Optical coherence tomography-derived corneal thickness asymmetry indices: Clinical reference study of normal eyes

被引:12
|
作者
Kanellopoulos, Anastasios John [1 ,2 ]
Chiridou, Marianthi [1 ]
Asimellis, George [1 ]
机构
[1] Laservis Gr Clin & Res Inst, Athens 11521, Greece
[2] NYU, Sch Med, New York, NY USA
来源
关键词
HIGH-SPEED; IN-VIVO; SWEPT-SOURCE; KERATOCONUS; PACHYMETRY; RESOLUTION; OCT; REPEATABILITY; ULTRASOUND;
D O I
10.1016/j.jcrs.2014.01.041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine 3-dimensional corneal pachymetry distribution characteristics in a large pool of healthy normal patients. SETTING: Private practice, Athens, Greece. DESIGN: Prospective case series. METHODS: Spectral-domain anterior segment optical coherence tomography (AS-OCT) was used for measurements of central (CCT) and minimum corneal thickness, thickness asymmetry indices for superonasal-inferotemporal (SN-IT) and superior-inferior (S-I), and focal thinning indices (Min-Med focal thinning, Min-Max thickness range). RESULTS: The study enrolled 561 eyes. The mean values were CCT, 537.17 mu m +/- 30.99 (SD) (range 447.0 to 654.0 mu m); minimum corneal thickness, 529.01 +/- 30.02 mu m (range 435.0 to 644.0 mu m); SN-IT, 26.32 +/- 15.06 mu m (range -23.0 to 97.0 mu m); S-I, 25.34 +/- 15.06 mu m (range -36.0 to 93.0 mu m); Min-Med, -20.70 +/- 5.99 mu m (range -7.0 to -50.0 mu m); Min-Max, -59.79 +/- 16.55 mu m (range -156.0 to -23.0 mu m). There were significant age-related differences; the mean SN-IT was 22.19 +/- 12.40 mu m (range -6.0 to 63.0 mu m) in the younger group and 30.44 +/- 15.07 mu m (range -4.0 to 97.0 mu m) in the older group (P=.002). The mean S-I was 21.47 +/- 12.92 mu m (range -5.0 to 70.0 mu m) and 29.76 +/- 16.27 mu m (range -8.0 to 93.0 mu m), respectively (P=.001). CONCLUSIONS: Corneal-thickness asymmetry distribution in a healthy eye population obtained by Fourier-domain AS-OCT showed increased asymmetry in the older group; the asymmetry was not sex dependent. These findings may provide a benchmark for future comparative studies.
引用
收藏
页码:1603 / 1609
页数:7
相关论文
共 50 条
  • [31] Assessment of macular retinal thickness and volume in normal eyes and highly myopic eyes with spectral optical coherence tomography
    Chebil, A.
    Ben Achour, B.
    Kort, F.
    Chaker, N.
    El Matri, L.
    ACTA OPHTHALMOLOGICA, 2013, 91
  • [32] Corneal thickness and elevation measurements using swept-source optical coherence tomography and slit scanning topography in normal and keratoconic eyes
    Jhanji, Vishal
    Yang, Bingzhi
    Yu, Marco
    Ye, Cong
    Leung, Christopher K. S.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 41 (08): : 735 - 745
  • [33] Repeatability of Corneal Epithelial Thickness Measurements Using Fourier-Domain Optical Coherence Tomography in Normal and Post-LASIK Eyes
    Ma, Xingxuan Jack
    Wang, Li
    Koch, Douglas D.
    CORNEA, 2013, 32 (12) : 1544 - 1548
  • [34] Optical coherence tomography-derived predictors of stent expansion in calcified lesions
    des Plantes, Annemieke C. Ziedses C.
    Scoccia, Alessandra
    Neleman, Tara
    Groenland, Frederik T. W.
    van Zandvoort, Laurens J. C.
    Ligthart, Jurgen M. R.
    Witberg, Karen T.
    Liu, Shengnan
    Boersma, Eric
    Nuis, Rutger-Jan
    den Dekker, Wijnand K.
    Wilschut, Jeroen
    Diletti, Roberto
    Zijlstra, Felix
    Van Mieghem, Nicolas M.
    Daemen, Joost
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2023, 102 (01) : 25 - 35
  • [35] Wide Corneal Epithelial Thickness Mapping in Eyes With Topical Antiglaucoma Therapy Using Optical Coherence Tomography
    Ye, Yiming
    Xu, Yunzhi
    Yang, Yangfan
    Fan, Yanmei
    Liu, Pingping
    Yu, Keming
    Yu, Minbin
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (01):
  • [37] Normal Macular Thickness in Healthy Indian Eyes Using Spectral Domain Optical Coherence Tomography
    Natung, Tanie
    Keditsu, Avonuo
    Lyngdoh, Laura Amanda
    Dkhar, Begonia
    Prakash, Gunjan
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2016, 5 (03): : 176 - 179
  • [38] Comparative study of central corneal thickness measurement with slit-lamp optical coherence tomography and visante optical coherence tomography
    Li, Haitao
    Leung, Christopher Kai Shun
    Wong, Lee
    Cheung, Carol Yim Lui
    Pang, Chi Pui
    Weinreb, Robert Neal
    Lam, Dennis Shun Chiu
    OPHTHALMOLOGY, 2008, 115 (05) : 796 - 801
  • [39] Reproducibility of Retinal Thickness Measurements on Normal and Pathologic Eyes by Different Optical Coherence Tomography Instruments
    Giani, Andrea
    Cigada, Mario
    Choudhry, Netan
    Deiro, Antonio Peroglio
    Oldani, Marta
    Pellegrini, Marco
    Invernizzi, Alessandro
    Duca, Piergiorgio
    Miller, Joan W.
    Staurenghi, Giovanni
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 150 (06) : 815 - 824
  • [40] Choroidal thickness in normal Indian eyes using swept-source optical coherence tomography
    Bhayana, Amber A.
    Kumar, Vinod
    Tayade, Akshay
    Chandra, Mahesh
    Chandra, Parijat
    Kumar, Atul
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (02) : 252 - 255