Diagnostic capability of optical coherence tomography (Stratus OCT 3) in early glaucoma

被引:91
|
作者
Parikh, Raiul S. [1 ]
Parikh, Shefali [1 ]
Sekhar, G. Chandra [1 ]
Kumar, Rajesh S. [2 ]
Prabakaran, S. [1 ]
Babu, J. Ganesh [1 ]
Thomas, Ravi [1 ]
机构
[1] LV Prasad Eye Inst, Hyderabad 50034, Andhra Pradesh, India
[2] Singapore Eye Res Inst, Singapore, Singapore
关键词
D O I
10.1016/j.ophtha.2007.03.005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the diagnostic capability of optical coherence tomography (Stratus OCT 3) for early glaucoma in Asian Indian eyes. Design: Cross-sectional observational study. Participants: Two groups of patients (early glaucoma and normal) who satisfied the inclusion and exclusion criteria were included. Early glaucoma was diagnosed in presence of open angles, characteristic glaucomatous optic disc changes correlating with the visual field on automated perimetry (visual field defect fulfilling at least 2 of Anderson and Patella's 3 criteria with mean deviation >= -6 dB). Normals had visual acuity >= 20/30, intraocular pressure <22 mmHg with normal optic disc and fields and no ocular abnormality. Methods: All patients underwent complete ophthalmic evaluation including visual field examination (24-2/30-2 SITA standard program) and imaging with Stratus OCT 3. Main Outcome Measures: Sensitivity, specificity, positive and negative predictive values, area under the receiving operating characteristic curve and likelihood ratios were calculated for various Stratus OCT 3 parameters. Results: Seventy-two eyes (72 patients) with early glaucoma and 96 eyes (96 normal subjects) were analyzed. The inferior maximum parameter had the best combination of sensitivity and specificity, 75% (95% confidence interval [Cl], 70.2-79.8%) and 89.6% (95% Cl, 82.6-96.6%), respectively. The 6-o'clock parameter had a sensitivity of 61.1% (95% Cl, 52.3-69.9) and specificity of 99% (95% Cl, 95-100); for an assumed prevalence of 5%, the positive and negative predictive values were 75% and 98%, respectively. The positive likelihood ratio for the 6-o'clock parameter (P<5%) in early glaucoma was 61. Conclusions: Optical coherence tomography has moderate sensitivity with high specificity for the diagnosis of early glaucoma and may have a potential role in screening.
引用
收藏
页码:2238 / 2243
页数:6
相关论文
共 50 条
  • [1] Diagnostic capability of macular parameters of Stratus OCT 3 in detection of early glaucoma
    Parikh, R. S.
    Parikh, S. R.
    Thomas, R.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (02) : 197 - 201
  • [2] Comparison of Glaucoma Diagnostic Capabilities of Cirrus HD and Stratus Optical Coherence Tomography
    Park, Seong Bae
    Sung, Kyung Rim
    Kang, Sung Yong
    Kim, Kyung Ri
    Kook, Michael S.
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2009, 127 (12) : 1603 - 1609
  • [3] Diagnostic Capability of Spectral-Domain Optical Coherence Tomography for Glaucoma
    Wu, Huijuan
    De Boer, Johannes F.
    Chen, Teresa C.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (05) : 815 - 826
  • [4] Optical Coherence Tomography (OCT) in Glaucoma Diagnostics
    Hoffmann, E. M.
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2012, 229 (02) : 135 - 142
  • [5] Diagnostic capability of Fourier-Domain optical coherence tomography in early primary open angle glaucoma
    Fang Yuan
    Pan Ying-zi
    Li Mei
    Qiao Rong-hua
    Cai Yu
    [J]. CHINESE MEDICAL JOURNAL, 2010, 123 (15) : 2045 - 2050
  • [6] Diagnostic capability of Fourier-Domain optical coherence tomography in early primary open angle glaucoma
    FANG Yuan PAN Yingzi LI Mei QIAO Ronghua and CAI Yu Department of Ophthalmology Peking University First Hospital Beijing China
    [J]. 中华医学杂志(英文版), 2010, (15) : 2045 - 2050
  • [7] Cirrus High-Definition Optical Coherence Tomography Compared with Stratus Optical Coherence Tomography in Glaucoma Diagnosis
    Moreno-Montanes, Javier
    Olmo, Natalia
    Alvarez, Aurora
    Garcia, Noelia
    Zarranz-Ventura, Javier
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (01) : 335 - 343
  • [8] Glaucoma detection using different Stratus optical coherence tomography protocols
    Hougaard, Jesper Leth
    Heijl, Anders
    Bengtsson, Boel
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (03): : 251 - 256
  • [9] Comparison between GDx VCC scanning laser polarimetry and Stratus OCT optical coherence tomography in the diagnosis of chronic glaucoma
    Brusini, Paolo
    Salvetat, Maria L.
    Zeppieri, Marco
    Tosoni, Claudia
    Parisi, Lucia
    Felletti, Mirella
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 2006, 84 (05): : 650 - 655
  • [10] Macular parameters of Stratus optical coherence tomography for assessing glaucoma in high myopia
    Hung, Kuo-Chi
    Wu, Pei-Chang
    Chang, Hsueh-Wen
    Lai, Ing-Chou
    Tsai, Jen-Chia
    Lin, Pei-Wen
    Teng, Mei-Ching
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2015, 98 (01) : 39 - 44