Calculation of a pencil beam kernel from measured photon beam data

被引:68
|
作者
Storchi, PRM [1 ]
van Battum, LJ [1 ]
Woudstra, E [1 ]
机构
[1] Univ Rotterdam Hosp, Dr Daniel Den Hoed Canc Ctr, NL-3008 AE Rotterdam, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1999年 / 44卷 / 12期
关键词
D O I
10.1088/0031-9155/44/12/305
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Usually, pencil beam kernels for photon beam calculations are obtained by Monte Carlo calculations. In this paper, we present a method to derive a pencil beam kernel from measured beam data, i.e. central axis depth doses, phantom scatter factors and off-axis ratios. These data are usually available in a radiotherapy planning system. The differences from other similar works are: (a) the central part of the pencil beam is derived from the measured penumbra of large fields and (b) the dependence of the primary photon fluence on the depth caused by beam hardening in the phantom is taken into account. The calculated pencil beam will evidently be influenced by the methods and instruments used for measurement of the basic data set. This is of particular importance for an ac curate prediction of the absorbed dose delivered by small fields. Comparisons with measurements show that the accuracy of the calculated dose distributions fits well in a 2% error interval in the open part of the field, and in a 2 mm isodose shift in the penumbra region.
引用
收藏
页码:2917 / 2928
页数:12
相关论文
共 50 条
  • [21] SEPARATION OF PRIMARY AND SCATTER COMPONENTS OF MEASURED PHOTON-BEAM DATA
    BJARNGARD, BE
    RASHID, H
    OBCEMEA, CH
    PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (12): : 1939 - 1945
  • [22] A pencil beam dose calculation model for CyberKnife system
    Liang, Bin
    Li, Yongbao
    Liu, Bo
    Zhou, Fugen
    Xu, Shouping
    Wu, Qiuwen
    MEDICAL PHYSICS, 2016, 43 (10) : 5380 - 5391
  • [24] Dosimetric verification of a pencil beam algorithm for photon dose calculation in the presence of low-density inhomogeneities
    Malisan, MR
    Del Frate, S
    Foti, C
    PHYSICA MEDICA, 1997, 13 : 122 - 125
  • [25] Refinements of the finite-size pencil beam model of three-dimensional photon dose calculation
    Ostapiak, OZ
    Zhu, Y
    VanDyk, J
    MEDICAL PHYSICS, 1997, 24 (05) : 743 - 750
  • [26] Electron beam dose calculation: Hybrid pencil beam model extended for small fields
    Gou, CJ
    Zeng, G
    Luo, ZM
    ACTA PHYSICA SLOVACA, 2003, 53 (03) : 259 - 265
  • [27] VERIFICATION OF PHOTON DOSE CALCULATION ACCURACY BY THE PENCIL BEAM AND ANALYTICAL ANISOTROPIC ALGORITHM USING MOSFET DETECTORS
    Swinnen, A.
    Nulens, A.
    Verstraete, J.
    Van den Heuvel, F.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S414 - S414
  • [28] Application of activity pencil beam algorithm using measured distribution data of positron emitter nuclei for therapeutic SOBP proton beam
    Miyatake, Aya
    Nishio, Teiji
    MEDICAL PHYSICS, 2013, 40 (09)
  • [29] A pencil-beam photon algorithm for a miniature multileaf collimator
    Dong, L
    Shiu, AS
    Tung, SS
    Hogstrom, KR
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 92 - 95
  • [30] An intercomparison of photon beam data
    Dimofte, A
    Zhu, T
    Finlay, J
    MEDICAL PHYSICS, 2004, 31 (06) : 1862 - 1863