Stereotactic body radiation therapy patient specific quality assurance using a two-dimensional array at extended source to surface distance

被引:0
|
作者
Stathakis, Sotirios [1 ]
Mavroidis, Panayiotis [1 ]
Narayanasamy, Ganesh [1 ]
Markovic, Miljenko [1 ]
Myers, Pamela [2 ]
Papanikolaou, Niko [1 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, Dept Radiat Oncol, San Antonio, TX 78229 USA
[2] Baylor Coll Med, Dept Radiat Oncol, Houston, TX 77030 USA
来源
JOURNAL OF BUON | 2015年 / 20卷 / 04期
关键词
DQA; IMRT; measurements at extended SSD; SBRT; ION-CHAMBER ARRAY; IMRT DOSE VERIFICATION; SPATIAL-RESOLUTION; BEAMS; RADIOTHERAPY; PHOTON; DOSIMETRY; DETECTOR; SIZE; FILM;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Methods: Five patients with 38 fields have been analyzed in this study. The plans were optimized for the following clinical sites: one. liver, one lung, one brain, one prostate aiid one spine. The detector array used for the measurements was the PTW Seven29 array. All the plans were optimized and calculated using Eclipse v8.9. The center of the array was setup at 215 cm from the source and all the fields were measured and analyzed one by one. All the 30 measurements were performed on a NovalisTX linear accelerator equipped with a high definition multileaf collimator. The evaluation was based mainly on gamma index passing rates using 2 mm distance to agreement (DTA) and 2% dose difference. Results: The accuracy of the Eclipse Treatment Planning System (TPS) at extended Source to Surface Distances (SSDs) using an ionization chamber was measured to be within 1.0%. All the field measurements were performed and analyzed 35. individually. The percent of the points that had a gamma index of less than 1 using 3%/3 mm was >99% for all the measurements. In order to better evaluate our process and distinguish smaller differences a new set of results was obtained by applying gamma index tolerances of 2%/2mm. In this case, the gamma index passing rates ranged from 90.8 to 100% (95.5%+/- 3%). The profile comparison showed that the detector array measurements followed closely the calculated 40 profiles, even for fields optimized with multiple peaks and valleys. Conclusion: The choice of the IMRT QA device has an important role in the results of the patient specific QA of the delivered dose to the patient in the case of small targets as in the treatment of spinal targets. In this study, we demonstrated that an extended SSD measurement can improve the sampling resolution of a two-dimensional (2D) detector array, in our case the PTW 45 Seven29 array. This method was shown to be accurate and efficient for measuring highly modulated small fields for pre-treatment patient specific QA.
引用
收藏
页码:1154 / 1163
页数:10
相关论文
共 50 条
  • [41] End-to-End Quality Assurance of Stereotactic Radiation Therapy Using an Anthropomorphic Head Phantom
    Alexander, Km
    Dekker, Kh
    Olding, T.
    Schreiner, Lj
    11TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, IC3DDOSE, 2022, 2167
  • [42] Quality assurance in IMRT: A comparison between two-dimensional ionization chamber array and film dosimetry
    Seguro Fernandez, A.
    Urena Llinares, A.
    Ramos Caballero, L. J.
    Castro Ramirez, I.
    Quinones Rodriguez, L. A.
    Mora Melendez, R.
    Angulo Pain, E.
    Iborra Oquendo, M. A.
    EUROPEAN JOURNAL OF CANCER, 2013, 49 : S230 - S230
  • [43] Dosimetric IMRT plan verification and daily quality assurance with a two-dimensional ionization chamber array
    Poppe, B
    Blechschmidt, A
    Djouguela, A
    Kollhoff, R
    Rubach, A
    Harder, D
    Schuele, E
    MEDICAL PHYSICS, 2005, 32 (06) : 1982 - 1982
  • [44] Verifying institutionally developed hybrid 3D-printed coaxial cylindrical phantom for patient-specific quality assurance in stereotactic body radiation therapy of hepatocellular carcinoma
    Krishnan, M. P. Arun
    Momeen, M. Ummal
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (01) : 230 - 237
  • [45] Verifying institutionally developed hybrid 3D-printed coaxial cylindrical phantom for patient-specific quality assurance in stereotactic body radiation therapy of hepatocellular carcinoma
    M. P. Arun Krishnan
    M. Ummal Momeen
    Radiological Physics and Technology, 2024, 17 : 230 - 237
  • [46] Development of pretreatment 'truly' patient-specific quality assurance procedure for stereotactic body radiotherapy using volumetric modulated arc radiotherapy
    Tachiiri, S.
    Tanaka, K.
    Tanaka, K.
    Yanagawa, M.
    Kosuga, T.
    Onishi, Y.
    Miyai, A.
    Otsu, S.
    EUROPEAN JOURNAL OF CANCER, 2013, 49 : S229 - S229
  • [47] A Novel High-Resolution Quality Assurance Phantom System for Modulated Arc Stereotactic Body Radiation Therapy
    Knewtson, T.
    Wiles, A.
    Brink, K.
    Izaguirre, E. W.
    MEDICAL PHYSICS, 2017, 44 (06) : 2957 - 2957
  • [48] Patient-Specific Rectal Toxicity Predictor Based Plan Quality Control for Prostate Stereotactic Body Radiation Therapy (SBRT)
    Song, T.
    Li, Y.
    Zhou, L.
    Jiang, S.
    Gu, X.
    MEDICAL PHYSICS, 2015, 42 (06) : 3211 - 3211
  • [49] Application of Optical Surface Monitoring System in Stereotactic Body Radiation Therapy for Liver Metastases Patient
    Zhang, R.
    Jiang, H.
    Xu, W.
    Qin, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 114 (03): : E184 - E184
  • [50] Magnetic source parameters of two-dimensional structures using extended Euler deconvolution
    Mushayandebvu, MF
    van Driel, P
    Reid, AB
    Fairhead, JD