Repeatability of corneal and epithelial thickness measurements with anterior segment optical coherence tomography in keratoconus

被引:9
|
作者
Li, Ye [1 ]
Gokul, Akilesh [1 ]
McGhee, Charles [1 ]
Ziaei, Mohammed [1 ]
机构
[1] Univ Auckland, Fac Med & Hlth Sci, New Zealand Natl Eye Ctr, Dept Ophthalmol, Auckland, New Zealand
来源
PLOS ONE | 2021年 / 16卷 / 06期
关键词
REPRODUCIBILITY;
D O I
10.1371/journal.pone.0248350
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To investigate the repeatability in corneal thickness (CT) and epithelial thickness (ET) measurements using spectral domain anterior segment optical coherence tomography (AS-OCT, REVO NX, Optopol) in keratoconus, and examine the effect of corneal crosslinking (CXL) on repeatability. Methods A cross-sectional study of 259 eyes of 212 patients with keratoconus attending the corneal disease clinic at a university hospital tertiary referral center were enrolled. Two groups were analysed: eyes with no prior history of CXL (Group A) and eyes with prior CXL (Group B). Repeatability of measurements was assessed using the intraclass correlation coefficient (ICC) and coefficient of variation (CV). Results In Group A, central corneal thickness (CCT) was 472.18 +/- 45.41 mu m, and the ET was found to be the thinnest in the inferior-temporal aspect at 51.79 +/- 5.97 mu m and thickest at the superior-nasal aspect at 56.07 +/- 5.70 mu m. In Group B, CCT was 465.11 +/- 42.28 mu m, and the ET was the thinnest at the inferior-temporal aspect at 50.63 +/- 5.52 mu m and thickest at the superior aspect at 56.80 +/- 6.39 mu m. When evaluating CT measurements, ICC was above 0.86 and 0.83 for Group A and Group B respectively. When evaluating ET measurements, ICC was above 0.82 for both groups. CXL had no statistically significant impact on the repeatability of measurements. Conclusions AS-OCT provides repeatable CT and ET measurements in the central and peripheral cornea in patients with keratoconus. Repeatability is not affected by a history of CXL.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Repeatability of corneal and epithelial thickness measurements with anterior segment optical coherence tomography in keratoconus
    Li, Ye
    Gokul, Akilesh
    McGhee, Charles
    Ziaei, Mo
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 49 (08): : 884 - 885
  • [2] The repeatability of corneal and corneal epithelial thickness measurements using optical coherence tomography
    Sin, Sokpheaktra
    Simpson, Trefford L.
    [J]. OPTOMETRY AND VISION SCIENCE, 2006, 83 (06) : 360 - 365
  • [3] Anterior segment optical coherence tomography scanning protocols and corneal thickness repeatability
    Fisher, Damien
    Collins, Michael J.
    Vincent, Stephen J.
    [J]. CONTACT LENS & ANTERIOR EYE, 2020, 43 (05): : 433 - 440
  • [4] Repeatability of anterior segment measurements by optical coherence tomography combined with Placido disk corneal topography in eyes with keratoconus
    Schiano-Lomoriello, Domenico
    Bono, Valeria
    Abicca, Irene
    Savini, Giacomo
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [5] Repeatability of anterior segment measurements by optical coherence tomography combined with Placido disk corneal topography in eyes with keratoconus
    Domenico Schiano-Lomoriello
    Valeria Bono
    Irene Abicca
    Giacomo Savini
    [J]. Scientific Reports, 10
  • [6] Anterior Segment Optical Coherence Tomography: Assisted Topographic Corneal Epithelial Thickness Distribution Imaging of a Keratoconus Patient
    Kanellopoulos, A. John
    Asimellis, George
    [J]. CASE REPORTS IN OPHTHALMOLOGY, 2013, 4 (01): : 74 - 78
  • [7] Age-related differences in corneal epithelial thickness measurements with anterior segment optical coherence tomography
    Kim, Bong Jun
    Ryu, Ik-Hee
    Kim, Sun Woong
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2016, 60 (05) : 357 - 364
  • [8] Age-related differences in corneal epithelial thickness measurements with anterior segment optical coherence tomography
    Bong Jun Kim
    Ik-Hee Ryu
    Sun Woong Kim
    [J]. Japanese Journal of Ophthalmology, 2016, 60 : 357 - 364
  • [9] Dissecting the Profile of Corneal Thickness With Keratoconus Progression Based on Anterior Segment Optical Coherence Tomography
    Dong, Yanling
    Li, Dongfang
    Guo, Zhen
    Liu, Yang
    Lin, Ping
    Lv, Bin
    Lv, Chuanfeng
    Xie, Guotong
    Xie, Lixin
    [J]. FRONTIERS IN NEUROSCIENCE, 2022, 15
  • [10] Repeatability and reproducibility of corneal thickness measurements by optical coherence tomography
    Muscat, S
    McKay, N
    Parks, S
    Kemp, E
    Keating, D
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 (06) : 1791 - 1795