μ-dDIHEN: a new micro-flow liquid sample introduction system for direct injection nebulization in ICP-MS

被引:12
|
作者
Louvat, Pascale [1 ]
Tharaud, Mickael [1 ]
Buisson, Matthieu [1 ]
Rollion-Bard, Claire [1 ]
Benedetti, Marc F. [1 ]
机构
[1] Univ Paris, CNRS, Inst Phys Globe Paris, F-75005 Paris, France
关键词
HIGH-EFFICIENCY NEBULIZER; PLASMA-MASS SPECTROMETRY; ORGANIC/HYDRO-ORGANIC MATRICES; OPTICAL-EMISSION SPECTROMETRY; BIOLOGICAL SAMPLES; CHROMATOGRAPHY; ELEMENTS; BORON; PRODUCTS; SEAWATER;
D O I
10.1039/c9ja00146h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The mu-dDIHEN allows direct nebulization of small samples into the plasma at a flow rate down to 5 mu L min(-1). It is composed of a demountable direct injection high efficiency nebulizer (d-DIHEN), a flow injection analysis (FIA) valve and a gas displacement pump (GDP) connected to a mu-mass-flow meter delivering very stable liquid flow. The system was successfully tested with sample loops of 10 and 50 mu L and for liquid flow rates between 5 and 50 mu L min(-1) on two different inductively coupled plasma mass spectrometry (ICP-MS) instruments, a sector-field-ICP-MS (SF-ICP-MS) and a multi-collector-ICP-MS (MC-ICP-MS), and for three different applications: boron isotopic ratio measurement of geological samples, multi-element analyses of natural water samples and gold nanoparticle characterization by single particle ICPMS (spICP-MS). Signal sensitivity was increasing with the liquid uptake rate of the mu-dDIHEN (and the GDP gas flow rate), but stopped increasing above 30 mu L min(-1), due to bad spray quality and poor ionization under extra-wet conditions. We successfully measured boron isotopic ratios (delta B-11) for reference material solutions with B concentrations between 10 and 200 mu g L-1; the reproducibility of the measurements depending on both the B concentration of the sample and the uptake rate: B-10 signals below 20-30 mV (with 10(11) ohms amplifiers) gave 2SD reproducibility >= 0.5 parts per thousand (n = 5). The best measurement conditions were not necessarily with the lowest uptake rate but rather at 25 mu L min(-1), allowing for higher signals. We also tested transient versus continuous measurement modes for a series of natural samples (with 10 and 50 mu L sample loops). The two modes gave fully comparable results but the transient mode allows triplicate delta B-11 measurements and is recommended for very small samples (<= 100 mu L and B content of a few ng). For multi-element analyses by SF-ICP-MS, the limits of quantification (LOQs) of the majority of the trace and ultra-trace elements were lower (up to 15 times) with the mu-dDIHEN than with a concentric nebulizer and spray chamber, due to the much lower sample volume needed. Lastly, the mu-dDIHEN is highly promising for nanoparticle (NP) characterization by spICPMS. The first measurements for gold NPs of 40 nm certified size led to a transport efficiency of 85%.
引用
收藏
页码:1553 / 1563
页数:11
相关论文
共 50 条
  • [41] Direct liquid ablation: a new calibration strategy for laser ablation ICP-MS microanalysis of solids and liquids
    Gunther, D
    Frischknecht, R
    Muschenborn, HJ
    Heinrich, CA
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (4-5): : 390 - 393
  • [42] Application of new covalently-bound diglycolamide sorbent in sequential injection analysis flow system for sample pretreatment in ICP-MS determination of 239Pu at ppt level
    Kolacinska, Kamila
    DeVol, Timothy A.
    Seliman, Ayman F.
    Bliznyuk, Valery N.
    Dudek, Jakub
    Dudek, Marta K.
    Piotrowski, Piotr
    Trojanowicz, Marek
    TALANTA, 2019, 205
  • [43] Determination of trace impurities in high purity copper using sector-field ICP-MS: continuous nebulization, flow injection analysis and laser ablation
    Pattberg, S
    Matschat, R
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (05): : 410 - 416
  • [44] Determination of trace impurities in high purity copper using sector-field ICP-MS: continuous nebulization, flow injection analysis and laser ablation
    S. Pattberg
    R. Matschat
    Fresenius' Journal of Analytical Chemistry, 1999, 364 : 410 - 416
  • [45] Lead isotopic analysis of Antarctic snow by quadrupole ICP-MS using a total-consumption sample introduction system
    Ardini, Francisco
    Bazzano, Andrea
    Grotti, Marco
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (12) : 2124 - 2132
  • [46] Particle Trajectory Simulation Facilitates the Development of an Efficient Sample Introduction System for Single-Particle ICP-MS Analysis
    Wang, Dingyi
    Zhang, Junhui
    Fan, Changjun
    Li, Xiaodong
    Liu, Lihong
    Yan, Xueting
    Li, Yingying
    He, Bin
    Yin, Yongguang
    Hu, Ligang
    Jiang, Guibin
    ANALYTICAL CHEMISTRY, 2025, 97 (03) : 1792 - 1798
  • [47] Elemental recoveries for metal oxide nanoparticles analysed by direct injection ICP-MS: influence of particle size, agglomeration state and sample matrix
    Motellier, Sylvie
    Guiot, Arnaud
    Legros, Samuel
    Fiorentino, Brice
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (12) : 2294 - 2301
  • [48] On-line sample-pre-treatment schemes for trace-level determinations of metals by coupling flow injection or sequential injection with ICP-MS
    Wang, JH
    Hansen, EH
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2003, 22 (11) : 836 - 846
  • [49] Improvements in low-level radionuclide measurement capability through use of the Apex Q sample introduction system combined with ICP-MS/MS
    Russell, Ben
    Falksohn, Frankie
    Tribolet, Alexandre
    Mohamud, Hibaaq
    Pearson, Olivia
    Braysher, Emma
    Burke, Saskia
    Bhaisare, Anu
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (11) : 2929 - 2936
  • [50] Capillary electrophoresis as sample introduction system for highly sensitive and interference-free determination of 99Tc by ICP-MS
    Zhou, Dan
    Bao, Liangjin
    Long, Haoqi
    Zhou, Duo
    Xu, Yuwei
    Wang, Bo
    Xia, Chuanqin
    Xian, Liang
    Zheng, Chengbin
    CHINESE CHEMICAL LETTERS, 2025, 36 (04)