Photoplethysmography for an independent measure of pulsatile pressure under controlled flow conditions

被引:7
|
作者
Njoum, Haneen [1 ]
Kyriacou, Panayiotis A. [1 ]
机构
[1] City Univ London, Biomed Engn Res Ctr, London EC1V 0HB, England
关键词
photoplethysmography; non-invasive pressure; hemodynamics; diagnostics; optical sensors; ACCURACY; DEVICE; AGREEMENT;
D O I
10.1088/1361-6579/38/2/87
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Noninvasive continuous blood pressure measurements are desirable for patients and clinicians. This work proposes and validates a method for transmural pressure measurement using photoplethysmography (PPG) in an in vitro setup that allows control of pressure and flow conditions. The optimum pulsatile volume measure is obtained by comparing parameters extracted from the photoplethysmographic signal (AC amplitude, normalized pulse volume (NPV) and adjusted pulse volume (APV)). Pulsatile volume can then provide pressure measurements using the exponential pressure-volume (P-V) relationship and validated using the gold standard catheter pressure measurement. Pressure, red (R) and infrared (IR) PPG signals were recorded continuously in two arterial models with different cross-sectional areas (Model 1 and Model 2) utilising a pulsatile pump. Flow rates were controlled by varying pumping frequencies at low and high stroke volumes. The optimum method for estimation of the pulsatile volume is through APV, which had a highly significant correlation (r(2) = 0.99, p < 0.001) for Model 1 and (r(2) = 0.98, p < 0.001) for Model 2. APV obtained a significantly better fit when compared to NPVIR (r(2) = 0.73, z = 25.85, p < 0.001), NPVR (r(2) = 0.95, z = 12.26, p < 0.001), IRAC (r(2) = 0.52, z = 28.29, p < 0.0001) and RAC (r(2) = 0.92, z = 15.27, p < 0.0001) in Model 1, and when compared to NPVIR (r(2) = 0.92, z = 10.23, p < 0.0001), NPVR (r(2) = 0.96, z = 5.08, p < 0.001) IRAC (r(2) = 0.63, z = 22.47, p < 0.0001) and R-AC (r(2) = 0.92, z = 17.70, p < 0.0001) in Model 2. These preliminary findings suggest that APV could be used as a potential non-invasive continuous method of blood pressure measurement at different flow conditions.
引用
收藏
页码:87 / 100
页数:14
相关论文
共 50 条
  • [21] Comparative analysis of pulsatile nanofluid flow under slip conditions through stenosed arteries
    Dawood, A. S.
    Kroush, Faisal A.
    Abumandour, Ramzy M.
    Eldesoky, Islam M.
    BOUNDARY VALUE PROBLEMS, 2025, 2025 (01):
  • [22] Measurement and modeling of preferential flow under controlled conditions
    Mohanty, BP
    Castiglione, P
    Shouse, PJ
    van Genuchten, MT
    PREFERENTIAL FLOW: WATER MOVEMENT AND CHEMICAL TRANSPORT IN THE ENVIRONMENT, 2000, : 77 - 80
  • [23] The effect of asymmetry in abdominal aortic aneurysms under physiologically realistic pulsatile flow conditions
    Finol, EA
    Keyhani, K
    Amon, CH
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (02): : 207 - 217
  • [24] Formation of surface nanodroplets under controlled flow conditions
    Zhang, Xuehua
    Lu, Ziyang
    Tan, Huanshu
    Bao, Lei
    He, Yinghe
    Sun, Chao
    Lohse, Detlef
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2015, 112 (30) : 9253 - 9257
  • [25] Characteristics of a newly designed aortofemoral prosthetic Y graft under pulsatile flow conditions
    Fujimoto, T
    Nakano, S
    Iwamura, H
    Shiraishi, Y
    Yambe, T
    Umezu, M
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2006, 29 (05): : 548 - 548
  • [26] How to measure the decoherence of a micromaser field under well controlled conditions
    Rinner, S
    Walther, H
    Werner, E
    PHYSICAL REVIEW LETTERS, 2004, 93 (16) : 160407 - 1
  • [27] Bridge pier scour under pressure flow conditions
    Carnacina, Iacopo
    Pagliara, Stefano
    Leonardi, Nicoletta
    RIVER RESEARCH AND APPLICATIONS, 2019, 35 (07) : 844 - 854
  • [28] A NEW METHOD TO MEASURE THE CONDENSATION PRESSURE OF AMALGAM UNDER INVIVO CONDITIONS
    LUSSI, AS
    BUERGIN, WB
    JOURNAL OF DENTAL RESEARCH, 1987, 66 (03) : 737 - 739
  • [29] The Effect of Blood Rheology and Inlet Boundary Conditions on Realistic Abdominal Aortic Aneurysms under Pulsatile Flow Conditions
    Tzirakis, Konstantinos
    Kamarianakis, Yiannis
    Kontopodis, Nikolaos
    Ioannou, Christos V. V.
    BIOENGINEERING-BASEL, 2023, 10 (02):
  • [30] DEVELOPMENT OF A PULSATILE SIMULATOR FOR IN-VITRO ANALYSIS OF THE MITRAL VALVE UNDER CONTROLLED MORPHOMETRIC CONDITIONS
    Pavesi, Andrea
    Vismara, Riccardo
    Votta, Emiliano
    Fiore, Gianfranco B.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 535 - 536