Photoplethysmography for an independent measure of pulsatile pressure under controlled flow conditions

被引:7
|
作者
Njoum, Haneen [1 ]
Kyriacou, Panayiotis A. [1 ]
机构
[1] City Univ London, Biomed Engn Res Ctr, London EC1V 0HB, England
关键词
photoplethysmography; non-invasive pressure; hemodynamics; diagnostics; optical sensors; ACCURACY; DEVICE; AGREEMENT;
D O I
10.1088/1361-6579/38/2/87
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Noninvasive continuous blood pressure measurements are desirable for patients and clinicians. This work proposes and validates a method for transmural pressure measurement using photoplethysmography (PPG) in an in vitro setup that allows control of pressure and flow conditions. The optimum pulsatile volume measure is obtained by comparing parameters extracted from the photoplethysmographic signal (AC amplitude, normalized pulse volume (NPV) and adjusted pulse volume (APV)). Pulsatile volume can then provide pressure measurements using the exponential pressure-volume (P-V) relationship and validated using the gold standard catheter pressure measurement. Pressure, red (R) and infrared (IR) PPG signals were recorded continuously in two arterial models with different cross-sectional areas (Model 1 and Model 2) utilising a pulsatile pump. Flow rates were controlled by varying pumping frequencies at low and high stroke volumes. The optimum method for estimation of the pulsatile volume is through APV, which had a highly significant correlation (r(2) = 0.99, p < 0.001) for Model 1 and (r(2) = 0.98, p < 0.001) for Model 2. APV obtained a significantly better fit when compared to NPVIR (r(2) = 0.73, z = 25.85, p < 0.001), NPVR (r(2) = 0.95, z = 12.26, p < 0.001), IRAC (r(2) = 0.52, z = 28.29, p < 0.0001) and RAC (r(2) = 0.92, z = 15.27, p < 0.0001) in Model 1, and when compared to NPVIR (r(2) = 0.92, z = 10.23, p < 0.0001), NPVR (r(2) = 0.96, z = 5.08, p < 0.001) IRAC (r(2) = 0.63, z = 22.47, p < 0.0001) and R-AC (r(2) = 0.92, z = 17.70, p < 0.0001) in Model 2. These preliminary findings suggest that APV could be used as a potential non-invasive continuous method of blood pressure measurement at different flow conditions.
引用
收藏
页码:87 / 100
页数:14
相关论文
共 50 条
  • [41] Evolution of vortex structures in an open deep cavity under pulsatile flow conditions: An experimental study
    Zhang, Yan
    Eichholz, Benjamin
    Zhang, Ruihang
    PHYSICS OF FLUIDS, 2022, 34 (09)
  • [42] Color doppler velocity measurements compared with laser doppler anemometry under pulsatile flow conditions
    Weigand, CJ
    Liepsch, DW
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 1999, 27 (04) : 255 - 266
  • [43] Inverse role of pulsatile blood flow on thrombus growth under physiological and disturbed rheological conditions
    Maurer, E.
    Schaff, M.
    Cazenave, J-P
    Gachet, C.
    Lanza, F.
    Mangin, P. H.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 : 293 - 294
  • [44] Color Doppler velocity measurements compared with laser Doppler anemometry under pulsatile flow conditions
    Weigand, C.J.
    Liepsch, D.W.
    Instrumentation Science and Technology, 1999, 27 (04): : 255 - 266
  • [45] Changes in intraocular pressure and pulsatile ocular blood flow during phacoemulsification under peribulbar anaesthetic
    Constable, PH
    King, AJ
    Migdal, CS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S835 - S835
  • [46] Ultrasound-Controlled Swarmbots Under Physiological Flow Conditions
    Fonseca, Alexia Del Campo
    Kohler, Tobias
    Ahmed, Daniel
    ADVANCED MATERIALS INTERFACES, 2022, 9 (26):
  • [47] Unsteady Character and Flow Fields in an Axial Blood Pump under Pulsatile Pressure Boundary Condition
    Wang, Mengyu
    Xu, Han
    Jin, Donghai
    Gui, Xingmin
    2018 2ND INTERNATIONAL CONFERENCE ON ADVANCED TECHNOLOGIES IN DESIGN, MECHANICAL AND AERONAUTICAL ENGINEERING (ATDMAE 2018), 2018, 408
  • [48] Flow experience in a computer game under experimentally controlled conditions
    Rheinberg, F
    Vollmeyer, R
    ZEITSCHRIFT FUR PSYCHOLOGIE-JOURNAL OF PSYCHOLOGY, 2003, 211 (04): : 161 - 170
  • [49] Flow visualisation in a geotechnical centrifuge under controlled seepage conditions
    Beckett, C. T. S.
    Fourie, A. B.
    PHYSICAL MODELLING IN GEOTECHNICS, VOL 2, 2018, : 823 - 828
  • [50] Flow characteristics past jellyfish and St. Vincent valves in the aortic position under physiological pulsatile flow conditions
    Morsi, YS
    Sakhaeimanesh, AA
    ARTIFICIAL ORGANS, 2000, 24 (07) : 564 - 574