Reliability and Reproducibility of Assessment of Corneal Epithelial Thickness by Fourier Domain Optical Coherence Tomography

被引:53
|
作者
Prakash, Gaurav [1 ]
Agarwal, Amar [1 ]
Mazhari, Anjum Iqbal [1 ]
Chari, Mathangi [1 ]
Kumar, Dhivya Ashok [1 ]
Kumar, Gautam [1 ]
Singh, Bunty [1 ]
机构
[1] Dr Agarwals Eye Hosp & Eye Res Ctr, Madras 600086, Tamil Nadu, India
关键词
TIME-DOMAIN; REPEATABILITY; PACHYMETRY; PROFILE;
D O I
10.1167/iovs.11-8981
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To analyze the intra-user reliability and inter-user reproducibility of assessment of corneal epithelial thickness by Fourier domain optical coherence tomography. METHODS. In this consecutive cross-sectional case series performed at a tertiary ocular care institution, 210 eyes of 210 subjects underwent anterior segment Fourier domain optical coherence tomography (FDOCT). A caliper tool software was used to measure the corneal thickness. For the reproducibility measures, the examination was done by 2 examiners (user 1, user 2) within 30 minutes of each other. For the reliability measure, the retest was done by user 1 on the next day, within 30 minutes of the previous test's time. The total corneal thickness, epithelial thickness, and corneal thickness excluding the epithelium were measured. RESULTS. The mean corneal thickness of the population measured by user 1 was 519.5 +/- 31.1 mu m, 58.6 +/- 4.2 mu m, and 460.95 +/- 31.4 lm for total cornea, epithelium, and non-epithelial cornea, respectively. The difference in results between user 2 and user 1 was 0.8 +/- 7.2 mu m, 0.23 +/- 3.3 lm, and 0.7 +/- 8.2 lm for total, epithelium, and non-epithelial cornea, respectively, and the difference in results between the repeated series by user 1 was 0.49 +/- 5.7 lm, -0.13 +/- 2.7 mu m, 0.61 +/- 5.4 mu m total, epithelium, and non-epithelial cornea, respectively (paired t-test, P > 0.05). Intraclass correlations ranged from 0.87 to 0.99, coefficients of repeatability from 4.5 to 14.11, and coefficient of variation from 2.3% to 11.1%. CONCLUSIONS. Fourier domain anterior segment optical coherence tomography is reproducible and reliable for the measurement of epithelial thickness at vertex. (Invest Ophthalmol Vis Sci. 2012;53:2580-2585) DOI:10.1167/iovs.11-8981
引用
收藏
页码:2580 / 2585
页数:6
相关论文
共 50 条
  • [1] Reproducibility and Daytime-Dependent Changes of Corneal Epithelial Thickness and Whole Corneal Thickness Measured With Fourier Domain Optical Coherence Tomography
    Wasielica-Poslednik, Joanna
    Lisch, Walter
    Bell, Katharina
    Weyer, Veronika
    Pfeiffer, Norbert
    Gericke, Adrian
    [J]. CORNEA, 2016, 35 (03) : 342 - 349
  • [2] Corneal epithelial thickness measured by Fourier-domain optical coherence tomography
    Wang, Ting
    Li, Fengjie
    Wang, Shuting
    Shi, Weiyun
    [J]. SPEKTRUM DER AUGENHEILKUNDE, 2016, 30 (01) : 3 - 9
  • [3] Assessment of corneal epithelial thickness in dry eye patients evaluated by Fourier-domain optical coherence tomography
    Cui, Xinhan
    Hong, Jiaxu
    Wang, Fei
    Yang, Yujing
    Xu, JianJiang
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [4] Assessment of Corneal Epithelial Thickness in Asymmetric Keratoconic Eyes and Normal Eyes Using Fourier Domain Optical Coherence Tomography
    Catalan, S.
    Cadarso, L.
    Esteves, F.
    Salgado-Borges, J.
    Lopez, M.
    Cadarso, C.
    [J]. JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [5] Corneal Epithelial Thickness Mapping by Fourier-Domain Optical Coherence Tomography in Normal and Keratoconic Eyes
    Li, Yan
    Tan, Ou
    Brass, Robert
    Weiss, Jack L.
    Huang, David
    [J]. OPHTHALMOLOGY, 2012, 119 (12) : 2425 - 2433
  • [6] Corneal Epithelial Thickness Mapping in Normal and Keratoconic Eyes With Fourier-Domain Optical Coherence Tomography
    Li, Y.
    Tan, O.
    Huang, D.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [7] Normal and Keratoconic Corneal Epithelial Thickness Mapping using Fourier-Domain Optical Coherence Tomography
    Li, Yan
    Tan, Ou
    Huang, David
    [J]. MEDICAL IMAGING 2011: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2011, 7965
  • [8] Influence of contact lens wearing on whole corneal thickness and corneal epithelial thickness measured with Fourier-domain optical coherence tomography
    Wasielica-Poslednik, Joanna
    Sievers, Marcel Sebastian
    Lisch, Walter
    Weyer, Veronika
    Pfeiffer, Norbert
    Gericke, Adrian
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [9] Repeatability and Reproducibility of Macular Thickness Measurements Using Fourier Domain Optical Coherence Tomography
    Bruce, Alison
    Pacey, Ian E.
    Dharni, Poonam
    Scally, Andy J.
    Barrett, Brendan T.
    [J]. OPEN OPHTHALMOLOGY JOURNAL, 2009, 3 : 10 - 14
  • [10] Comparison of Fourier-Domain and Time-Domain Optical Coherence Tomography for Assessment of Corneal Thickness and Intersession Repeatability
    Prakash, Gaurav
    Agarwal, Amar
    Jacob, Soosan
    Kumar, Dhivya Ashok
    Agarwal, Athiya
    Banerjee, Rumki
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (02) : 282 - 290