Method for correction of rotation errors in Micro-CT System

被引:11
|
作者
Zhao, Jintao [1 ]
Hu, Xiaodong [1 ,2 ]
Zou, Jing [1 ,2 ]
Zhao, Gengyan [1 ]
Lv, Hanyu [1 ]
Xu, Linyan [1 ]
Xu, Ying [1 ]
Hu, Xiaotang [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China
[2] BCMIIS, Beijing 100089, Peoples R China
基金
中国国家自然科学基金;
关键词
Micro-CT; Rotation errors; Precision machined cylinder; Resolution; Capacitive sensor; CONE-BEAM CT; COMPUTED-TOMOGRAPHY; CALIBRATION; RESOLUTION; MISALIGNMENT;
D O I
10.1016/j.nima.2016.01.051
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In Micro-CT (Computed Tomography) system, a series of projection data of sample are collected by the detector as the precision stage rotates step by step. However, the accuracy of projection images is limited by rotation errors during the acquisition process. Therefore, evaluating the performance of precision rotary stage and developing corresponding compensation method are necessary in Micro-CT system. In this paper, a metered system is designed which is composed of four precision capacitive sensors, a precision machined steel cylinder and four flexible hinges. Based on the metered system, a method to calibrate and correct the errors when the precision stage turns is proposed. Firstly, the theoretical analysis is proposed and the imperfect situations are considered. And then, the method has been applied to correct experimental data taken from a microscope type of Micro-CT system. Successful results are shown through evaluating MTF (Modulation Transfer Function) of Micro-CT system. Lastly, a sample of tungsten wire is scanned and the reconstructed images are compared before and after using the calibrated method. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:149 / 159
页数:11
相关论文
共 50 条
  • [41] Correction to: Quantitative topographic anatomy of the femoral ACL footprint: a micro-CT analysis
    Danielle G. Norman
    Alan Getgood
    John Thornby
    Jonathan Bird
    Glen A. Turley
    Tim Spalding
    Mark A. Williams
    Medical & Biological Engineering & Computing, 2018, 56 : 339 - 339
  • [42] Micro-CT as a guide for clinical CT development
    Ritman, Erik L.
    Eaker, Diane R.
    Jorgensen, Steven M.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [43] Laboratory 3D Micro-XRF/Micro-CT Imaging System
    Bruyndonckx, P.
    Sasov, A.
    Liu, X.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 61 - 64
  • [44] Implementation of interior micro-CT on a carbon nanotube dynamic micro-CT scanner for lower radiation dose
    Gong, Hao
    Lu, Jianping
    Zhou, Otto
    Cao, Guohua
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [45] Efficient digitalization method for dental restorations using micro-CT data
    Changhwan Kim
    Seung Hoon Baek
    Taewon Lee
    Jonggun Go
    Sun Young Kim
    Seungryong Cho
    Scientific Reports, 7
  • [46] E15.5 Mouse Embryo Micro-CT Using a Bruker Skyscan 1172 Micro-CT
    Astanina, Elena
    Petrillo, Sara
    Genova, Tullio
    Mussano, Federico
    Bussolino, Federico
    BIO-PROTOCOL, 2023, 13 (09):
  • [47] A new method to identify void constrictions in micro-CT images of sand
    Taylor, H. F.
    O'Sullivan, C.
    Sim, W. W.
    COMPUTERS AND GEOTECHNICS, 2015, 69 : 279 - 290
  • [48] Improved method of in vivo respiratory-gated micro-CT imaging
    Walters, EB
    Panda, K
    Bankson, JA
    Brown, E
    Cody, DD
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (17): : 4163 - 4172
  • [49] Efficient digitalization method for dental restorations using micro-CT data
    Kim, Changhwan
    Baek, Seung Hoon
    Lee, Taewon
    Go, Jonggun
    Kim, Sun Young
    Cho, Seungryong
    SCIENTIFIC REPORTS, 2017, 7
  • [50] A novel method to explore intrarenal arterial tree using micro-CT
    Heryan, Katarzyna
    Skrzat, Janusz
    Tarasiuk, Jacek
    Wronski, Sebastian
    2018 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST), 2018, : 260 - 265