Computing pulsatile blood flow of coronary artery under incomplete boundary conditions

被引:3
|
作者
Pu, WenJun [1 ]
Chen, Yan [2 ]
Zhao, Shuai [3 ]
Yu, Tiantong [4 ]
Lin, Heqiang [1 ]
Gao, Haokao [4 ]
Xie, Songyun [1 ]
Zhang, Xi [5 ]
Zhang, Bohui [6 ]
Li, Chengxiang [4 ]
Lian, Kun [4 ]
Xie, Xinzhou [1 ]
机构
[1] Northwestern Polytech Univ, Sch Elect & Informat, Dept Informat Engn, 1 Dongxiang Rd, Xian 710129, Shaanxi, Peoples R China
[2] 971 Hosp PLA Navy, Dept Cardiol, Qingdao, Shandong, Peoples R China
[3] Air Force Hosp Western Theater Command, Dept Cardiol, Chengdu, Sichuan, Peoples R China
[4] Forth Mil Med Univ, Xijing Hosp, Dept Cardiol, 169 West Changle Rd, Xian 710032, Shaanxi, Peoples R China
[5] Xijing Hosp, Dept Cardiol, Changle West Rd, Xian, Shaanxi, Peoples R China
[6] Shaanxi Univ Chinese Med, Sch Publ Hlth, Xian, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Coronary artery disease; Pulsatile coronary blood flow; Hemodynamic; Computational fluid dynamic; TIMI FRAME COUNT; PRESSURE; WIRE;
D O I
10.1016/j.medengphy.2024.104193
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Accurate measurement of pulsatile blood flow in the coronary arteries enables coronary wave intensity analysis, which can serve as an indicator for assessing coronary artery physiology and myocardial viability. Computational fluid dynamics (CFD) methods integrating coronary angiography images and fractional flow reserve (FFR) offer a novel approach for computing mean coronary blood flow. However, previous methods neglect the inertial effect of blood flow, which may have great impact on pulsatile blood flow calculation. To improve the accuracy of pulsatile blood flow calculation, a novel CFD based method considering the inertia term is proposed. Methods: A flow resistance model based on Pressure-Flow vs.Time curves is proposed to model the resistance of the epicardial artery. The parameters of the flow resistance model can be fitted from the simulated pulsating flow rates and pressure drops of a specific mode. Then, pulsating blood flow can be calculated by combining the incomplete pressure boundary conditions under pulsating conditions which are easily obtained in clinic. Through simulation experiments, the effectiveness of the proposed method is validated in idealized and reconstructed 3D model of coronary artery. The impacts of key parameters for generating the simulated pulsating flow rates and pressure drops on the accuracy of pulsatile blood flow calculation are also investigated. Results: For the idealized model, the previously proposed Pressure-Flow model has a significant leading effect on the computed blood flow waveform in the moderate model, and this leading effect disappears with the increase of the degree of stenosis. The improved model proposed in this paper has no leading effect, the root mean square error (RMSE) of the proposed model is low (the left coronary mode:<= 0.0160, the right coronary mode:<= 0.0065) for all simulated models, and the RMSE decreases with an increase of stenosis. The RMSE is consistently small (<= 0.0217) as the key parameters of the proposed method vary in a large range. It is verified in the reconstructed model that the proposed model significantly reduces the RMSE of patients with moderate stenosis (the PressureFlow model:<= 0.0683, the Pressure-Flow vs.Time model:<= 0.0297), and the obtained blood flow waveform has a higher coincidence with the simulated reference waveform. Conclusions: This paper confirms that ignoring the effect of inertia term can significantly affect the accuracy of calculating pulsatile blood flow in moderate stenosis lesions, and the new method proposed in this paper can significantly improves the accuracy of calculating pulsatile blood flow in moderate stenosis lesions. The proposed method provides a convenient clinical method for obtaining pressure-synchronized blood flow, which is expected to facilitate the application of waveform analysis in the diagnosis of coronary artery disease.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Numerical Investigation of Pulsatile Blood Flow in Stenosed Artery
    Haghighi A.R.
    Kabdool A.A.
    Asl M.S.
    kiyasatfar M.
    International Journal of Applied and Computational Mathematics, 2016, 2 (4) : 649 - 662
  • [22] PULSATILE BLOOD-FLOW IN A POROUS STENOTIC ARTERY
    CHAKRAVARTY, S
    DATTA, A
    MATHEMATICAL AND COMPUTER MODELLING, 1992, 16 (02) : 35 - 54
  • [23] Pulsatile Flow of Blood in a Constricted Artery with Body Acceleration
    Biswas, Devajyoti
    Chakraborty, Uday Shankar
    APPLICATIONS AND APPLIED MATHEMATICS-AN INTERNATIONAL JOURNAL, 2009, 4 (02): : 329 - 342
  • [24] ITERATIVE SOLUTION FOR PULSATILE FLOW OF BLOOD THROUGH AN ARTERY
    Maity, A. K.
    JOURNAL OF MECHANICS OF CONTINUA AND MATHEMATICAL SCIENCES, 2008, 3 (01): : 192 - 210
  • [25] The effects of pulsatile versus non-pulsatile extracorporeal circulation on the pattern of coronary artery blood flow during cardiac arrest
    Son, HS
    Sun, K
    Fang, YH
    Park, SY
    Hwang, CM
    Park, SM
    Lee, SH
    Kim, KT
    Lee, IS
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (06): : 609 - 616
  • [26] Haemodynamic analysis of coronary artery bypass grafting in a non-linear deformable artery and Newtonian pulsatile blood flow
    Kouhi, E.
    Morsi, Y.S.
    Masood, S.H.
    Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2008, 222 (08) : 1273 - 1287
  • [27] Haemodynamic analysis of coronary artery bypass grafting in a non-linear deformable artery and Newtonian pulsatile blood flow
    Kouhi, E.
    Morsi, Y. S.
    Masood, S. H.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2008, 222 (H8) : 1273 - 1287
  • [28] Haemodynamic analysis of coronary artery bypass grafting in a non-linear deformable artery and Newtonian pulsatile blood flow
    Faculty of Engineering and Industrial Sciences, Swinburne University of Technology, P.O Box 218, Hawthorn
    VIC
    3122, Australia
    Proc. Inst. Mech. Eng. Part H J. Eng. Med., 2008, 8 (1273-1287):
  • [29] Pulsatile flow in a coronary artery using multiphase kinetic theory
    Huang, Jing
    Lyczkowski, Robert W.
    Gidaspow, Dimitri
    JOURNAL OF BIOMECHANICS, 2009, 42 (06) : 743 - 754
  • [30] Unsteady Character and Flow Fields in an Axial Blood Pump under Pulsatile Pressure Boundary Condition
    Wang, Mengyu
    Xu, Han
    Jin, Donghai
    Gui, Xingmin
    2018 2ND INTERNATIONAL CONFERENCE ON ADVANCED TECHNOLOGIES IN DESIGN, MECHANICAL AND AERONAUTICAL ENGINEERING (ATDMAE 2018), 2018, 408