Wrist blood pressure overestimates blood pressure measured at the upper arm

被引:32
|
作者
Palatini, P [1 ]
Longo, D [1 ]
Toffanin, G [1 ]
Bertolo, O [1 ]
Zaetta, V [1 ]
Pessina, AC [1 ]
机构
[1] Univ Padua, Dept Clin & Expt Med, Padua, Italy
关键词
wrist; forearm; upper arm; blood pressure; measurement; distension;
D O I
10.1097/00126097-200404000-00004
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective Whether blood pressure (BP) measured at the wrist differs from blood pressure measured at the arm is not well known. The aim of this study was to compare the BP readings obtained at the arm with those obtained at the forearm and to assess whether the wrist-arm discrepancies were related to subjects' clinical characteristics. Methods We measured blood pressure at the forearm and at the upper arm in 85 subjects using conventional sphygmomanometry. Wrist-arm blood pressure discrepancies were assessed in relation to gender, age, body mass index, skin-fold thickness, arm size, blood pressure level, and arterial compliance measured with the HDI/Pulsewave CR-2000. Results Blood pressure measured at the wrist consistently overestimated blood pressure taken at the arm with a mean ( +/- SD) discrepancy of 8.2 +/- 9.7/9.2 +/- 6.4 mmHg. The systolic blood pressure differences were greater in men than in women (p=0.006) and, among the men, varied according to arm adiposity (positive association, p=0.01). In men, diastolic blood pressure differences correlated with diastolic blood pressure level (negative association, p=0.01). Among the women, only age (p=0.04) was a significant Positive independent predictor of the wrist-arm diastolic BP differences. Conclusions These results indicate that forearm blood pressure measurement markedly overestimates upper arm blood pressure and that the between-site difference may vary from subject to subject. Wrist blood pressure measurement is not a valid alternative to traditional measurement at the arm and its use should be discouraged. (C) 2004 Lippincott Williams Wilkins.
引用
收藏
页码:77 / 81
页数:5
相关论文
共 50 条
  • [41] Inaccuracy of wrist-cuff oscillometric blood pressure devices: an arm position artefact?
    Mourad, A
    Gillies, A
    Carney, S
    BLOOD PRESSURE MONITORING, 2005, 10 (02) : 67 - 71
  • [42] How should blood pressure be measured? Con: the peripheral blood pressure is sufficient
    van der Giet, Markus
    KIDNEY INTERNATIONAL, 2023, 103 (01) : 38 - 40
  • [43] Could the arm blood pressure measured with simultaneous bilateral arm method be used for hypertension diagnosis?
    Wan, Taixuan
    Wu, Yuanhao
    He, Ziqiang
    Su, Hai
    BMJ OPEN, 2020, 10 (09): : e037838
  • [44] Measured Blood Pressure, Genetically Predicted Blood Pressure, And Cardiovascular Disease Risk
    Cho, So Mi J.
    Koyama, Satoshi
    Ruan, Yunfeng
    Lannery, Kim
    Wong, Megan
    Ajufo, Ezimamaka
    Lee, Hokyou
    Khera, Amit V.
    Honigberg, Michael
    Natarajan, Pradeep
    HYPERTENSION, 2022, 79
  • [45] Wrist blood pressure versus clinic, self-measured home and ambulatory blood pressure. Relationships with left ventricular mass.
    Jula, A
    Karanko, H
    AMERICAN JOURNAL OF HYPERTENSION, 1999, 12 (04) : 165A - 165A
  • [46] Blood pressure monitor with a position sensor for wrist placement to eliminate hydrostatic pressure effect on blood pressure measurement
    Sato, Hironori
    Koshimizu, Hiroshi
    Yamashita, Shingo
    Ogura, Toshihiko
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 1835 - 1838
  • [47] INTER-ARM DIFFERENCES IN MEASURED BRACHIAL SYSTOLIC BLOOD PRESSURE TRANSLATE TO FALSE DIFFERENCES IN CALCULATED CENTRAL AORTIC BLOOD PRESSURE
    Butlin, M.
    Cook, M. T. D.
    Theobald, D. A.
    Avolio, A. P.
    Peebles, K.
    HYPERTENSION, 2017, 69 (06) : E30 - E30
  • [48] Comparison of a wrist cuff oscillometric blood pressure measurement device with an upper arm-cuff oscillometric device in obese subjects
    de Senarclens, Olivier
    Feihl, Francois
    Giusti, Vittorio
    Engelberger, Rolf P.
    Rodieux, Frederique
    Gomez, Patrick
    Liaudet, Lucas
    Waeber, Bernard
    JOURNAL OF HYPERTENSION, 2006, 24 : 173 - 173
  • [49] Comparison Of Automated Office Blood Pressure And Self-Measured Blood Pressure: Results From An Ongoing Self-Measured Blood Pressure Program
    Farahmand, Rosemary
    Cluett, Jennifer L.
    Barkowski, Laken
    Cohen, Marc L.
    Li, Jonathan X.
    Olowoyeye, Ruth
    Padwal, Raj
    Rakotz, Michael K.
    Russo, Elisabeth
    Sachdev, Neha
    Tighe, Katherine M.
    Tsipas, Stavros
    Walley, Hannah
    Wood, Peter S.
    Wozniak, Gregory
    Juraschek, Stephen P.
    HYPERTENSION, 2023, 80
  • [50] Blood pressure estimation and its recalibration assessment using wrist cuff blood pressure monitor
    Seo, Youjung
    Kwon, Saehim
    Sunarya, Unang
    Park, Sungmin
    Park, Kwangsuk
    Jung, Dawoon
    Cho, Youngho
    Park, Cheolsoo
    BIOMEDICAL ENGINEERING LETTERS, 2023, 13 (02) : 221 - 233