Glaucoma detection using different Stratus optical coherence tomography protocols

被引:19
|
作者
Hougaard, Jesper Leth [1 ]
Heijl, Anders [1 ]
Bengtsson, Boel [1 ]
机构
[1] Malmo Univ Hosp, Univ Lund, Dept Clin Sci, SE-20502 Malmo, Sweden
来源
ACTA OPHTHALMOLOGICA SCANDINAVICA | 2007年 / 85卷 / 03期
关键词
diagnosis; glaucoma; optical coherence tomography; retinal nerve fibre layer; Stratus OCT;
D O I
10.1111/j.1600-0420.2006.00826.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To examine and compare the diagnostic accuracy of retinal nerve fibre layer (RNFL) thickness measurements using different Stratus optical coherence tomography (OCT) scanning protocols. Stratus OCT data for 90 healthy subjects and 62 glaucoma patients with mild or moderate visual field loss were prospectively collected and analysed using four RNFL thickness protocols that differed in terms of image resolution and number of scans. Cut-off levels corrected for age and refractive error were defined by reference values derived from an independent normal database. Sensitivity and specificity were calculated for average RNFL thickness for the full circle scan, and for the quadrant and clock hour circle scan sectors at p < 5% and p < 1% cut-off values. Regular- and high-resolution images performed equally well, and single best-quality scans were as good as the average of three scans to distinguish between healthy and glaucomatous eyes. Full circle RNFL thickness yielded similar or better diagnostic accuracy than that of sectors. Sensitivities ranged from 84% to 87% and specificities from 89% to 93% for full circle RNFL thickness at the p < 5% cut-off level. The abilities of four different Stratus OCT RNFL thickness protocols to distinguish between eyes with predominantly mild glaucomatous field loss and healthy eyes were very similar. Thus diagnostic accuracy did not differ between high- and regular-resolution protocols, nor between global (full circle) and localized (sector) OCT parameters, which suggests a diffuse component in early glaucomatous RNFL damage.
引用
收藏
页码:251 / 256
页数:6
相关论文
共 50 条
  • [1] Comparison of Glaucoma Diagnoses Using Stratus and Cirrus Optical Coherence Tomography in Different Glaucoma Types in a Chinese Population
    Chen, Hsin-Yi
    Chang, Yue-Cune
    Wang, I-Jong
    Chen, Wen-Chi
    [J]. JOURNAL OF GLAUCOMA, 2013, 22 (08) : 638 - 646
  • [2] Comparison of different stratus OCT protocols for glaucoma detection
    Vessani, RM
    Raiza, AP
    Hatanaka, M
    Susanna, R
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [3] Logistic regression analysis for glaucoma diagnosis using stratus optical coherence tomography
    Chen, Hsin-Yi
    Huang, Mei-Ling
    Hung, Por-Tying
    [J]. OPTOMETRY AND VISION SCIENCE, 2006, 83 (07) : 527 - 534
  • [4] Analysis of Glaucoma Diagnosis with Automated Classifiers using Stratus Optical Coherence Tomography
    Mei-Ling Huang
    Hsin-Yi Chen
    Por-Tying Hung
    [J]. Optical and Quantum Electronics, 2005, 37 : 1239 - 1249
  • [5] Logistic regression analysis for glaucoma diagnosis using stratus optical coherence tomography
    Huang, ML
    Lin, JC
    Chen, HY
    [J]. APBP 2004: SECOND ASIAN AND PACIFIC RIM SYMPOSIUM ON BIOPHOTONICS, PROCEEDINGS, 2004, : 151 - 152
  • [6] Analysis of glaucoma diagnosis with automated classifiers using stratus optical coherence tomography
    Huang, ML
    Chen, HY
    Hung, PT
    [J]. OPTICAL AND QUANTUM ELECTRONICS, 2005, 37 (13-15) : 1239 - 1249
  • [7] Development and comparison of automated classifiers for glaucoma diagnosis using stratus optical coherence tomography
    Huang, ML
    Chen, HY
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (11) : 4121 - 4129
  • [8] Cirrus High-Definition Optical Coherence Tomography Compared with Stratus Optical Coherence Tomography in Glaucoma Diagnosis
    Moreno-Montanes, Javier
    Olmo, Natalia
    Alvarez, Aurora
    Garcia, Noelia
    Zarranz-Ventura, Javier
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (01) : 335 - 343
  • [9] Macular parameters of Stratus optical coherence tomography for assessing glaucoma in high myopia
    Hung, Kuo-Chi
    Wu, Pei-Chang
    Chang, Hsueh-Wen
    Lai, Ing-Chou
    Tsai, Jen-Chia
    Lin, Pei-Wen
    Teng, Mei-Ching
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2015, 98 (01) : 39 - 44
  • [10] Diagnostic capability of optical coherence tomography (Stratus OCT 3) in early glaucoma
    Parikh, Raiul S.
    Parikh, Shefali
    Sekhar, G. Chandra
    Kumar, Rajesh S.
    Prabakaran, S.
    Babu, J. Ganesh
    Thomas, Ravi
    [J]. OPHTHALMOLOGY, 2007, 114 (12) : 2238 - 2243