Glaucoma Diagnostic Accuracy of Optical Coherence Tomography Parameters in Early Glaucoma with Different Types of Optic Disc Damage

被引:28
|
作者
Shin, Hye-Young [1 ]
Park, Hae-Young Lopilly [2 ]
Jung, Younhea [2 ]
Choi, Jin-A [3 ]
Park, Chan Kee [2 ]
机构
[1] Catholic Univ, Coll Med, Uijeongbu St Marys Hosp, Dept Ophthalmol, Seoul 137701, South Korea
[2] Catholic Univ, Coll Med, Seoul St Marys Hosp, Dept Ophthalmol & Visual Sci, Seoul 137701, South Korea
[3] Catholic Univ, Coll Med, St Vincent Hosp, Dept Ophthalmol, Seoul 137701, South Korea
关键词
VISUAL-FIELD; PROGRESSION; APPEARANCES; PATTERNS; RATES; LAYER;
D O I
10.1016/j.ophtha.2014.04.030
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the initial visual field (VF) defect pattern and the spectral-domain optical coherence tomography (OCT) parameters and investigate the effects of distinct types of optic disc damage on the diagnostic performance of these OCT parameters in early glaucoma. Design: Retrospective, observational study. Participants: A total of 138 control eyes and 160 eyes with early glaucoma were enrolled. The glaucomatous eyes were subdivided into 4 groups according to the type of optic disc damage: focal ischemic (FI) group, myopic (MY) group, senile sclerotic (SS) group, and generalized enlargement (GE) group. Methods: The values of total deviation (TD) maps were analyzed, and superior-inferior (S-I) differences of TD were calculated. The optic nerve head (ONH) parameters, peripapillary retinal nerve fiber layer (pRNFL), and ganglion cell-inner plexiform layer (GCIPL) thicknesses were measured. Main Outcome Measures: Comparison of diagnostic ability using area under the receiver operating characteristic curves (AUCs). Results: The S-I and central S-I difference of the FI group were larger than those of the GE group. The rim area of the SS group was larger than those of the 3 other groups, and the vertical cup-to-disc ratio (CDR) of the GE group was larger than that of the MY group. In addition, the minimum and inferotemporal GCIPL thicknesses of the FI group were smaller than those of the GE group. The AUC of the rim area (0.89) was lower than that of the minimum GCIPL (0.99) in the SS group, and the AUC of the vertical CDR (0.90) was lower than that of the minimum GCIPL (0.99) in the MY group. Furthermore, the AUCs of the minimum GCIPL thicknesses of the FI and MY group were greater than those of the average pRNFL thickness for detecting glaucoma, as opposed to the SS and GE. Conclusions: The OCT parameters differed among the 4 groups on the basis of the distinct optic disc appearance and initial glaucomatous damage pattern. Clinicians should be aware that the diagnostic capability of OCT parameters could differ according to the type of optic disc damage in early glaucoma. (C) 2014 by the American Academy of Ophthalmology.
引用
收藏
页码:1990 / 1997
页数:8
相关论文
共 50 条
  • [31] Optical Coherence Tomography Angiography of Optic Disc and Macula Vessel Density in Glaucoma and Healthy Eyes
    Yip, Vivien C. H.
    Wong, Hon Tym
    Yong, Vernon K. Y.
    Lim, Boon Ang
    Hee, Owen K.
    Cheng, Jun
    Fu, Huazhu
    Lim, Chingwei
    Tay, Elton L. T.
    Loo-Valdez, Roselyn G.
    Teo, Hwei Yee
    Lim, Angela P. H.
    Yip, Leonard W. L.
    JOURNAL OF GLAUCOMA, 2019, 28 (01) : 80 - 87
  • [32] Optical Coherence Tomography Angiography of Optic Disc and Macula Vessel Density in Glaucoma and Healthy Eyes
    Jain, Kanika
    Pegu, Julie
    Bhoot, Madhu
    Dubey, Suneeta
    JOURNAL OF GLAUCOMA, 2019, 28 (07) : E131 - E132
  • [33] Evaluation of clinical disc asymmetry in glaucoma with optical coherence tomography
    Giaconi, JA
    Nouri-Mahdave, K
    Law, SK
    Hoffman, D
    Caprioli, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U450 - U450
  • [34] Diagnostic capability of optical coherence tomography (Stratus OCT 3) in early glaucoma
    Parikh, Raiul S.
    Parikh, Shefali
    Sekhar, G. Chandra
    Kumar, Rajesh S.
    Prabakaran, S.
    Babu, J. Ganesh
    Thomas, Ravi
    OPHTHALMOLOGY, 2007, 114 (12) : 2238 - 2243
  • [35] Optical Coherence Tomography Angiography of Optic Disc in Eyes With Primary Open-angle Glaucoma and Normal-tension Glaucoma
    Toshev, Anani P.
    Schuster, Alexander Karl-Georg
    ul Hassan, Shahzada N.
    Pfeiffer, Norbert
    Hoffmann, Esther M.
    JOURNAL OF GLAUCOMA, 2019, 28 (03) : 243 - 251
  • [36] Comparison of Glaucoma Diagnoses Using Stratus and Cirrus Optical Coherence Tomography in Different Glaucoma Types in a Chinese Population
    Chen, Hsin-Yi
    Chang, Yue-Cune
    Wang, I-Jong
    Chen, Wen-Chi
    JOURNAL OF GLAUCOMA, 2013, 22 (08) : 638 - 646
  • [37] Optical coherence angiography of optic disc in eyes with primary openangle glaucoma and normal tension glaucoma with equal levels of structural damage
    Halkiadakis, Ioannis
    Kollia, Elpida
    Tzimis, Vasilis
    Tzakos, Michalis
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [38] Diagnostic accuracy of optical coherence tomography for diagnosing glaucoma: secondary analyses of the GATE study
    Virgili, Gianni
    Michelessi, Manuele
    Cook, Jonathan
    Boachie, Charles
    Burr, Jennifer
    Banister, Katie
    Garway-Heath, David F.
    Bourne, Rupert R. A.
    Asorey Garcia, Almudena
    Ramsay, Craig R.
    Azuara-Blanco, Augusto
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (05) : 604 - 610
  • [39] Optical Coherence Tomography and Glaucoma
    Geevarghese, Alexi
    Wollstein, Gadi
    Ishikawa, Hiroshi
    Schuman, Joel S.
    ANNUAL REVIEW OF VISION SCIENCE, VOL 7, 2021, 2021, 7 : 693 - 726
  • [40] Diagnostic ability of a linear discriminant function for optic nerve head parameters measured with optical coherence tomography for perimetric glaucoma
    L E Pablo
    A Ferreras
    A B Pajarín
    P Fogagnolo
    Eye, 2010, 24 : 1051 - 1057