Calculation of a pencil beam kernel from measured photon beam data

被引:68
|
作者
Storchi, PRM [1 ]
van Battum, LJ [1 ]
Woudstra, E [1 ]
机构
[1] Univ Rotterdam Hosp, Dr Daniel Den Hoed Canc Ctr, NL-3008 AE Rotterdam, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1999年 / 44卷 / 12期
关键词
D O I
10.1088/0031-9155/44/12/305
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Usually, pencil beam kernels for photon beam calculations are obtained by Monte Carlo calculations. In this paper, we present a method to derive a pencil beam kernel from measured beam data, i.e. central axis depth doses, phantom scatter factors and off-axis ratios. These data are usually available in a radiotherapy planning system. The differences from other similar works are: (a) the central part of the pencil beam is derived from the measured penumbra of large fields and (b) the dependence of the primary photon fluence on the depth caused by beam hardening in the phantom is taken into account. The calculated pencil beam will evidently be influenced by the methods and instruments used for measurement of the basic data set. This is of particular importance for an ac curate prediction of the absorbed dose delivered by small fields. Comparisons with measurements show that the accuracy of the calculated dose distributions fits well in a 2% error interval in the open part of the field, and in a 2 mm isodose shift in the penumbra region.
引用
收藏
页码:2917 / 2928
页数:12
相关论文
共 50 条
  • [41] THE PENCIL BEAM ANTENNA
    MILLS, BY
    JOURNAL OF GEOPHYSICAL RESEARCH, 1954, 59 (01): : 183 - 183
  • [42] Calculation of Forward Scatter Dose Distribution at the skin entrance from the patient table for fluoroscopically guided interventions using a pencil beam convolution kernel
    Vijayan, Sarath
    Xiong, Zhenyu
    Guo, Chao
    Troville, Jonathan
    Islam, Naveed
    Rudin, Stephen
    Bednarek, Daniel R.
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [43] MEASUREMENTS OF PHOTON PENCIL BEAM USING THERMO-LUMINESCENCE DOSIMETRY
    KUMAR, P
    BLOCH, P
    MEDICAL PHYSICS, 1985, 12 (05) : 672 - 672
  • [44] Comparison of Beam Data for Two Varian ProBeam Pencil Beam Scanning Proton Systems
    Langner, U.
    Langen, K.
    Eley, J.
    Zhu, M.
    Yu, J.
    Chung, H.
    Polf, J.
    Dong, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3499 - 3499
  • [45] Fast Pencil Beam Dose calculation for Proton Therapy Using a Double-Gaussian Beam Model
    da Silva, Joakim
    Ansorge, Richard
    Jena, Rajesh
    FRONTIERS IN ONCOLOGY, 2015, 5
  • [46] CALCULATION OF DOSE DISTRIBUTIONS FOR OBLIQUE-INCIDENCE USING A PENCIL BEAM MODEL OF THE ESSEN NEUTRON BEAM
    MEISSNER, P
    STRAHLENTHERAPIE, 1984, 160 (02) : 116 - 118
  • [47] Photon Dose Calculation Method Based on Monte Carlo Finite-Size Pencil Beam Model in Accurate Radiotherapy
    Zheng, Huaqing
    Sun, Guangyao
    Li, Gui
    Cao, Ruifen
    Pei, Xi
    Hu, Liqin
    Song, Gang
    Wu, Yican
    COMMUNICATIONS IN COMPUTATIONAL PHYSICS, 2013, 14 (05) : 1415 - 1422
  • [48] Technical note: Extraction of proton pencil beam energy spectrum from measured integral depth dose in a cyclotron proton beam system
    Yao, Weiguang
    Farr, Jonathan B.
    MEDICAL PHYSICS, 2021, 48 (11) : 7504 - 7511
  • [49] A model to determine the initial phase space of a clinical electron beam from measured beam data
    Janssen, JJ
    Korevaar, EW
    van Battum, LJ
    Storchi, PRM
    Huizenga, H
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02): : 269 - 286
  • [50] PENCIL BEAM GENERATION FROM A FOCUSED TRANDUCER
    Mota, M. Melo
    van Neer, P. L. M. J.
    Volker, A.
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 32A AND 32B, 2013, 1511 : 924 - 931