Computing pulsatile blood flow of coronary artery under incomplete boundary conditions

被引:3
|
作者
Pu, WenJun [1 ]
Chen, Yan [2 ]
Zhao, Shuai [3 ]
Yu, Tiantong [4 ]
Lin, Heqiang [1 ]
Gao, Haokao [4 ]
Xie, Songyun [1 ]
Zhang, Xi [5 ]
Zhang, Bohui [6 ]
Li, Chengxiang [4 ]
Lian, Kun [4 ]
Xie, Xinzhou [1 ]
机构
[1] Northwestern Polytech Univ, Sch Elect & Informat, Dept Informat Engn, 1 Dongxiang Rd, Xian 710129, Shaanxi, Peoples R China
[2] 971 Hosp PLA Navy, Dept Cardiol, Qingdao, Shandong, Peoples R China
[3] Air Force Hosp Western Theater Command, Dept Cardiol, Chengdu, Sichuan, Peoples R China
[4] Forth Mil Med Univ, Xijing Hosp, Dept Cardiol, 169 West Changle Rd, Xian 710032, Shaanxi, Peoples R China
[5] Xijing Hosp, Dept Cardiol, Changle West Rd, Xian, Shaanxi, Peoples R China
[6] Shaanxi Univ Chinese Med, Sch Publ Hlth, Xian, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Coronary artery disease; Pulsatile coronary blood flow; Hemodynamic; Computational fluid dynamic; TIMI FRAME COUNT; PRESSURE; WIRE;
D O I
10.1016/j.medengphy.2024.104193
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Accurate measurement of pulsatile blood flow in the coronary arteries enables coronary wave intensity analysis, which can serve as an indicator for assessing coronary artery physiology and myocardial viability. Computational fluid dynamics (CFD) methods integrating coronary angiography images and fractional flow reserve (FFR) offer a novel approach for computing mean coronary blood flow. However, previous methods neglect the inertial effect of blood flow, which may have great impact on pulsatile blood flow calculation. To improve the accuracy of pulsatile blood flow calculation, a novel CFD based method considering the inertia term is proposed. Methods: A flow resistance model based on Pressure-Flow vs.Time curves is proposed to model the resistance of the epicardial artery. The parameters of the flow resistance model can be fitted from the simulated pulsating flow rates and pressure drops of a specific mode. Then, pulsating blood flow can be calculated by combining the incomplete pressure boundary conditions under pulsating conditions which are easily obtained in clinic. Through simulation experiments, the effectiveness of the proposed method is validated in idealized and reconstructed 3D model of coronary artery. The impacts of key parameters for generating the simulated pulsating flow rates and pressure drops on the accuracy of pulsatile blood flow calculation are also investigated. Results: For the idealized model, the previously proposed Pressure-Flow model has a significant leading effect on the computed blood flow waveform in the moderate model, and this leading effect disappears with the increase of the degree of stenosis. The improved model proposed in this paper has no leading effect, the root mean square error (RMSE) of the proposed model is low (the left coronary mode:<= 0.0160, the right coronary mode:<= 0.0065) for all simulated models, and the RMSE decreases with an increase of stenosis. The RMSE is consistently small (<= 0.0217) as the key parameters of the proposed method vary in a large range. It is verified in the reconstructed model that the proposed model significantly reduces the RMSE of patients with moderate stenosis (the PressureFlow model:<= 0.0683, the Pressure-Flow vs.Time model:<= 0.0297), and the obtained blood flow waveform has a higher coincidence with the simulated reference waveform. Conclusions: This paper confirms that ignoring the effect of inertia term can significantly affect the accuracy of calculating pulsatile blood flow in moderate stenosis lesions, and the new method proposed in this paper can significantly improves the accuracy of calculating pulsatile blood flow in moderate stenosis lesions. The proposed method provides a convenient clinical method for obtaining pressure-synchronized blood flow, which is expected to facilitate the application of waveform analysis in the diagnosis of coronary artery disease.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Computing intracoronary blood flow rate under incomplete boundary conditions: Combing coronary anatomy and fractional flow reserve
    Li, Weihao
    Lian, Kun
    Chen, Yan
    Zhao, Shuai
    Guo, Xiaoqiong
    Tao, Qian
    Gao, Haokao
    Xie, Songyun
    Li, Chengxiang
    Wang, Qiong
    Xie, Xinzhou
    MEDICAL ENGINEERING & PHYSICS, 2023, 111
  • [2] The Effect of Blood Rheology and Inlet Boundary Conditions on Realistic Abdominal Aortic Aneurysms under Pulsatile Flow Conditions
    Tzirakis, Konstantinos
    Kamarianakis, Yiannis
    Kontopodis, Nikolaos
    Ioannou, Christos V. V.
    BIOENGINEERING-BASEL, 2023, 10 (02):
  • [3] Pulsatile flow in the human left coronary artery bifurcation: Average conditions
    He, XJ
    Ku, DN
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (01): : 74 - 82
  • [4] Simulation of Pulsatile flow of blood in stenosed coronary artery bypass with graft
    Wiwatanapataphee, B
    Poltem, D
    Wu, YH
    Lenbury, Y
    MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2006, 3 (02) : 371 - 383
  • [5] Pulsatile Aortic Blood Flow-A Critical Assessment of Boundary Conditions
    Fuchs, Alexander
    Berg, Niclas
    Prahl Wittberg, Lisa
    Journal of Engineering and Science in Medical Diagnostics and Therapy, 2021, 4 (01)
  • [6] An automated and time-efficient framework for simulation of coronary blood flow under steady and pulsatile conditions
    Nannini, Guido
    Saitta, Simone
    Mariani, Luca
    Maragna, Riccardo
    Baggiano, Andrea
    Mushtaq, Saima
    Pontone, Gianluca
    Redaelli, Alberto
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2024, 257
  • [7] Pulsatile flow of thixotropic blood in artery under external body acceleration
    Cheffar, Louiza
    Benslimane, Abdelhakim
    Sadaoui, Djamel
    Benchabane, Adel
    Bekkour, Karim
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2023, 26 (08) : 927 - 940
  • [9] Effect of magnetic field on temperature distribution of atherosclerotic plaques in coronary artery under pulsatile blood flow condition
    Ghaffari, S.
    Alizadeh, S.
    Karimi, M. S.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2013, 64 : 40 - 52
  • [10] Influence of model boundary conditions on blood flow patterns in a patient specific stenotic right coronary artery
    Biyue Liu
    Jie Zheng
    Richard Bach
    Dalin Tang
    BioMedical Engineering OnLine, 14