Optical coherence tomography-derived corneal thickness asymmetry indices: Clinical reference study of normal eyes

被引:12
|
作者
Kanellopoulos, Anastasios John [1 ,2 ]
Chiridou, Marianthi [1 ]
Asimellis, George [1 ]
机构
[1] Laservis Gr Clin & Res Inst, Athens 11521, Greece
[2] NYU, Sch Med, New York, NY USA
来源
关键词
HIGH-SPEED; IN-VIVO; SWEPT-SOURCE; KERATOCONUS; PACHYMETRY; RESOLUTION; OCT; REPEATABILITY; ULTRASOUND;
D O I
10.1016/j.jcrs.2014.01.041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine 3-dimensional corneal pachymetry distribution characteristics in a large pool of healthy normal patients. SETTING: Private practice, Athens, Greece. DESIGN: Prospective case series. METHODS: Spectral-domain anterior segment optical coherence tomography (AS-OCT) was used for measurements of central (CCT) and minimum corneal thickness, thickness asymmetry indices for superonasal-inferotemporal (SN-IT) and superior-inferior (S-I), and focal thinning indices (Min-Med focal thinning, Min-Max thickness range). RESULTS: The study enrolled 561 eyes. The mean values were CCT, 537.17 mu m +/- 30.99 (SD) (range 447.0 to 654.0 mu m); minimum corneal thickness, 529.01 +/- 30.02 mu m (range 435.0 to 644.0 mu m); SN-IT, 26.32 +/- 15.06 mu m (range -23.0 to 97.0 mu m); S-I, 25.34 +/- 15.06 mu m (range -36.0 to 93.0 mu m); Min-Med, -20.70 +/- 5.99 mu m (range -7.0 to -50.0 mu m); Min-Max, -59.79 +/- 16.55 mu m (range -156.0 to -23.0 mu m). There were significant age-related differences; the mean SN-IT was 22.19 +/- 12.40 mu m (range -6.0 to 63.0 mu m) in the younger group and 30.44 +/- 15.07 mu m (range -4.0 to 97.0 mu m) in the older group (P=.002). The mean S-I was 21.47 +/- 12.92 mu m (range -5.0 to 70.0 mu m) and 29.76 +/- 16.27 mu m (range -8.0 to 93.0 mu m), respectively (P=.001). CONCLUSIONS: Corneal-thickness asymmetry distribution in a healthy eye population obtained by Fourier-domain AS-OCT showed increased asymmetry in the older group; the asymmetry was not sex dependent. These findings may provide a benchmark for future comparative studies.
引用
收藏
页码:1603 / 1609
页数:7
相关论文
共 50 条
  • [21] Choroidal Thickness in Normal Eyes Measured Using Cirrus HD Optical Coherence Tomography
    Manjunath, Varsha
    Taha, Mohammad
    Fujimoto, James G.
    Duker, Jay S.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 150 (03) : 325 - 329
  • [22] Normal macular thickness measurements in healthy eyes using stratus optical coherence tomography
    Chan, A
    Duker, JS
    Ko, TH
    Fujimoto, JG
    Schuman, JS
    ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (02) : 193 - 198
  • [23] Comparison of Retinal Thickness in Normal Eyes Using Stratus and Spectralis Optical Coherence Tomography
    Grover, Sandeep
    Murthy, Ravi K.
    Brar, Vikram S.
    Chalam, Kakarla V.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (05) : 2644 - 2647
  • [24] OCT-Derived Comparison of Corneal Thickness Distribution and Asymmetry Differences Between Normal and Keratoconic Eyes
    Kanellopoulos, Anastasios J.
    Asimellis, George
    CORNEA, 2014, 33 (12) : 1274 - 1281
  • [25] Scanning laser polarimetry with variable corneal compensation and optical coherence tomography in normal and glaucomatous eyes
    Bagga, H
    Greenfield, DS
    Feuer, W
    Knighton, RW
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (04) : 521 - 529
  • [26] Scanning laser polarimetry with enhanced corneal compensation and optical coherence tomography in normal and glaucomatous eyes
    Sehi, Mitra
    Ume, Stephen
    Greenfield, David S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (05) : 2099 - 2104
  • [27] Scanning laser polarimetry with variable corneal compensation and optical coherence tomography in normal and glaucomatous eyes
    Brockman, ME
    Bagga, H
    Greenfield, DS
    Knighton, RW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U51 - U51
  • [28] Investigation of the Sectorized Corneal Thickness of Eyes With Corneal Endothelial Dysfunction Using Anterior-Segment Optical Coherence Tomography
    Omoto, Takashi
    Kim, Minjae
    Goto, Hiroki
    Abe, Yuito
    Ono, Takashi
    Taketani, Yukako
    Toyono, Tetsuya
    Yoshida, Junko
    Usui, Tomohiko
    Yamagami, Satoru
    Aihara, Makoto
    Miyai, Takashi
    CORNEA, 2023, 42 (06) : 714 - 718
  • [29] Clinical impact of a new optical coherence tomography-derived volumetric method for evaluating stent expansion
    Akito Kawamura
    Daisuke Nakamura
    Ryu Shutta
    Hitoshi Nakamura
    Yutaka Matsuhiro
    Naotaka Okamoto
    Yasuyuki Egami
    Yasushi Sakata
    Masami Nishino
    Jun Tanouchi
    The International Journal of Cardiovascular Imaging, 2021, 37 : 1121 - 1129
  • [30] Clinical impact of a new optical coherence tomography-derived volumetric method for evaluating stent expansion
    Kawamura, Akito
    Nakamura, Daisuke
    Shutta, Ryu
    Nakamura, Hitoshi
    Matsuhiro, Yutaka
    Okamoto, Naotaka
    Egami, Yasuyuki
    Sakata, Yasushi
    Nishino, Masami
    Tanouchi, Jun
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (04): : 1121 - 1129