Calculation of a pencil beam kernel from measured photon beam data

被引:68
|
作者
Storchi, PRM [1 ]
van Battum, LJ [1 ]
Woudstra, E [1 ]
机构
[1] Univ Rotterdam Hosp, Dr Daniel Den Hoed Canc Ctr, NL-3008 AE Rotterdam, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1999年 / 44卷 / 12期
关键词
D O I
10.1088/0031-9155/44/12/305
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Usually, pencil beam kernels for photon beam calculations are obtained by Monte Carlo calculations. In this paper, we present a method to derive a pencil beam kernel from measured beam data, i.e. central axis depth doses, phantom scatter factors and off-axis ratios. These data are usually available in a radiotherapy planning system. The differences from other similar works are: (a) the central part of the pencil beam is derived from the measured penumbra of large fields and (b) the dependence of the primary photon fluence on the depth caused by beam hardening in the phantom is taken into account. The calculated pencil beam will evidently be influenced by the methods and instruments used for measurement of the basic data set. This is of particular importance for an ac curate prediction of the absorbed dose delivered by small fields. Comparisons with measurements show that the accuracy of the calculated dose distributions fits well in a 2% error interval in the open part of the field, and in a 2 mm isodose shift in the penumbra region.
引用
收藏
页码:2917 / 2928
页数:12
相关论文
共 50 条
  • [31] Experimental characterisation of a proton kernel model for pencil beam scanning techniques
    De Marzi, L.
    Da Fonseca, A.
    Moignier, C.
    Patriarca, A.
    Goudjil, F.
    Mazal, A.
    Buvat, I
    Herault, J.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 : 195 - 203
  • [32] The application of hybrid-pencil beam in electron dose calculation
    Gou, CJ
    Yang, DL
    Zeng, G
    Luo, ZM
    ACTA PHYSICA SINICA, 2002, 51 (11) : 2649 - 2655
  • [33] Developing a Pencil Beam Dose Calculation Algorithm for CyberKnife System
    Liang, B.
    Liu, B.
    Zhou, F.
    Xu, S.
    Wu, Q.
    MEDICAL PHYSICS, 2015, 42 (06) : 3390 - 3390
  • [34] The application of hybrid-pencil beam in electron dose calculation
    Gou, Cheng-Jun
    Yang, Dai-Lun
    Zeng, Ge
    Lou, Zheng-Ming
    Wuli Xuebao/Acta Physica Sinica, 2002, 51 (11): : 2654 - 2655
  • [35] A 3D pencil-beam-based superposition algorithm for photon dose calculation in heterogeneous media
    Tillikainen, L.
    Helminen, H.
    Torsti, T.
    Siljamaki, S.
    Alakuijala, J.
    Pyyry, J.
    Ulmer, W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (14): : 3821 - 3839
  • [36] A plan intercomparison study for the Anisotropic Analytical Algorithm, the collapsed cone and the pencil beam algorithm for photon dose calculation
    Fogliata, A.
    Nicolini, G.
    Vanetti, E.
    Clivio, A.
    Cozzi, L.
    RADIOTHERAPY AND ONCOLOGY, 2006, 78 : S79 - S79
  • [37] THE OPTIMIZATION OF PENCIL BEAM WIDTHS FOR USE IN AN ELECTRON PENCIL BEAM ALGORITHM
    MCPARLAND, BJ
    CUNNINGHAM, JR
    WOO, MK
    MEDICAL PHYSICS, 1988, 15 (04) : 489 - 497
  • [38] Independent planar dose calculation for IMRT segments using a pencil beam extraction technique from measured square field output factors
    Ayyangar, K
    Nehru, R
    Celi, J
    Enke, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1896 - 1896
  • [39] Development of a golden beam data set for the commissioning of a proton double-scattering system in a pencil-beam dose calculation algorithm
    Slopsema, R. L.
    Lin, L.
    Flampouri, S.
    Yeung, D.
    Li, Z.
    McDonough, J. E.
    Palta, J.
    MEDICAL PHYSICS, 2014, 41 (09)
  • [40] A new pencil beam model for photon dose calculations in heterogeneous media
    Zhang, P.
    Simon, A.
    De Crevoisier, R.
    Haigron, P.
    Nassef, M. H.
    Li, B.
    Shu, H.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (07): : 765 - 773