PURPOSE. To assess the repeatability and interoperator and intersession reproducibility of central corneal thickness (CCT) measurements made by a commercially available optical coherence tomography (OCT) system. METHODS. Intersession and interoperator reproducibility and repeatability were defined according to the guidelines of the British Standards Institution and examined in a control group of 14 normal subjects. An in-house computer program was used to evaluate central corneal thickness from these scans. RESULTS. The coefficient of interoperator reproducibility was 0.18%, whereas that for intersession reproducibility was 1.11%. Wilcoxon analysis (5% level of significance) showed that there was no statistically significant difference between scans acquired during different sessions or by different operators. Coefficients of repeatability were all less than 3%. The average CCT was 526 +/- 28 mum (SD) and the range of normal CCT between 5th and 95th percentiles was 498 to 576 mum. CONCLUSIONS. Although the commercially available OCT scanner was designed for retinal imaging, with a few minor modifications, the system may be used to image the anterior segment. Previous studies have shown that OCT measurements correlate well with those from conventional techniques, and it has the added advantage of being a noncontact technique. This study further demonstrates that the OCT measurements show a high degree of repeatability and reproducibility. Thus, OCT is emerging as a promising tool for evaluation of CCT in the clinical setting.
引用
收藏
页码:1791 / 1795
页数:5
相关论文
共 50 条
  • [1] The repeatability of corneal and corneal epithelial thickness measurements using optical coherence tomography
    Sin, Sokpheaktra
    Simpson, Trefford L.
    [J]. OPTOMETRY AND VISION SCIENCE, 2006, 83 (06) : 360 - 365
  • [2] Repeatability and Reproducibility of Slit Lamp, Optical Coherence Tomography, and Scheimpflug Measurements of Corneal Scars
    Das, Manoranjan
    Menda, Shivali A.
    Panigrahi, Arun K.
    Prajna, N. Venkatesh
    Yen, Michael
    Tsang, Betty
    Kumar, Alisha
    Rose-Nussbaumer, Jennifer
    Acharya, Nisha R.
    McCulloch, Charles E.
    Lietman, Thomas M.
    McLeod, Stephen D.
    Keenan, Jeremy D.
    [J]. OPHTHALMIC EPIDEMIOLOGY, 2019, 26 (04) : 251 - 256
  • [3] Repeatability and Reproducibility of Macular Thickness Measurements Using Fourier Domain Optical Coherence Tomography
    Bruce, Alison
    Pacey, Ian E.
    Dharni, Poonam
    Scally, Andy J.
    Barrett, Brendan T.
    [J]. OPEN OPHTHALMOLOGY JOURNAL, 2009, 3 : 10 - 14
  • [4] Repeatability of corneal and epithelial thickness measurements with anterior segment optical coherence tomography in keratoconus
    Li, Ye
    Gokul, Akilesh
    McGhee, Charles
    Ziaei, Mohammed
    [J]. PLOS ONE, 2021, 16 (06):
  • [5] Repeatability of corneal and epithelial thickness measurements with anterior segment optical coherence tomography in keratoconus
    Li, Ye
    Gokul, Akilesh
    McGhee, Charles
    Ziaei, Mo
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 49 (08): : 884 - 885
  • [6] Repeatability and Reproducibility of Retinal Thickness Measurements in Diabetic Patients with Spectral Domain Optical Coherence Tomography
    Fiore, Tito
    Androudi, Sofia
    Iaccheri, Barbara
    Lupidi, Marco
    Fabrizio, Giansanti
    Fruttini, Daniela
    Biondi, Laura
    Cagini, Carlo
    [J]. CURRENT EYE RESEARCH, 2013, 38 (06) : 674 - 679
  • [7] Repeatability and Reproducibility of Spectral-Domain Optical Coherence Tomography Measurements of Retinal Thickness in Rats
    Yang, Ji Ho
    Yu, Seung-Young
    Kim, Tae Gi
    Seo, Kyung Hoon
    Kwak, Hyung Woo
    [J]. CURRENT EYE RESEARCH, 2016, 41 (10) : 1346 - 1352
  • [8] Repeatability and Reproducibility of Retinal Thickness Measurements by Optical Coherence Tomography in Age-Related Macular Degeneration
    Krebs, Ilse
    Hagen, Stefan
    Brannath, Werner
    Haas, Paulina
    Womastek, Irene
    de Salvo, Gabriella
    Ansari-Shahrezaei, Siamak
    Binder, Susanne
    [J]. OPHTHALMOLOGY, 2010, 117 (08) : 1577 - 1584
  • [9] Repeatability and reproducibility of fast macular thickness mapping with stratus optical coherence tomography
    Polito, A
    Del Borrello, M
    Isola, M
    Zemella, N
    Bandello, F
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (10) : 1330 - 1337
  • [10] Reproducibility-Repeatability of Choroidal Thickness Calculation Using Optical Coherence Tomography
    Benavente-Perez, Alexandra
    Hosking, Sarah L.
    Logan, Nicola S.
    Bansal, Dheeraj
    [J]. OPTOMETRY AND VISION SCIENCE, 2010, 87 (11) : 867 - 872