Photoplethysmography for an independent measure of pulsatile pressure under controlled flow conditions

被引:7
|
作者
Njoum, Haneen [1 ]
Kyriacou, Panayiotis A. [1 ]
机构
[1] City Univ London, Biomed Engn Res Ctr, London EC1V 0HB, England
关键词
photoplethysmography; non-invasive pressure; hemodynamics; diagnostics; optical sensors; ACCURACY; DEVICE; AGREEMENT;
D O I
10.1088/1361-6579/38/2/87
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Noninvasive continuous blood pressure measurements are desirable for patients and clinicians. This work proposes and validates a method for transmural pressure measurement using photoplethysmography (PPG) in an in vitro setup that allows control of pressure and flow conditions. The optimum pulsatile volume measure is obtained by comparing parameters extracted from the photoplethysmographic signal (AC amplitude, normalized pulse volume (NPV) and adjusted pulse volume (APV)). Pulsatile volume can then provide pressure measurements using the exponential pressure-volume (P-V) relationship and validated using the gold standard catheter pressure measurement. Pressure, red (R) and infrared (IR) PPG signals were recorded continuously in two arterial models with different cross-sectional areas (Model 1 and Model 2) utilising a pulsatile pump. Flow rates were controlled by varying pumping frequencies at low and high stroke volumes. The optimum method for estimation of the pulsatile volume is through APV, which had a highly significant correlation (r(2) = 0.99, p < 0.001) for Model 1 and (r(2) = 0.98, p < 0.001) for Model 2. APV obtained a significantly better fit when compared to NPVIR (r(2) = 0.73, z = 25.85, p < 0.001), NPVR (r(2) = 0.95, z = 12.26, p < 0.001), IRAC (r(2) = 0.52, z = 28.29, p < 0.0001) and RAC (r(2) = 0.92, z = 15.27, p < 0.0001) in Model 1, and when compared to NPVIR (r(2) = 0.92, z = 10.23, p < 0.0001), NPVR (r(2) = 0.96, z = 5.08, p < 0.001) IRAC (r(2) = 0.63, z = 22.47, p < 0.0001) and R-AC (r(2) = 0.92, z = 17.70, p < 0.0001) in Model 2. These preliminary findings suggest that APV could be used as a potential non-invasive continuous method of blood pressure measurement at different flow conditions.
引用
收藏
页码:87 / 100
页数:14
相关论文
共 50 条
  • [31] FLUIDICALLY OPERATED PULSATILE PRESSURE AND FLOW GENERATOR
    JORGENSEN, J
    COUTURE, RK
    ISA TRANSACTIONS, 1971, 10 (03) : 314 - +
  • [32] PULSATILE PRESSURE AND FLOW THROUGH DISTENSIBLE VESSELS
    STREETER, VL
    BOHR, DF
    KEITZER, WF
    CIRCULATION RESEARCH, 1963, 13 (01) : 3 - &
  • [33] A FLUIDICALLY OPERATED PULSATILE PRESSURE AND FLOW GENERATOR
    JORGENSE.J
    INSTRUMENTATION TECHNOLOGY, 1970, 17 (09): : 60 - &
  • [34] PULSATILE PRESSURE AND FLOW IN THE RABBIT MESENTERIC CIRCULATION
    NAMMALWAR, P
    HATTER, JE
    PERLL, PD
    GROSS, DR
    FASEB JOURNAL, 1995, 9 (04): : A907 - A907
  • [35] Transitional flow field characterization inside an arteriovenous graft-to-vein anastomosis under pulsatile flow conditions
    Arslan, N
    Loth, F
    Bertram, CD
    Bassiouny, HS
    EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2005, 24 (03) : 353 - 365
  • [36] DIFFUSION OF PHOSPHORUS INTO SILICON UNDER CONDITIONS OF CONTROLLED VAPOUR PRESSURE
    COUPLAND, MJ
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON, 1959, 73 (472): : 577 - 584
  • [37] Mechanical buckling of artery under pulsatile pressure
    Liu, Qin
    Han, Hai-Chao
    JOURNAL OF BIOMECHANICS, 2012, 45 (07) : 1192 - 1198
  • [38] Modified Beer-Lambert algorithm to measure pulsatile blood flow, critical closing pressure, and intracranial hypertension
    Baker, Wesley B.
    Forti, Rodrigo M.
    Heye, Pascal
    Heye, Kristina
    Lynch, Jennifer M.
    Yodh, Arjun G.
    Licht, Daniel J.
    White, Brian R.
    Hwang, Misun
    Ko, Tiffany S.
    Kilbaugh, Todd J.
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (09): : 5511 - 5532
  • [39] Scaling laws for wall shear stress through stenoses under steady and pulsatile flow conditions
    Chua, LP
    Yu, SCM
    Xue, Q
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H5) : 503 - 514
  • [40] Investigation of the Characteristics of HeartWare HVAD and Thoratec HeartMate II Under Steady and Pulsatile Flow Conditions
    Noor, Mumin R.
    Ho, Chong H.
    Parker, Kim H.
    Simon, Andre R.
    Banner, Nicholas R.
    Bowles, Christopher T.
    ARTIFICIAL ORGANS, 2016, 40 (06) : 549 - 560