A novel method to explore intrarenal arterial tree using micro-CT

被引:0
|
作者
Heryan, Katarzyna [1 ]
Skrzat, Janusz [2 ]
Tarasiuk, Jacek [3 ]
Wronski, Sebastian [3 ]
机构
[1] AGH Univ Sci & Technol, Dept Measurement & Elect, Krakow, Poland
[2] Jagiellonian Univ, Dept Anat, Coll Med, Krakow, Poland
[3] AGH Univ Sci & Technol, Dept Condensed Matter Phys, Krakow, Poland
关键词
micro-CT; 3D vascular tree; kidney; injection materials; cast; contrast agents; ability to absorb ionizing radiation; kidney surgery; minimally invasive surgery; PARTIAL NEPHRECTOMY; ISCHEMIA; TUMOR;
D O I
暂无
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
The minimally invasive approach for renal surgeries, among others, requires preoperative determination of intrarenal arteries. Their proper identification based on standard preoperative CT images is still not a fully solved problem. Therefore, we decided to resolve this issue by providing a tree topology model using post-mortem kidneys. The number of vessels that compose intrarenal tree is so large, that it cannot by analyzed manually without the aid of image processing techniques. So that, the vessels has to be first depicted using an imaging technique that enables to provide superior resolution in comparison to standard CT scan. In this paper, we present a research on various injection materials enabling to fill the vascular beds in order to scan them using micro-CT and further reconstruct as a 3D model. The evaluated materials were chosen so that they are widely available and affordable. We compare them in terms of their ability to absorb ionizing radiation and penetrate vascular beds (density, viscosity), homogeneity, solidification rate, resistance to solvents and durability. We also present the technique of injecting kidney arteries with the use of the selected material - two-part epoxy adhesive with 10% iodine. In contrast to standard corrosive endocast preparation, in our case there is no need to remove soft parenchymal tissue which takes about two weeks using corrosive materials such as strong acids and bases. The proposed filling material enables to enhance vascular tree to such extend that micro-CT scans of the whole kidneys can be performed. This enables instantaneous substance injection and imaging without permanently destroying the soft tissue material. This approach can be used in various scenarios in which a filling material with the ability to increase radiation absorption is required and there is a need to maintain the integrity of the structure. To the best of our knowledge, this is the first such attempt. The obtained vascular trees by the means of micro-CT confirm the validity of the presented approach.
引用
收藏
页码:260 / 265
页数:6
相关论文
共 50 条
  • [1] Quantitative arterial tree morphometry using 3D Micro-CT
    Johnson, RH
    Molthen, RC
    Hanger, CC
    Haworth, ST
    Dawson, CA
    Linehan, JH
    [J]. RADIOLOGY, 1998, 209P : 400 - 400
  • [2] Semi-automated skeletonization of the pulmonary arterial tree in micro-CT images
    Hanger, CC
    Haworth, ST
    Molthen, RA
    Dawson, CA
    [J]. MEDICAL IMAGING 2001: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 2001, 4321 : 510 - 516
  • [3] Performance evaluation of the General Electric eXplore CT 120 micro-CT using the vmCT phantom
    Bahri, M. A.
    Warnock, G.
    Plenevaux, A.
    Choquet, P.
    Constantinesco, A.
    Salmon, E.
    Luxen, A.
    Seret, A.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S181 - S185
  • [4] Novel Micro-CT Method To Assess Atherosclerotic Calcification In Mice
    Kaur, Jashandeep
    Carpo, Beatrice
    Kosciuszek, Nina D.
    Singh, Mohnish
    Savinova, Olga V.
    [J]. ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2021, 41
  • [5] Assessment of bone quality using micro-computed tomography (micro-CT) and synchrotron micro-CT
    Ito, M
    [J]. JOURNAL OF BONE AND MINERAL METABOLISM, 2005, 23 (Suppl 1) : 115 - 121
  • [6] Assessment of bone quality using micro-computed tomography (micro-CT) and synchrotron micro-CT
    Masako Ito
    [J]. Journal of Bone and Mineral Metabolism, 2005, 23 : 115 - 121
  • [7] Performance Evaluation of the GE eXplore CT 120 Micro-CT for Various Scanning Protocols
    Bahri, Mohamed A.
    Bretin, Florian
    Warnock, Geoffrey I.
    Luxen, Andre
    Salmon, Eric
    Plenevaux, Alain
    Seret, Alain
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3783 - 3785
  • [8] Classification of Microcalcifications using Micro-CT
    Temmermans, Frederik
    Jansen, Bart
    Willekens, Inneke
    Van de Casteele, Elke
    Deklerck, Rudi
    Schelkens, Peter
    De Mey, Johan
    [J]. APPLICATIONS OF DIGITAL IMAGE PROCESSING XXXVI, 2013, 8856
  • [9] Efficient digitalization method for dental restorations using micro-CT data
    Changhwan Kim
    Seung Hoon Baek
    Taewon Lee
    Jonggun Go
    Sun Young Kim
    Seungryong Cho
    [J]. Scientific Reports, 7
  • [10] Ultrasonic cartilage thickness measurement is accurate, reproducible and reliable - validation using a novel micro-CT method
    Steppacher, Simon Damian
    Hanke, Markus Simon
    Zurmuehle, Corinne
    Haefeli, Pascal Cyrill
    Klenke, Frank Michael
    Tannast, Moritz
    [J]. SWISS MEDICAL WEEKLY, 2017, 147 : 35S - 36S