Method for correction of rotation errors in Micro-CT System

被引:11
|
作者
Zhao, Jintao [1 ]
Hu, Xiaodong [1 ,2 ]
Zou, Jing [1 ,2 ]
Zhao, Gengyan [1 ]
Lv, Hanyu [1 ]
Xu, Linyan [1 ]
Xu, Ying [1 ]
Hu, Xiaotang [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China
[2] BCMIIS, Beijing 100089, Peoples R China
基金
中国国家自然科学基金;
关键词
Micro-CT; Rotation errors; Precision machined cylinder; Resolution; Capacitive sensor; CONE-BEAM CT; COMPUTED-TOMOGRAPHY; CALIBRATION; RESOLUTION; MISALIGNMENT;
D O I
10.1016/j.nima.2016.01.051
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In Micro-CT (Computed Tomography) system, a series of projection data of sample are collected by the detector as the precision stage rotates step by step. However, the accuracy of projection images is limited by rotation errors during the acquisition process. Therefore, evaluating the performance of precision rotary stage and developing corresponding compensation method are necessary in Micro-CT system. In this paper, a metered system is designed which is composed of four precision capacitive sensors, a precision machined steel cylinder and four flexible hinges. Based on the metered system, a method to calibrate and correct the errors when the precision stage turns is proposed. Firstly, the theoretical analysis is proposed and the imperfect situations are considered. And then, the method has been applied to correct experimental data taken from a microscope type of Micro-CT system. Successful results are shown through evaluating MTF (Modulation Transfer Function) of Micro-CT system. Lastly, a sample of tungsten wire is scanned and the reconstructed images are compared before and after using the calibrated method. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:149 / 159
页数:11
相关论文
共 50 条
  • [21] Adaptive region of interest method for analytical micro-CT reconstruction
    Yang, Wanneng
    Xu, Xiaochun
    Bi, Kun
    Zeng, Shaoqun
    Liu, Qian
    Chen, Shangbin
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2011, 19 (01) : 23 - 33
  • [22] Verification of a method to detect glass microspheres via micro-CT
    Crookston, Nathan R.
    Pasciak, Alexander S.
    Abiola, Godwin
    Donahue, Danielle
    Weiss, Clifford R.
    Frey, Eric C.
    MEDICAL PHYSICS, 2019, 46 (12) : 5623 - 5636
  • [23] Ethanol fixation method for heart and lung imaging in micro-CT
    Matej Patzelt
    Jana Mrzilkova
    Jan Dudak
    Frantisek Krejci
    Jan Zemlicka
    Jakub Karch
    Vladimir Musil
    Jozef Rosina
    Viktor Sykora
    Barbora Horehledova
    Petr Zach
    Japanese Journal of Radiology, 2019, 37 : 500 - 510
  • [24] Analysis of atherosclerosis with micro-CT
    Mohr, A
    Roemer, F
    Genant, H
    RADIOLOGY, 2005, 235 (01) : 338 - 339
  • [25] Application of Micro-CT: A New Method for Stone Drilling Research
    Yang, Yimin
    Yang, Min
    Xie, Yaoting
    Wang, Changsui
    MICROSCOPY RESEARCH AND TECHNIQUE, 2009, 72 (04) : 343 - 346
  • [26] Micro-CT in drug delivery
    Wang, Yiwei
    Wertheim, David F.
    Jones, Allan S.
    Coombes, Allan G. A.
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2010, 74 (01) : 41 - 49
  • [27] High-Resolution Spectral Micro-CT: System Design, Reconstruction Method and Preliminary Results
    Wang, Q.
    Zhu, Y.
    Deng, S.
    Zhang, H.
    Yu, H.
    MEDICAL PHYSICS, 2019, 46 (06) : E210 - E211
  • [28] Micro-CT performance testing
    Eloot, L.
    Buls, N.
    Willekens, I.
    Lahoutte, T.
    de Mey, J.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 154 - 157
  • [29] Spectral optimization for micro-CT
    Hupfer, Martin
    Nowak, Tristan
    Brauweiler, Robert
    Eisa, Fabian
    Kalender, Willi A.
    MEDICAL PHYSICS, 2012, 39 (06) : 3229 - 3239
  • [30] State of art micro-CT
    Sassov, A