Optical coherence tomography-derived corneal thickness asymmetry indices: Clinical reference study of normal eyes

被引:12
|
作者
Kanellopoulos, Anastasios John [1 ,2 ]
Chiridou, Marianthi [1 ]
Asimellis, George [1 ]
机构
[1] Laservis Gr Clin & Res Inst, Athens 11521, Greece
[2] NYU, Sch Med, New York, NY USA
来源
关键词
HIGH-SPEED; IN-VIVO; SWEPT-SOURCE; KERATOCONUS; PACHYMETRY; RESOLUTION; OCT; REPEATABILITY; ULTRASOUND;
D O I
10.1016/j.jcrs.2014.01.041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine 3-dimensional corneal pachymetry distribution characteristics in a large pool of healthy normal patients. SETTING: Private practice, Athens, Greece. DESIGN: Prospective case series. METHODS: Spectral-domain anterior segment optical coherence tomography (AS-OCT) was used for measurements of central (CCT) and minimum corneal thickness, thickness asymmetry indices for superonasal-inferotemporal (SN-IT) and superior-inferior (S-I), and focal thinning indices (Min-Med focal thinning, Min-Max thickness range). RESULTS: The study enrolled 561 eyes. The mean values were CCT, 537.17 mu m +/- 30.99 (SD) (range 447.0 to 654.0 mu m); minimum corneal thickness, 529.01 +/- 30.02 mu m (range 435.0 to 644.0 mu m); SN-IT, 26.32 +/- 15.06 mu m (range -23.0 to 97.0 mu m); S-I, 25.34 +/- 15.06 mu m (range -36.0 to 93.0 mu m); Min-Med, -20.70 +/- 5.99 mu m (range -7.0 to -50.0 mu m); Min-Max, -59.79 +/- 16.55 mu m (range -156.0 to -23.0 mu m). There were significant age-related differences; the mean SN-IT was 22.19 +/- 12.40 mu m (range -6.0 to 63.0 mu m) in the younger group and 30.44 +/- 15.07 mu m (range -4.0 to 97.0 mu m) in the older group (P=.002). The mean S-I was 21.47 +/- 12.92 mu m (range -5.0 to 70.0 mu m) and 29.76 +/- 16.27 mu m (range -8.0 to 93.0 mu m), respectively (P=.001). CONCLUSIONS: Corneal-thickness asymmetry distribution in a healthy eye population obtained by Fourier-domain AS-OCT showed increased asymmetry in the older group; the asymmetry was not sex dependent. These findings may provide a benchmark for future comparative studies.
引用
收藏
页码:1603 / 1609
页数:7
相关论文
共 50 条
  • [41] Assessment of central corneal thickness using optical coherence tomography
    Fishman, GR
    Pons, ME
    Seedor, JA
    Liebmann, JM
    Ritch, R
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (04): : 707 - 711
  • [42] Repeatability and reproducibility of corneal thickness measurements by optical coherence tomography
    Muscat, S
    McKay, N
    Parks, S
    Kemp, E
    Keating, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 (06) : 1791 - 1795
  • [43] Corneal layer thickness in keratoconus using optical coherence tomography
    Heidari, Zahra
    Mohammadpour, Mehrdad
    Hajizadeh, Fedra
    Fotouhi, Akbar
    Hashemi, Hassan
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2024, 107 (01) : 32 - 39
  • [44] The effect of oxybuprocaine on corneal thickness as measured with optical coherence tomography
    Govender, Rowen
    Seedat, Zainab Y.
    Ramdass, Aristha
    Hansraj, Rekha
    Gcabashe, Nonkululeko M.
    AFRICAN VISION AND EYE HEALTH JOURNAL, 2016, 75 (01):
  • [45] Corneal and corneal epithelial thickness distribution characteristics in healthy North Indian eyes using spectral domain optical coherence tomography
    Malhotra, Chintan
    Gupta, Barkha
    Dhiman, Rajneesh
    Jain, Arun K.
    Gupta, Amit
    Ram, Jagat
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (04) : 1171 - 1178
  • [46] Impact of rigid gas-permeable contact lens on keratometric indices and corneal thickness of keratoconus eyes examined with anterior segment optical coherence tomography
    Akiyama, Kaho
    Ono, Takashi
    Ishii, Hitoha
    Chen, Lily Wei
    Kitamoto, Kohdai
    Toyono, Tetsuya
    Yoshida, Junko
    Aihara, Makoto
    Miyai, Takashi
    PLOS ONE, 2022, 17 (05):
  • [47] Impact of rigid gas-permeable contact lens on keratometric indices and corneal thickness of keratoconus eyes examined with anterior segment optical coherence tomography
    Akiyama, Kaho
    Ono, Takashi
    Ishii, Hitoha
    Chen, Lily Wei
    Kitamoto, Kohdai
    Toyono, Tetsuya
    Yoshida, Junko
    Aihara, Makoto
    Miyai, Takashi
    PLOS ONE, 2022, 17 (07):
  • [48] The repeatability of corneal and corneal epithelial thickness measurements using optical coherence tomography
    Sin, Sokpheaktra
    Simpson, Trefford L.
    OPTOMETRY AND VISION SCIENCE, 2006, 83 (06) : 360 - 365
  • [49] Clinical diversity in macular corneal dystrophy: an optical coherence tomography study
    Sunita Chaurasia
    Muralidhar Ramappa
    Dilip Kumar Mishra
    International Ophthalmology, 2019, 39 : 2883 - 2888
  • [50] Retinal nerve fiber layer thickness in normal, ocular hypertensive, and glaucomatous Indian eyes - An optical coherence tomography study
    Gyatsho, Jamyang
    Kaushik, Sushmita
    Gupta, Amod
    Pandav, Surinder Singh
    Ram, Jagat
    JOURNAL OF GLAUCOMA, 2008, 17 (02) : 122 - 127