Measurement of protein digestibility in humans by a dual-tracer method

被引:77
|
作者
Devi, Sarita [1 ]
Varkey, Aneesia [1 ]
Sheshshayee, M. S. [3 ]
Preston, Thomas [4 ]
Kurpad, Anura, V [2 ]
机构
[1] St Johns Natl Acad Hlth Sci, St Johns Res Inst, Div Nutr, Bangalore, Karnataka, India
[2] St Johns Natl Acad Hlth Sci, St Johns Res Inst, Dept Physiol, Bangalore, Karnataka, India
[3] Univ Agr Sci, Dept Crop Physiol, Bangalore, Karnataka, India
[4] Scottish Univ Environm Res Ctr, E Kilbride, Lanark, Scotland
来源
AMERICAN JOURNAL OF CLINICAL NUTRITION | 2018年 / 107卷 / 06期
基金
英国惠康基金;
关键词
protein digestibility; legumes; spirulina; stable isotopes; ACID OXIDATION TECHNIQUE; AMINO-ACID; STABLE-ISOTOPE; DEVELOPING-COUNTRIES; NUTRITIONAL QUALITY; SPIRULINA-PLATENSIS; LYSINE REQUIREMENTS; IN-VIVO; INDICATOR; AVAILABILITY;
D O I
10.1093/ajcn/nqy062
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background: Recent evaluations of the risk of dietary protein deficiency have indicated that protein digestibility may be a key limiting factor in the provision of indispensable ammo acids (IAAs), particularly for vulnerable populations living in challenging environments where intestinal dysfunction may exist. Since the digestion of protein occurs only in the small intestine, and the metabolic activity of colonic bacteria confounds measurements at the fecal level, there is a need to develop nonmvasive protein digestibility measurements at the ileal level. Objective: We used a dual-tracer method with stable isotopes to characterize the digestibility of uniformly labeled [C-13]-sprrulina protein as a standard protein, in comparison to a mixture of H-2-labeled crystalline ammo acids, and then demonstrated the use of this standard protein to measure the digestibility of selected legumes (chick pea and mung bean) through the use of proteins that were intrinsically labeled with H-2. Design: The digestibility of uniformly labeled [C-13]-sprrulina was first measured in 6 healthy volunteers (3 males and 3 females) by feeding it along with a standard mixture of H-2-labeled ammo acids, in a dual-tracer, plateau-fed test meal approach. Next, intrinsically labeled legume protein digestibility was studied with a similar dualtracer approach, with uniformly labeled [C-H]-spirulina as the standard, when processed differently before consumption. Results: The average digestibility of IAA in spirulina protein was 85.2%. The average IAA digestibility of intrinsically H-2-labeled chick pea and mung bean protein was 56.6% and 57.7%, respectively. Dehulling of mung bean before ingestion increased the average IAA digestibility by 9.9% in comparison to whole mung bean digestibility. Conclusions: An innovative, minimally invasive "dual-stable lsotope" method was developed to measure protein digestibility, in which the ingestion of an intrinsically H-2-labeled test protein along with a C-13-labeled standard protein of known digestibility allows for an accurate measure of digestion and absorption of the intrinsically labeled protein. This minimally invasive method is critical to redefining protein quality and will aid in revisiting human protein requirements in different settings and in vulnerable populations. This trial was registered at Clinical Trials Registry-India as CTRI/2017/11/010468. Am J Clin Nutr 2018; 107:984-991.
引用
收藏
页码:984 / 991
页数:8
相关论文
共 50 条
  • [21] A CONTINUOUS FAST-RESPONSE DUAL-TRACER ANALYZER FOR HALOGENATED ATMOSPHERIC TRACER STUDIES
    RYDOCK, JP
    LAMB, BK
    JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 1994, 11 (05) : 1262 - 1272
  • [22] Joint Direct Dynamic Analysis in Dual-Tracer PET Imaging
    Zhu, Wentao
    Feng, Tao
    Chen, Mu
    Dong, Yun
    Bao, Jun
    Li, Hongdi
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [23] A dual-tracer method for studying intragastric distribution and gastric emptying of solids and liquids in functional dyspepsia
    Kairemo, KJA
    Koskenpato, J
    Korppi-Tommola, ET
    Farkkila, M
    NUCLEAR MEDICINE COMMUNICATIONS, 1998, 19 (02) : 143 - 147
  • [24] Dual-Tracer Parathyroid Imaging Using Joint SPECT Reconstruction
    Jaruwan Onwanna
    Maythinee Chantadisai
    Tawatchai Chaiwatanarat
    Yothin Rakvongthai
    Nuclear Medicine and Molecular Imaging, 2023, 57 : 126 - 136
  • [25] Dual-tracer background subtraction approach for fluorescent molecular tomography
    Tichauer, Kenneth M.
    Holt, Robert W.
    El-Ghussein, Fadi
    Davis, Scott C.
    Samkoe, Kimberley S.
    Gunn, Jason R.
    Leblond, Frederic
    Pogue, Brian W.
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (01)
  • [26] Retinal vascular permeability determined by dual-tracer fluorescence angiography
    Russ, PK
    Gaylord, GM
    Haselton, FR
    ANNALS OF BIOMEDICAL ENGINEERING, 2001, 29 (08) : 638 - 647
  • [27] Accounting for pharmacokinetic differences in dual-tracer receptor density imaging
    Tichauer, K. M.
    Diop, M.
    Elliott, J. T.
    Samkoe, K. S.
    Hasan, T.
    Lawrence, K. St.
    Pogue, B. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (10): : 2341 - 2351
  • [28] An Evaluation of Simultaneous Dual-Tracer Technique for PET Static Studies
    Figueiras, Francisca P.
    Jimenez, Xavier
    Pareto, Deborah
    Gomez, Vanessa
    Llop, Jordi
    Gispert, Juan D.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3225 - +
  • [29] Initial studies of PET-SPECT dual-tracer imaging
    Shao, Yiping
    Yao, Rutao
    Ma, Tianyu
    Manchiraju, Phani
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4198 - +
  • [30] Dual-TRACER: High resolution fMRI with constrained evolution reconstruction
    Li, Xuesong
    Ma, Xiaodong
    Li, Lyu
    Zhang, Zhe
    Zhang, Xue
    Tong, Yan
    Wang, Lihong
    Song, Sen
    Guo, Hua
    NEUROIMAGE, 2018, 164 : 172 - 182