μ-dDIHEN: a new micro-flow liquid sample introduction system for direct injection nebulization in ICP-MS

被引:12
|
作者
Louvat, Pascale [1 ]
Tharaud, Mickael [1 ]
Buisson, Matthieu [1 ]
Rollion-Bard, Claire [1 ]
Benedetti, Marc F. [1 ]
机构
[1] Univ Paris, CNRS, Inst Phys Globe Paris, F-75005 Paris, France
关键词
HIGH-EFFICIENCY NEBULIZER; PLASMA-MASS SPECTROMETRY; ORGANIC/HYDRO-ORGANIC MATRICES; OPTICAL-EMISSION SPECTROMETRY; BIOLOGICAL SAMPLES; CHROMATOGRAPHY; ELEMENTS; BORON; PRODUCTS; SEAWATER;
D O I
10.1039/c9ja00146h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The mu-dDIHEN allows direct nebulization of small samples into the plasma at a flow rate down to 5 mu L min(-1). It is composed of a demountable direct injection high efficiency nebulizer (d-DIHEN), a flow injection analysis (FIA) valve and a gas displacement pump (GDP) connected to a mu-mass-flow meter delivering very stable liquid flow. The system was successfully tested with sample loops of 10 and 50 mu L and for liquid flow rates between 5 and 50 mu L min(-1) on two different inductively coupled plasma mass spectrometry (ICP-MS) instruments, a sector-field-ICP-MS (SF-ICP-MS) and a multi-collector-ICP-MS (MC-ICP-MS), and for three different applications: boron isotopic ratio measurement of geological samples, multi-element analyses of natural water samples and gold nanoparticle characterization by single particle ICPMS (spICP-MS). Signal sensitivity was increasing with the liquid uptake rate of the mu-dDIHEN (and the GDP gas flow rate), but stopped increasing above 30 mu L min(-1), due to bad spray quality and poor ionization under extra-wet conditions. We successfully measured boron isotopic ratios (delta B-11) for reference material solutions with B concentrations between 10 and 200 mu g L-1; the reproducibility of the measurements depending on both the B concentration of the sample and the uptake rate: B-10 signals below 20-30 mV (with 10(11) ohms amplifiers) gave 2SD reproducibility >= 0.5 parts per thousand (n = 5). The best measurement conditions were not necessarily with the lowest uptake rate but rather at 25 mu L min(-1), allowing for higher signals. We also tested transient versus continuous measurement modes for a series of natural samples (with 10 and 50 mu L sample loops). The two modes gave fully comparable results but the transient mode allows triplicate delta B-11 measurements and is recommended for very small samples (<= 100 mu L and B content of a few ng). For multi-element analyses by SF-ICP-MS, the limits of quantification (LOQs) of the majority of the trace and ultra-trace elements were lower (up to 15 times) with the mu-dDIHEN than with a concentric nebulizer and spray chamber, due to the much lower sample volume needed. Lastly, the mu-dDIHEN is highly promising for nanoparticle (NP) characterization by spICPMS. The first measurements for gold NPs of 40 nm certified size led to a transport efficiency of 85%.
引用
收藏
页码:1553 / 1563
页数:11
相关论文
共 50 条
  • [21] Influence of design and operating parameters of pneumatic concentric nebulizer on micro-flow aerosol characteristics and ICP-MS analytical performances
    Geertsen, Valerie
    Lemaitre, Pascal
    Tabarant, Michel
    Chartier, Frederic
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (01) : 146 - 158
  • [22] Direct μ-flow injection isotope dilution ICP-MS for the determination of heavy metals in oil samples
    Jörg Bettmer
    Jens Heilmann
    Daniel J. Kutscher
    Alfredo Sanz-Medel
    Klaus G. Heumann
    Analytical and Bioanalytical Chemistry, 2012, 402 : 269 - 275
  • [23] Direct μ-flow injection isotope dilution ICP-MS for the determination of heavy metals in oil samples
    Bettmer, Joerg
    Heilmann, Jens
    Kutscher, Daniel J.
    Sanz-Medel, Alfredo
    Heumann, Klaus G.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (01) : 269 - 275
  • [24] Determination of trace elements in fuel ethanol by ICP-MS using direct sample introduction by a microconcentric nebulizer
    Tormen, Luciano
    Chaves, Eduardo S.
    Saint'Pierre, Tatiana D.
    Frescura, Vera L. A.
    Curtius, Adilson J.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (09) : 1300 - 1304
  • [25] Development of Aerosol Sample Introduction Interface Coupled with ICP-MS for Direct Introduction and Quantitative Online Monitoring of Environmental Aerosol
    Su, Yong-Yang
    Li, Zhi-Ming
    Li, Mei
    Yi, Xiao-Wei
    Zhou, Guo-Qing
    Xu, Jiang
    Zhai, Li-Hua
    Wei, Guan-Yi
    Zhu, Feng-Rong
    AEROSOL SCIENCE AND TECHNOLOGY, 2014, 48 (01) : 99 - 107
  • [26] On-line removal of mass interferences in palladium determination by ICP-MS using modified capillaries coupled to micro-flow nebulizers
    García, Raquel
    Gómez, Milagros
    Palacios, Ma. Antonia
    Bettmer, Jörg
    Camara, Carmen
    1600, Royal Society of Chemistry (16):
  • [27] On-line removal of mass interferences in palladium determination by ICP-MS using modified capillaries coupled to micro-flow nebulizers
    García, R
    Gómez, M
    Palacios, MA
    Bettmer, J
    Camara, C
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (05) : 481 - 486
  • [28] Validation of the determination of copper and zinc in blood plasma and urine by ICP MS with cross-flow and direct injection nebulization
    Szpunar, J
    Bettmer, J
    Robert, M
    Chassaigne, H
    Cammann, K
    Lobinski, R
    Donard, OFX
    TALANTA, 1997, 44 (08) : 1389 - 1396
  • [29] Isotope dilution ICP-MS with laser-assisted sample introduction for direct determination of sulfur in petroleum products
    Sergei F. Boulyga
    Jens Heilmann
    Klaus G. Heumann
    Analytical and Bioanalytical Chemistry, 2005, 382 : 1808 - 1814
  • [30] Isotope dilution ICP-MS with laser-assisted sample introduction for direct determination of sulfur in petroleum products
    Boulyga, SF
    Heilmann, J
    Heumann, KG
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (08) : 1808 - 1814