Stereotactic body radiation therapy patient specific quality assurance using a two-dimensional array at extended source to surface distance

被引:0
|
作者
Stathakis, Sotirios [1 ]
Mavroidis, Panayiotis [1 ]
Narayanasamy, Ganesh [1 ]
Markovic, Miljenko [1 ]
Myers, Pamela [2 ]
Papanikolaou, Niko [1 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, Dept Radiat Oncol, San Antonio, TX 78229 USA
[2] Baylor Coll Med, Dept Radiat Oncol, Houston, TX 77030 USA
来源
JOURNAL OF BUON | 2015年 / 20卷 / 04期
关键词
DQA; IMRT; measurements at extended SSD; SBRT; ION-CHAMBER ARRAY; IMRT DOSE VERIFICATION; SPATIAL-RESOLUTION; BEAMS; RADIOTHERAPY; PHOTON; DOSIMETRY; DETECTOR; SIZE; FILM;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Methods: Five patients with 38 fields have been analyzed in this study. The plans were optimized for the following clinical sites: one. liver, one lung, one brain, one prostate aiid one spine. The detector array used for the measurements was the PTW Seven29 array. All the plans were optimized and calculated using Eclipse v8.9. The center of the array was setup at 215 cm from the source and all the fields were measured and analyzed one by one. All the 30 measurements were performed on a NovalisTX linear accelerator equipped with a high definition multileaf collimator. The evaluation was based mainly on gamma index passing rates using 2 mm distance to agreement (DTA) and 2% dose difference. Results: The accuracy of the Eclipse Treatment Planning System (TPS) at extended Source to Surface Distances (SSDs) using an ionization chamber was measured to be within 1.0%. All the field measurements were performed and analyzed 35. individually. The percent of the points that had a gamma index of less than 1 using 3%/3 mm was >99% for all the measurements. In order to better evaluate our process and distinguish smaller differences a new set of results was obtained by applying gamma index tolerances of 2%/2mm. In this case, the gamma index passing rates ranged from 90.8 to 100% (95.5%+/- 3%). The profile comparison showed that the detector array measurements followed closely the calculated 40 profiles, even for fields optimized with multiple peaks and valleys. Conclusion: The choice of the IMRT QA device has an important role in the results of the patient specific QA of the delivered dose to the patient in the case of small targets as in the treatment of spinal targets. In this study, we demonstrated that an extended SSD measurement can improve the sampling resolution of a two-dimensional (2D) detector array, in our case the PTW 45 Seven29 array. This method was shown to be accurate and efficient for measuring highly modulated small fields for pre-treatment patient specific QA.
引用
收藏
页码:1154 / 1163
页数:10
相关论文
共 50 条
  • [31] Assessing the suitability of a two-dimensional array for routine quality assurance checks of flatness and symmetry
    Salma Ibrahim
    Venkatakrishnan Seshadri
    Paul Charles
    Physical and Engineering Sciences in Medicine, 2020, 43 : 1451 - 1460
  • [32] Quality Assurance of Deformation Algorithms Using a Two-Dimensional Deformable Phantom
    Kirby, N.
    Chuang, C.
    Pouliot, J.
    MEDICAL PHYSICS, 2011, 38 (06) : 3821 - +
  • [33] Use of a novel two-dimensional ionization chamber array for pencil beam scanning proton therapy beam quality assurance
    Lin, Liyong
    Kang, Minglei
    Solberg, Timothy D.
    Mertens, Thierry
    Baumer, Christian
    Ainsley, Christopher G.
    McDonough, James E.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 270 - 276
  • [34] Patient-specific motion and treatment margins in pancreatic stereotactic body radiation therapy
    Miften, M.
    Jones, B. L.
    Fukami, N.
    Schefter, T.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S198 - S199
  • [35] Development of a High-Resolution End-to-End Patient-Specific Quality Assurance Tool for Rotational Stereotactic Body Radiation Therapy Deliveries Using an Electronic Portal Imaging Device
    Yang, Y.
    Han, B.
    Xing, L.
    Wang, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E605 - E605
  • [36] Patient-Specific Quality Assurance in Pencil Beam Scanning by 2-Dimensional Array
    Rawiwan, Nuttida
    Chatchumnan, Nichakan
    Vimolnoch, Mananchaya
    Kingkaew, Sakda
    Oonsiri, Sornjarod
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2023, 10 (02) : 105 - 110
  • [37] Radiation modelling of arbitrary two-dimensional surfaces using the surface-to-surface approach extended with a blocking algorithm
    Dominik Büschgens
    Christian Schubert
    Herbert Pfeifer
    Heat and Mass Transfer, 2022, 58 : 1637 - 1648
  • [38] Radiation modelling of arbitrary two-dimensional surfaces using the surface-to-surface approach extended with a blocking algorithm
    Bueschgens, Dominik
    Schubert, Christian
    Pfeifer, Herbert
    HEAT AND MASS TRANSFER, 2022, 58 (09) : 1637 - 1648
  • [39] Analysis of dose comparison techniques for patient-specific quality assurance in radiation therapy
    Yu, Liting
    Tang, Timothy L. S.
    Cassim, Naasiha
    Livingstone, Alexander
    Cassidy, Darren
    Kairn, Tanya
    Crowe, Scott B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (11): : 189 - 198
  • [40] Comparative study of two patient immobilisation devices for lung stereotactic body radiation therapy
    Boisbouvier, S.
    Lafay, I. Martel
    Ayadi, M. Zahra
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1639 - S1639