Measurement of protein digestibility in humans by a dual-tracer method

被引:77
|
作者
Devi, Sarita [1 ]
Varkey, Aneesia [1 ]
Sheshshayee, M. S. [3 ]
Preston, Thomas [4 ]
Kurpad, Anura, V [2 ]
机构
[1] St Johns Natl Acad Hlth Sci, St Johns Res Inst, Div Nutr, Bangalore, Karnataka, India
[2] St Johns Natl Acad Hlth Sci, St Johns Res Inst, Dept Physiol, Bangalore, Karnataka, India
[3] Univ Agr Sci, Dept Crop Physiol, Bangalore, Karnataka, India
[4] Scottish Univ Environm Res Ctr, E Kilbride, Lanark, Scotland
来源
AMERICAN JOURNAL OF CLINICAL NUTRITION | 2018年 / 107卷 / 06期
基金
英国惠康基金;
关键词
protein digestibility; legumes; spirulina; stable isotopes; ACID OXIDATION TECHNIQUE; AMINO-ACID; STABLE-ISOTOPE; DEVELOPING-COUNTRIES; NUTRITIONAL QUALITY; SPIRULINA-PLATENSIS; LYSINE REQUIREMENTS; IN-VIVO; INDICATOR; AVAILABILITY;
D O I
10.1093/ajcn/nqy062
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background: Recent evaluations of the risk of dietary protein deficiency have indicated that protein digestibility may be a key limiting factor in the provision of indispensable ammo acids (IAAs), particularly for vulnerable populations living in challenging environments where intestinal dysfunction may exist. Since the digestion of protein occurs only in the small intestine, and the metabolic activity of colonic bacteria confounds measurements at the fecal level, there is a need to develop nonmvasive protein digestibility measurements at the ileal level. Objective: We used a dual-tracer method with stable isotopes to characterize the digestibility of uniformly labeled [C-13]-sprrulina protein as a standard protein, in comparison to a mixture of H-2-labeled crystalline ammo acids, and then demonstrated the use of this standard protein to measure the digestibility of selected legumes (chick pea and mung bean) through the use of proteins that were intrinsically labeled with H-2. Design: The digestibility of uniformly labeled [C-13]-sprrulina was first measured in 6 healthy volunteers (3 males and 3 females) by feeding it along with a standard mixture of H-2-labeled ammo acids, in a dual-tracer, plateau-fed test meal approach. Next, intrinsically labeled legume protein digestibility was studied with a similar dualtracer approach, with uniformly labeled [C-H]-spirulina as the standard, when processed differently before consumption. Results: The average digestibility of IAA in spirulina protein was 85.2%. The average IAA digestibility of intrinsically H-2-labeled chick pea and mung bean protein was 56.6% and 57.7%, respectively. Dehulling of mung bean before ingestion increased the average IAA digestibility by 9.9% in comparison to whole mung bean digestibility. Conclusions: An innovative, minimally invasive "dual-stable lsotope" method was developed to measure protein digestibility, in which the ingestion of an intrinsically H-2-labeled test protein along with a C-13-labeled standard protein of known digestibility allows for an accurate measure of digestion and absorption of the intrinsically labeled protein. This minimally invasive method is critical to redefining protein quality and will aid in revisiting human protein requirements in different settings and in vulnerable populations. This trial was registered at Clinical Trials Registry-India as CTRI/2017/11/010468. Am J Clin Nutr 2018; 107:984-991.
引用
收藏
页码:984 / 991
页数:8
相关论文
共 50 条
  • [41] Dual-Tracer PET Using Generalized Factor Analysis of Dynamic Sequences
    El Fakhri, Georges
    Trott, Cathryn M.
    Sitek, Arkadiusz
    Bonab, Ali
    Alpert, Nathaniel M.
    MOLECULAR IMAGING AND BIOLOGY, 2013, 15 (06) : 666 - 674
  • [42] A dual-tracer approach to estimate upwelling velocity in coastal Southern California
    Haskell, William Z., II
    Hammond, Douglas E.
    Prokopenko, Maria G.
    EARTH AND PLANETARY SCIENCE LETTERS, 2015, 422 : 138 - 149
  • [43] Cervical spine uptake: Imaging pitfall in dual-tracer parathyroid scintigraphy
    Nguven, Ba
    Ram, Panol
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [44] Uncertainties in gas exchange parameterization during the SAGE dual-tracer experiment
    Smith, Murray J.
    Ho, David T.
    Law, Cliff S.
    McGregor, John
    Popinet, Stephane
    Schlosser, Peter
    DEEP-SEA RESEARCH PART II-TOPICAL STUDIES IN OCEANOGRAPHY, 2011, 58 (06) : 869 - 881
  • [45] Interventional studies for validation of non-invasive dual-tracer PET
    Koeppe, Robert A.
    Fessler, A. Joshi J.
    NEUROIMAGE, 2006, 31 : T60 - T60
  • [46] Dual-tracer PET/CT imaging in evaluation of metastatic hepatocellular carcinoma
    Ho, Chi-Lai
    Chen, Sirong
    Yeung, David W. C.
    Cheng, Thomas K. C.
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (06) : 902 - 909
  • [47] Validity of triple- and dual-tracer techniques to estimate glucose appearance
    Haidar, A.
    Elleri, D.
    Allen, J. M.
    Harris, J.
    Kumareswaran, K.
    Nodale, M.
    Acerini, C. L.
    Wilinska, M. E.
    Jackson, N.
    Umpleby, A. M.
    Evans, M. L.
    Dunger, D. B.
    Hovorka, R.
    AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2012, 302 (12): : E1493 - E1501
  • [48] Separation of dual-tracer PET signals using a deep stacking network
    Qing, Minmin
    Wan, Yiming
    Huang, Wenhua
    Xu, Youqin
    Liu, Huafeng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1013
  • [49] Iodized Contrast A Possible Confusion Factor in Parathyroid Dual-Tracer Scintigraphy
    Loira, Francisco J.
    Alvarez, Ana M.
    Serena, Andres
    Pou, Javier L.
    Nogueiras, Jose M.
    Campos, Luis M.
    CLINICAL NUCLEAR MEDICINE, 2010, 35 (03) : 178 - 180
  • [50] The spatial resolution of dual-tracer fluorescence thermometry in volumetrically illuminated channels
    Myeongsub Kim
    Minami Yoda
    Experiments in Fluids, 2014, 55