
  • [1] The impact of pulse pressure on the accuracy of wrist blood pressure measurement
    Westhoff, T. H.
    Schmidt, S.
    Meissner, R.
    Zidek, W.
    van der Giet, M.
    [J]. JOURNAL OF HUMAN HYPERTENSION, 2009, 23 (06) : 391 - 395
  • [2] The accuracy of wrist blood pressure oscillometers depends on pulse pressure
    Westhoff, T.
    [J]. JOURNAL OF HYPERTENSION, 2007, 25 : S161 - S161
  • [3] Accuracy of the new wrist blood pressure monitor (Omron 637 IT) for blood pressure measurement
    Altunkan, S
    Iliman, N
    Altunkan, E
    [J]. JOURNAL OF HYPERTENSION, 2003, 21 : S22 - S22
  • [4] Effect of Pressurization Methods on the Accuracy of Wrist Blood Pressure Measurement
    Kim, Jong Pal
    Bae, Sangkon
    Kim, Youn Ho
    Kang, KyoungHo
    Ko, Byung-Hoon
    Kim, Seok Chan
    Shin, Kunsoo
    [J]. 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 5744 - 5747
  • [5] Accuracy of wrist cuff oscillometric blood pressure measurement in obese patients
    Wertli, M.
    Ruckstuhl, N.
    Vetter, W.
    Suter, P. M.
    [J]. JOURNAL OF HYPERTENSION, 2007, 25 : S25 - S25
  • [6] The impact of arm position and pulse pressure on the validation of a wrist-cuff blood pressure measurement device in a high risk population
    Khoshdel, Ali Reza
    Carney, Shane
    Gillies, Alastair
    [J]. INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2010, 3 : 119 - 125
  • [7] Accuracy of pulse interval timing in ambulatory blood pressure measurement
    Kane, Sarah A.
    Blake, James R.
    McArdle, Frank J.
    Langley, Philip
    Sims, Andrew J.
    [J]. SCIENTIFIC REPORTS, 2016, 6
  • [8] Accuracy of pulse interval timing in ambulatory blood pressure measurement
    Sarah A. Kane
    James R. Blake
    Frank J. McArdle
    Philip Langley
    Andrew J. Sims
    [J]. Scientific Reports, 6
  • [9] The Wavelet Transform of Pulse Wave and Electrocardiogram Improves Accuracy of Blood Pressure Estimation in Cuffless Blood Pressure Measurement
    Yamanaka, Syunsuke
    Morikawa, Koji
    Yamamura, Osamu
    Morita, Hiroshi
    Huh, Ji Young
    [J]. CIRCULATION, 2016, 134
  • [10] The Wavelet Transform of Pulse Wave and Electrocardiogram Improves Accuracy of Blood Pressure Estimation in Cuffless Blood Pressure Measurement
    Yamanaka, Syunsuke
    Morikawa, Koji
    Yamamura, Osamu
    Morita, Hiroshi
    Huh, Ji Young
    [J]. CIRCULATION, 2016, 134