Photoplethysmography for an independent measure of pulsatile pressure under controlled flow conditions

被引:7
|
作者
Njoum, Haneen [1 ]
Kyriacou, Panayiotis A. [1 ]
机构
[1] City Univ London, Biomed Engn Res Ctr, London EC1V 0HB, England
关键词
photoplethysmography; non-invasive pressure; hemodynamics; diagnostics; optical sensors; ACCURACY; DEVICE; AGREEMENT;
D O I
10.1088/1361-6579/38/2/87
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Noninvasive continuous blood pressure measurements are desirable for patients and clinicians. This work proposes and validates a method for transmural pressure measurement using photoplethysmography (PPG) in an in vitro setup that allows control of pressure and flow conditions. The optimum pulsatile volume measure is obtained by comparing parameters extracted from the photoplethysmographic signal (AC amplitude, normalized pulse volume (NPV) and adjusted pulse volume (APV)). Pulsatile volume can then provide pressure measurements using the exponential pressure-volume (P-V) relationship and validated using the gold standard catheter pressure measurement. Pressure, red (R) and infrared (IR) PPG signals were recorded continuously in two arterial models with different cross-sectional areas (Model 1 and Model 2) utilising a pulsatile pump. Flow rates were controlled by varying pumping frequencies at low and high stroke volumes. The optimum method for estimation of the pulsatile volume is through APV, which had a highly significant correlation (r(2) = 0.99, p < 0.001) for Model 1 and (r(2) = 0.98, p < 0.001) for Model 2. APV obtained a significantly better fit when compared to NPVIR (r(2) = 0.73, z = 25.85, p < 0.001), NPVR (r(2) = 0.95, z = 12.26, p < 0.001), IRAC (r(2) = 0.52, z = 28.29, p < 0.0001) and RAC (r(2) = 0.92, z = 15.27, p < 0.0001) in Model 1, and when compared to NPVIR (r(2) = 0.92, z = 10.23, p < 0.0001), NPVR (r(2) = 0.96, z = 5.08, p < 0.001) IRAC (r(2) = 0.63, z = 22.47, p < 0.0001) and R-AC (r(2) = 0.92, z = 17.70, p < 0.0001) in Model 2. These preliminary findings suggest that APV could be used as a potential non-invasive continuous method of blood pressure measurement at different flow conditions.
引用
收藏
页码:87 / 100
页数:14
相关论文
共 50 条
  • [1] A SERVO-CONTROLLED ROLLER-PUMP FOR CONSTANT FLOW OR CONSTANT PRESSURE BLOOD PERFUSION UNDER NORMAL PULSATILE OR NON-PULSATILE CONDITIONS
    BORGSTROM, P
    CLEMENTZ, LA
    GRANDE, PO
    ACTA PHYSIOLOGICA SCANDINAVICA, 1981, 112 (04): : 437 - 442
  • [2] Platelet Adhesion to Polyurethane Urea Under Pulsatile Flow Conditions
    Navitsky, Michael A.
    Taylor, Joshua O.
    Smith, Alexander B.
    Slattery, Margaret J.
    Deutsch, Steven
    Siedlecki, Christopher A.
    Manning, Keefe B.
    ARTIFICIAL ORGANS, 2014, 38 (12) : 1046 - 1053
  • [3] Utilization of Retinal Vein Photoplethysmography to Measure Intracranial Pressure
    Morgan, Bill
    Khoo, Ying Jo
    Kermode, Alan
    Lind, Chris
    Hazelton, Martin
    Rahman, Anmar
    Yu, Dao-Yi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [4] Utilisation of retinal vein photoplethysmography to measure intracranial pressure
    Morgan, William H.
    Khoo, Ying Jo
    Kermode, Allan G.
    Lind, Christopher R.
    Hazelton, Martin L.
    Parsons, Kirsty E.
    Yu, Dao Yi
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2021, 92 (01): : 104 - 106
  • [5] The Characteristics of Turbulence in Curved Pipes under Highly Pulsatile Flow Conditions
    Kalpakli, A.
    Orlu, R.
    Tillmark, N.
    Alfredsson, P. Henrik
    PROGRESS IN TURBULENCE V, 2014, 149 : 183 - 187
  • [6] LEAKAGE RATES FROM A PUNCTURED VESSEL UNDER PULSATILE FLOW CONDITIONS
    McGarry, M.
    Hitt, D. L.
    Harris, T. R.
    ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2008, 2 (03) : 275 - 283
  • [7] A novel photoplethysmography technique to derive normalized arterial stiffness as a blood pressure independent measure in the finger vascular bed
    Tanaka, Gohichi
    Yamakoshi, Ken-ichi
    Sawada, Yukihiro
    Matsumura, Kenta
    Maeda, Kimihito
    Kato, Yuichi
    Horiguchi, Masami
    Ohguro, Hiroshi
    PHYSIOLOGICAL MEASUREMENT, 2011, 32 (11) : 1869 - 1883
  • [8] Evaluation of aging of chemical additives under controlled conditions of pressure, flow rate and temperature
    da Silva, Carla Michele Frota
    da Silva, Edilson Domingos
    Celestino, Gustavo de Gusmao
    Castro, Bruno Barbosa
    Lucas, Elizabete Fernandes
    PETROLEUM SCIENCE AND TECHNOLOGY, 2025, 43 (09) : 930 - 948
  • [9] Computing pulsatile blood flow of coronary artery under incomplete boundary conditions
    Pu, WenJun
    Chen, Yan
    Zhao, Shuai
    Yu, Tiantong
    Lin, Heqiang
    Gao, Haokao
    Xie, Songyun
    Zhang, Xi
    Zhang, Bohui
    Li, Chengxiang
    Lian, Kun
    Xie, Xinzhou
    MEDICAL ENGINEERING & PHYSICS, 2024, 130
  • [10] Modeling of cross-flow osmotic pressure controlled membrane separation processes under turbulent flow conditions
    Sreenivas, K
    Ragesh, P
    DasGupta, S
    De, S
    JOURNAL OF MEMBRANE SCIENCE, 2002, 201 (1-2) : 203 - 212