Glaucoma Diagnostic Accuracy of Optical Coherence Tomography Parameters in Early Glaucoma with Different Types of Optic Disc Damage

被引:28
|
作者
Shin, Hye-Young [1 ]
Park, Hae-Young Lopilly [2 ]
Jung, Younhea [2 ]
Choi, Jin-A [3 ]
Park, Chan Kee [2 ]
机构
[1] Catholic Univ, Coll Med, Uijeongbu St Marys Hosp, Dept Ophthalmol, Seoul 137701, South Korea
[2] Catholic Univ, Coll Med, Seoul St Marys Hosp, Dept Ophthalmol & Visual Sci, Seoul 137701, South Korea
[3] Catholic Univ, Coll Med, St Vincent Hosp, Dept Ophthalmol, Seoul 137701, South Korea
关键词
VISUAL-FIELD; PROGRESSION; APPEARANCES; PATTERNS; RATES; LAYER;
D O I
10.1016/j.ophtha.2014.04.030
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the initial visual field (VF) defect pattern and the spectral-domain optical coherence tomography (OCT) parameters and investigate the effects of distinct types of optic disc damage on the diagnostic performance of these OCT parameters in early glaucoma. Design: Retrospective, observational study. Participants: A total of 138 control eyes and 160 eyes with early glaucoma were enrolled. The glaucomatous eyes were subdivided into 4 groups according to the type of optic disc damage: focal ischemic (FI) group, myopic (MY) group, senile sclerotic (SS) group, and generalized enlargement (GE) group. Methods: The values of total deviation (TD) maps were analyzed, and superior-inferior (S-I) differences of TD were calculated. The optic nerve head (ONH) parameters, peripapillary retinal nerve fiber layer (pRNFL), and ganglion cell-inner plexiform layer (GCIPL) thicknesses were measured. Main Outcome Measures: Comparison of diagnostic ability using area under the receiver operating characteristic curves (AUCs). Results: The S-I and central S-I difference of the FI group were larger than those of the GE group. The rim area of the SS group was larger than those of the 3 other groups, and the vertical cup-to-disc ratio (CDR) of the GE group was larger than that of the MY group. In addition, the minimum and inferotemporal GCIPL thicknesses of the FI group were smaller than those of the GE group. The AUC of the rim area (0.89) was lower than that of the minimum GCIPL (0.99) in the SS group, and the AUC of the vertical CDR (0.90) was lower than that of the minimum GCIPL (0.99) in the MY group. Furthermore, the AUCs of the minimum GCIPL thicknesses of the FI and MY group were greater than those of the average pRNFL thickness for detecting glaucoma, as opposed to the SS and GE. Conclusions: The OCT parameters differed among the 4 groups on the basis of the distinct optic disc appearance and initial glaucomatous damage pattern. Clinicians should be aware that the diagnostic capability of OCT parameters could differ according to the type of optic disc damage in early glaucoma. (C) 2014 by the American Academy of Ophthalmology.
引用
收藏
页码:1990 / 1997
页数:8
相关论文
共 50 条
  • [41] Diagnostic ability of a linear discriminant function for optic nerve head parameters measured with optical coherence tomography for perimetric glaucoma
    Pablo, L. E.
    Ferreras, A.
    Pajarin, A. B.
    Fogagnolo, P.
    EYE, 2010, 24 (06) : 1051 - 1057
  • [42] Detection of early glaucoma with optical coherence tomography (StratusOCT)
    Nouri-Mahdavi, Kouros
    Nikkhou, Kiavash
    Hoffman, Douglas C.
    Law, Simon K.
    Caprioli, Joseph
    JOURNAL OF GLAUCOMA, 2008, 17 (03) : 183 - 188
  • [43] Diagnostic evaluation of optical coherence tomography parameters in normal, preperimetric and perimetric glaucoma patients
    Yusof, Aimy Mastura Zurairah
    Othman, Othmaliza
    Tang, Seng Fai
    Hassan, Mohd Rohaizat
    Din, Norshamsiah Md
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2022, 15 (11) : 1782 - 1790
  • [44] Diagnostic evaluation of optical coherence tomography parameters in normal, preperimetric and perimetric glaucoma patients
    Aimy Mastura Zurairah Yusof
    Othmaliza Othman
    Seng Fai Tang
    Mohd Rohaizat Hassan
    Norshamsiah Md Din
    International Journal of Ophthalmology, 2022, 15 (11) : 1782 - 1790
  • [45] Accuracy of optical coherence tomography (OCT) pachymetry in glaucoma patients
    Strandas, Robert
    Ayala, Marcelo
    ACTA OPHTHALMOLOGICA, 2014, 92 : 3 - 3
  • [46] Accuracy of optical coherence tomography (OCT) in pachymetry for glaucoma patients
    Marcelo Ayala
    Robert Strandås
    BMC Ophthalmology, 15
  • [47] Accuracy of optical coherence tomography (OCT) in pachymetry for glaucoma patients
    Ayala, Marcelo
    Strandas, Robert
    BMC OPHTHALMOLOGY, 2015, 15
  • [48] Response: Optical Coherence Tomography Angiography of Optic Disc and Macula Vessel Density in Glaucoma and Healthy Eyes
    Yip, Vivien C. H.
    Wong, Hon Tym
    Yong, Vernon K. Y.
    Lim, Boon-Ang
    Hee, Owen K.
    Cheng, Jun
    Fu, Huazhu
    Lim, Ching-Wei
    Tay, Elton L. T.
    Loo-Valdez, Roselyn G.
    Teo, Hwei-Yee
    Lim, Angela P. H.
    Yip, Leonard W. L.
    JOURNAL OF GLAUCOMA, 2019, 28 (07) : E132 - E133
  • [49] Optic Disc Margin Anatomy in Patients with Glaucoma and Normal Controls with Spectral Domain Optical Coherence Tomography
    Reis, Alexandre S. C.
    Sharpe, Glen P.
    Yang, Hongli
    Nicolela, Marcelo T.
    Burgoyne, Claude F.
    Chauhan, Balwantray C.
    OPHTHALMOLOGY, 2012, 119 (04) : 738 - 747
  • [50] Evaluation of Optic Disc Perfusion in Normal-Tension Glaucoma Patients by Optical Coherence Tomography Angiography
    Zhu, Dagny
    Reznik, Alena
    Chen, Chieh-Li
    Wang, Ruikang K.
    Puliafito, Carmen A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)