Measurement of protein digestibility in humans by a dual-tracer method

被引:77
|
作者
Devi, Sarita [1 ]
Varkey, Aneesia [1 ]
Sheshshayee, M. S. [3 ]
Preston, Thomas [4 ]
Kurpad, Anura, V [2 ]
机构
[1] St Johns Natl Acad Hlth Sci, St Johns Res Inst, Div Nutr, Bangalore, Karnataka, India
[2] St Johns Natl Acad Hlth Sci, St Johns Res Inst, Dept Physiol, Bangalore, Karnataka, India
[3] Univ Agr Sci, Dept Crop Physiol, Bangalore, Karnataka, India
[4] Scottish Univ Environm Res Ctr, E Kilbride, Lanark, Scotland
来源
AMERICAN JOURNAL OF CLINICAL NUTRITION | 2018年 / 107卷 / 06期
基金
英国惠康基金;
关键词
protein digestibility; legumes; spirulina; stable isotopes; ACID OXIDATION TECHNIQUE; AMINO-ACID; STABLE-ISOTOPE; DEVELOPING-COUNTRIES; NUTRITIONAL QUALITY; SPIRULINA-PLATENSIS; LYSINE REQUIREMENTS; IN-VIVO; INDICATOR; AVAILABILITY;
D O I
10.1093/ajcn/nqy062
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background: Recent evaluations of the risk of dietary protein deficiency have indicated that protein digestibility may be a key limiting factor in the provision of indispensable ammo acids (IAAs), particularly for vulnerable populations living in challenging environments where intestinal dysfunction may exist. Since the digestion of protein occurs only in the small intestine, and the metabolic activity of colonic bacteria confounds measurements at the fecal level, there is a need to develop nonmvasive protein digestibility measurements at the ileal level. Objective: We used a dual-tracer method with stable isotopes to characterize the digestibility of uniformly labeled [C-13]-sprrulina protein as a standard protein, in comparison to a mixture of H-2-labeled crystalline ammo acids, and then demonstrated the use of this standard protein to measure the digestibility of selected legumes (chick pea and mung bean) through the use of proteins that were intrinsically labeled with H-2. Design: The digestibility of uniformly labeled [C-13]-sprrulina was first measured in 6 healthy volunteers (3 males and 3 females) by feeding it along with a standard mixture of H-2-labeled ammo acids, in a dual-tracer, plateau-fed test meal approach. Next, intrinsically labeled legume protein digestibility was studied with a similar dualtracer approach, with uniformly labeled [C-H]-spirulina as the standard, when processed differently before consumption. Results: The average digestibility of IAA in spirulina protein was 85.2%. The average IAA digestibility of intrinsically H-2-labeled chick pea and mung bean protein was 56.6% and 57.7%, respectively. Dehulling of mung bean before ingestion increased the average IAA digestibility by 9.9% in comparison to whole mung bean digestibility. Conclusions: An innovative, minimally invasive "dual-stable lsotope" method was developed to measure protein digestibility, in which the ingestion of an intrinsically H-2-labeled test protein along with a C-13-labeled standard protein of known digestibility allows for an accurate measure of digestion and absorption of the intrinsically labeled protein. This minimally invasive method is critical to redefining protein quality and will aid in revisiting human protein requirements in different settings and in vulnerable populations. This trial was registered at Clinical Trials Registry-India as CTRI/2017/11/010468. Am J Clin Nutr 2018; 107:984-991.
引用
收藏
页码:984 / 991
页数:8
相关论文
共 50 条
  • [31] Dual-Tracer H&N Sentinel Node Biopsy
    不详
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (03) : 23N - 23N
  • [32] Dual-Tracer Parathyroid Imaging Using Joint SPECT Reconstruction
    Onwanna, Jaruwan
    Chantadisai, Maythinee
    Chaiwatanarat, Tawatchai
    Rakvongthai, Yothin
    NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 57 (03) : 126 - 136
  • [33] Imaging neuroinflammation in murine endotoxemia: a dual-tracer microPET evaluation
    Turecki, Lauren
    Palandira, Santhoshi P.
    Liu, Hui
    Addorisio, Meghan
    Tsaava, Tea
    Chang, Eric
    Ma, Yilong
    Carrion, Joseph
    Tracey, Kevin J.
    Pavlov, Valentin A.
    JOURNAL OF IMMUNOLOGY, 2020, 204 (01):
  • [34] Dual-tracer imaging of malignant bone involvement using PET
    Moradi F.
    Iagaru A.
    Clinical and Translational Imaging, 2015, 3 (2) : 123 - 131
  • [35] Retinal Vascular Permeability Determined by Dual-Tracer Fluorescence Angiography
    P. K. Russ
    G. M. Gaylord
    F. R. Haselton
    Annals of Biomedical Engineering, 2001, 29 : 638 - 647
  • [36] Key Technologies and Advances of Dual-Tracer Positron Emission Tomography
    Xu Jinmin
    Liu Huafeng
    ACTA OPTICA SINICA, 2022, 42 (17)
  • [37] A NEW METHOD FOR INVITRO MEASUREMENT OF PROTEIN DIGESTIBILITY
    MOZERSKY, SM
    PANETTIERI, RA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1982, 183 (MAR): : 13 - AGFD
  • [38] Sentinel lymph node mapping in breast cancer: Evaluating the dual-tracer method with indocyanine green and radioisotope
    Kwong, A.
    Cheung, B. H. H.
    Man, V. C. M.
    ANNALS OF ONCOLOGY, 2023, 34 : S314 - S314
  • [39] CO2 TRANSFER AT THE AIR-SEA INTERFACE - NUMERICAL TESTS OF THE DUAL-TRACER METHOD
    PHILLIPS, LF
    GEOPHYSICAL RESEARCH LETTERS, 1995, 22 (19) : 2597 - 2600
  • [40] Dual-Tracer PET Image Separation by Deep Learning: A Simulation Study
    Pan, Bolin
    Marsden, Paul K.
    Reader, Andrew J.
    APPLIED SCIENCES-BASEL, 2023, 13 (07):