Accuracy of optical coherence tomography (OCT) in pachymetry for glaucoma patients

被引:9
|
作者
Ayala, Marcelo [1 ,2 ,3 ]
Strandas, Robert [1 ]
机构
[1] Skaraborgs Hosp, Eye Dept, Skovde, Sweden
[2] Gothenburg Univ, Sahlgrenska Acad, S-54185 Skovde, Sweden
[3] Karolinska Inst, S-54185 Skovde, Sweden
来源
BMC OPHTHALMOLOGY | 2015年 / 15卷
关键词
Accuracy; Optical coherence tomography; Ultrasound pachymetry; Pachymetry; CENTRAL CORNEAL THICKNESS; OPEN-ANGLE GLAUCOMA; ULTRASOUND PACHYMETRY; INTRAOCULAR-PRESSURE; KERATOCONUS;
D O I
10.1186/s12886-015-0116-x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Central corneal thickness (CCT) measurement has become an important test in the diagnosis and management of glaucoma. Currently, ultrasound corneal thickness measurement (pachymetry) is the most frequently used clinical technique and the gold standard to assess CCT. Newer instruments are currently available including the optical coherence tomography (OCT) instrument. The aim of the present study was therefore to evaluate the accuracy of the CCT measurements performed by three different observers, both with the OCT and ultrasound pachymetry (USP), in patients suffering from glaucoma. Methods: Patients who had been previously diagnosed with glaucoma participated in this cross-sectional study. Glaucoma was defined as patients who had at least two repeatable Humphrey visual fields showing glaucoma damage using the software 24-2, and with the optic nerve showing typical glaucoma damage. The patients CCTs were measured with OCT and USP by three different examiners. Results: Seventy eyes of 35 patients were included. The average age was 74 +/- standard deviation (SD) 10.88, the average pachymetry value with OCT was 536 +/- 29 mu m, and the average pachymetry with USP was 532 +/- 32 mu m. The differences between OCT and USP were not significant (t-test, p = 0.32). The intraclass correlation coefficients were, for OCT, 0.99 [confidence interval (CI): 0.98-0.996], and for USP, 0.97 (CI: 0.95-0.98). Conclusions: Agreement among the three observers using OCT or USP for pachymetry measurements was good. OCT might be used as an alternative method for pachymetry in glaucoma patients.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Accuracy of optical coherence tomography (OCT) in pachymetry for glaucoma patients
    Marcelo Ayala
    Robert Strandås
    [J]. BMC Ophthalmology, 15
  • [2] Accuracy of optical coherence tomography (OCT) pachymetry in glaucoma patients
    Strandas, Robert
    Ayala, Marcelo
    [J]. ACTA OPHTHALMOLOGICA, 2014, 92 : 3 - 3
  • [3] Accuracy of Optical Coherence Tomography versus Ultrasound in pachymetry
    Vonor, K.
    Amedome, K. M.
    Santos, M. A. K.
    Koko, R. A. Kuaovi
    Maneh, N.
    Dzidzinyo, K.
    Ayena, K. D.
    Banla, M.
    Balo, K. P.
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 2021, 44 (07): : 1047 - 1051
  • [4] Optical Coherence Tomography (OCT) in Glaucoma Diagnostics
    Hoffmann, E. M.
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2012, 229 (02) : 135 - 142
  • [5] Diagnostic accuracy of optical coherence tomography angiography (OCTA) versus spectral domain optical coherence tomography (SD-OCT) parameters in perimetric glaucoma
    McCann, Paul M.
    Hogg, Ruth E.
    Young, Ian
    Kee, Frank
    Azuara-Blanco, Augusto
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [6] Comparison of optical coherence tomography (OCT) and histology at the neural rim in glaucoma
    Dawson, WW
    Moores, MD
    Reitze, DH
    Brooks, DE
    Sergeev, A
    Gelatt, KN
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 5259 - 5259
  • [7] Optical coherence tomography (OCT)
    Liebmann, J
    Bowd, C
    Medeiros, FA
    Schuman, J
    [J]. GLAUCOMA DIAGNOSIS STRUCTURE AND FUNCTION, 2004, : 71 - 82
  • [8] Comparison of central corneal thickness measurements by ultrasound pachymetry and optical coherence tomography (OCT-3)
    Mills, RP
    Gurses-Ozden, R
    Otani, T
    Lipyanik, J
    Harman, J
    Patella, VM
    Johnstone, M
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U131 - U131
  • [9] Optical Coherence Tomography Pachymetry Mapping in Diagnosis of Keratoconus
    Bayhan, Hasan Ali
    Bayhan, Seray Aslan
    Gurdal, Canan
    Takmaz, Tamer
    Can, Izzet
    [J]. TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2013, 43 (04): : 236 - 240
  • [10] Optical coherence tomography (OCT) can be used to understand and follow advanced glaucoma
    Lee, Seung
    Rajshekhar, Rashmi
    Kim, Eleanor
    de Moraes, Carlos Gustavo
    Ritch, Robert
    Hood, Donald C.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)