Measurement of protein digestibility in humans by a dual-tracer method

被引:77
|
作者
Devi, Sarita [1 ]
Varkey, Aneesia [1 ]
Sheshshayee, M. S. [3 ]
Preston, Thomas [4 ]
Kurpad, Anura, V [2 ]
机构
[1] St Johns Natl Acad Hlth Sci, St Johns Res Inst, Div Nutr, Bangalore, Karnataka, India
[2] St Johns Natl Acad Hlth Sci, St Johns Res Inst, Dept Physiol, Bangalore, Karnataka, India
[3] Univ Agr Sci, Dept Crop Physiol, Bangalore, Karnataka, India
[4] Scottish Univ Environm Res Ctr, E Kilbride, Lanark, Scotland
来源
AMERICAN JOURNAL OF CLINICAL NUTRITION | 2018年 / 107卷 / 06期
基金
英国惠康基金;
关键词
protein digestibility; legumes; spirulina; stable isotopes; ACID OXIDATION TECHNIQUE; AMINO-ACID; STABLE-ISOTOPE; DEVELOPING-COUNTRIES; NUTRITIONAL QUALITY; SPIRULINA-PLATENSIS; LYSINE REQUIREMENTS; IN-VIVO; INDICATOR; AVAILABILITY;
D O I
10.1093/ajcn/nqy062
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background: Recent evaluations of the risk of dietary protein deficiency have indicated that protein digestibility may be a key limiting factor in the provision of indispensable ammo acids (IAAs), particularly for vulnerable populations living in challenging environments where intestinal dysfunction may exist. Since the digestion of protein occurs only in the small intestine, and the metabolic activity of colonic bacteria confounds measurements at the fecal level, there is a need to develop nonmvasive protein digestibility measurements at the ileal level. Objective: We used a dual-tracer method with stable isotopes to characterize the digestibility of uniformly labeled [C-13]-sprrulina protein as a standard protein, in comparison to a mixture of H-2-labeled crystalline ammo acids, and then demonstrated the use of this standard protein to measure the digestibility of selected legumes (chick pea and mung bean) through the use of proteins that were intrinsically labeled with H-2. Design: The digestibility of uniformly labeled [C-13]-sprrulina was first measured in 6 healthy volunteers (3 males and 3 females) by feeding it along with a standard mixture of H-2-labeled ammo acids, in a dual-tracer, plateau-fed test meal approach. Next, intrinsically labeled legume protein digestibility was studied with a similar dualtracer approach, with uniformly labeled [C-H]-spirulina as the standard, when processed differently before consumption. Results: The average digestibility of IAA in spirulina protein was 85.2%. The average IAA digestibility of intrinsically H-2-labeled chick pea and mung bean protein was 56.6% and 57.7%, respectively. Dehulling of mung bean before ingestion increased the average IAA digestibility by 9.9% in comparison to whole mung bean digestibility. Conclusions: An innovative, minimally invasive "dual-stable lsotope" method was developed to measure protein digestibility, in which the ingestion of an intrinsically H-2-labeled test protein along with a C-13-labeled standard protein of known digestibility allows for an accurate measure of digestion and absorption of the intrinsically labeled protein. This minimally invasive method is critical to redefining protein quality and will aid in revisiting human protein requirements in different settings and in vulnerable populations. This trial was registered at Clinical Trials Registry-India as CTRI/2017/11/010468. Am J Clin Nutr 2018; 107:984-991.
引用
收藏
页码:984 / 991
页数:8
相关论文
共 50 条
  • [1] Editorial on "Measurement of protein digestibility in humans by a dual tracer method"-a key limiting factor of protein quality
    Tome, Daniel
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2018, 107 (06): : 855 - 856
  • [2] MEASUREMENT OF DISTRIBUTION COEFFICIENTS USING A RADIAL INJECTION DUAL-TRACER TEST
    PICKENS, JF
    JACKSON, RE
    INCH, KJ
    MERRITT, WF
    WATER RESOURCES RESEARCH, 1981, 17 (03) : 529 - 544
  • [3] Dynamic Dual-Tracer PET Reconstruction
    Gao, Fei
    Liu, Huafeng
    Jian, Yiqiang
    Shi, Pengcheng
    INFORMATION PROCESSING IN MEDICAL IMAGING, PROCEEDINGS, 2009, 5636 : 38 - +
  • [4] Short communication: Estimation of ileal digestibility in chickens using single- and dual-tracer methods
    de Vries, S.
    Laar, H. Beukers-van
    Ruiz, A. I. Garcia
    Gerrits, W. J. J.
    ANIMAL, 2023, 17 (11)
  • [5] Temporally overlapping dual-tracer PET studies
    Koeppe, RA
    Ficaro, EP
    Raffel, DM
    Minoshima, S
    Kilbourn, MR
    QUANTITATIVE FUNCTIONAL BRAIN IMAGING WITH POSITRON EMISSION TOMOGRAPHY, 1998, : 359 - 366
  • [6] Dual-tracer PET/CT in hepatocellular carcinoma
    Baker, Holly
    LANCET GASTROENTEROLOGY & HEPATOLOGY, 2018, 3 (05): : 301 - 301
  • [7] Pinto Bean Amino Acid Digestibility and Score in a Mexican Dish with Corn Tortilla and Guacamole, Evaluated in Adults Using a Dual-Tracer Isotopic Method
    Calderon de la Barca, Ana M.
    Martinez-Diaz, Gerardo
    Ibarra-Pastrana, Erika N.
    Devi, Sarita
    Kurpad, Anura, V
    Valencia, Mauro E.
    JOURNAL OF NUTRITION, 2021, 151 (10): : 3151 - 3157
  • [8] Dual-tracer PET/CT in the management of hepatocellular carcinoma
    Chiu, Keith Wan Hang
    Chiang, Chi Leung
    Chan, Kenneth Sik Kwan
    Hui, Yuan
    Ren, Jingyun
    Wei, Xiaojuan
    Ng, Kwok Sing
    Lee, Ho Fun Victor
    Chia, Nam Hung
    Cheung, Tan-To
    Chan, Stephen
    Chan, Albert Chi-Yan
    Ng, Kwok Chai Kelvin
    Seto, Wai Kay Walter
    Khong, Pek-Lan
    Kong , Feng-Ming
    JHEP REPORTS, 2024, 6 (07)
  • [9] Design of a generic method for single dual-tracer PET imaging acquisition in clinical routine
    Taheri, Nasrin
    Le Crom, Benjamin
    Bouillot, Caroline
    Cherel, Michel
    Costes, Nicolas
    Gouard, Sebastien
    Marionneau-Lambot, Severine
    Merlin, Thibault
    Visvikis, Dimitris
    Stute, Simon
    Carlier, Thomas
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (08):
  • [10] Improving Efficiency of Simultaneous Dual-Tracer PET Imaging
    Li, Z.
    Shah, V.
    Viol, S. L. M.
    Van Snick, P.
    Luurtsema, G.
    Slart, R. H. J. A.
    Lammertsma, A.
    Tsoumpas, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S705 - S705