Repeatability and reproducibility of corneal thickness measurements by optical coherence tomography

被引:0
|
作者
Muscat, S [1 ]
McKay, N [1 ]
Parks, S [1 ]
Kemp, E [1 ]
Keating, D [1 ]
机构
[1] Univ Glasgow, Tennent Inst Ophthalmol, Glasgow, Lanark, Scotland
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To assess the repeatability and interoperator and intersession reproducibility of central corneal thickness (CCT) measurements made by a commercially available optical coherence tomography (OCT) system. METHODS. Intersession and interoperator reproducibility and repeatability were defined according to the guidelines of the British Standards Institution and examined in a control group of 14 normal subjects. An in-house computer program was used to evaluate central corneal thickness from these scans. RESULTS. The coefficient of interoperator reproducibility was 0.18%, whereas that for intersession reproducibility was 1.11%. Wilcoxon analysis (5% level of significance) showed that there was no statistically significant difference between scans acquired during different sessions or by different operators. Coefficients of repeatability were all less than 3%. The average CCT was 526 +/- 28 mum (SD) and the range of normal CCT between 5th and 95th percentiles was 498 to 576 mum. CONCLUSIONS. Although the commercially available OCT scanner was designed for retinal imaging, with a few minor modifications, the system may be used to image the anterior segment. Previous studies have shown that OCT measurements correlate well with those from conventional techniques, and it has the added advantage of being a noncontact technique. This study further demonstrates that the OCT measurements show a high degree of repeatability and reproducibility. Thus, OCT is emerging as a promising tool for evaluation of CCT in the clinical setting.
引用
下载
收藏
页码:1791 / 1795
页数:5
相关论文
共 50 条
  • [21] Repeatability and Reproducibility of Corneal Epithelial Thickness Mapping With Spectral-Domain Optical Coherence Tomography in Normal and Diseased Cornea Eyes
    Sella, Ruti
    Zangwill, Linda M.
    Weinreb, Robert N.
    Afshari, Natalie A.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 197 : 88 - 97
  • [22] REPEATABILITY AND REPRODUCIBILITY OF RETINAL THICKNESS MEASUREMENTS WITH SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY USING DIFFERENT SCAN PARAMETERS
    Giani, Andrea
    Peroglio, Antonio
    Staurenghi, Giovanni
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2012, 32 (05): : 1007 - 1012
  • [23] Repeatability and reproducibility of vessel density measurements on optical coherence tomography angiography in diabetic retinopathy
    Levine, Emily S.
    Arya, Malvika
    Chaudhari, Juhi
    Greig, Eugenia Custo
    Alibhai, A. Yasin
    Baumal, Caroline R.
    Witkin, Andre J.
    Duker, Jay S.
    Waheed, Nadia K.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (08) : 1687 - 1695
  • [24] Repeatability and reproducibility of vessel density measurements on optical coherence tomography angiography in diabetic retinopathy
    Emily S. Levine
    Malvika Arya
    Juhi Chaudhari
    Eugenia Custo Greig
    A. Yasin Alibhai
    Caroline R. Baumal
    Andre J. Witkin
    Jay S. Duker
    Nadia K. Waheed
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2020, 258 : 1687 - 1695
  • [25] Intraobserver repeatability and interobserver reproducibility of corneal measurements in normal eyes using an optical coherence tomography-Placido disk device
    Shah, Jinesh M.
    Han, Daphne
    Htoon, Hla Myint
    Mehta, Jodhbir S.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (02): : 372 - 381
  • [26] Repeatability and reproducibility of anterior chamber volume measurements using 3-dimensional corneal and anterior segment optical coherence tomography
    Fukuda, Shinichi
    Kawana, Keisuke
    Yasuno, Yoshiaki
    Oshika, Tetsuro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (03): : 461 - 468
  • [27] Repeatability and Reproducibility of Spectral-domain Optical Coherence Tomography in Measurement of Retinal Thickness in Rats
    Kim, TaeGi
    Yang, Ji Ho
    Han, Jisang
    Yu, Seung-Young
    Kwak, Hyung-Woo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [28] Comparison of the repeatability and reproducibility of corneal thickness mapping using optical coherence tomography according to tear film break-up time
    Lin, Kan
    Xu, Zhiqiang
    Wang, Hui
    Wang, Yuzhou
    Wei, Linzhi
    Ma, Hongqing
    Zhao, Jian
    Lu, Fan
    Hu, Liang
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [29] Reliability and Reproducibility of Assessment of Corneal Epithelial Thickness by Fourier Domain Optical Coherence Tomography
    Prakash, Gaurav
    Agarwal, Amar
    Mazhari, Anjum Iqbal
    Chari, Mathangi
    Kumar, Dhivya Ashok
    Kumar, Gautam
    Singh, Bunty
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (06) : 2580 - 2585
  • [30] Repeatability of Corneal Phase Retardation Measurements by Polarization-Sensitive Optical Coherence Tomography
    Fukuda, Shinichi
    Kishino, Genichiro
    Hoshi, Sujin
    Beheregaray, Simone
    Ueno, Yuta
    Fukuda, Masahiro
    Kasaragod, Deepa
    Yasuno, Yoshiaki
    Oshika, Tetsuro
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (05) : 3196 - 3201