Glaucoma Diagnostic Accuracy of Optical Coherence Tomography Parameters in Early Glaucoma with Different Types of Optic Disc Damage

被引:28
|
作者
Shin, Hye-Young [1 ]
Park, Hae-Young Lopilly [2 ]
Jung, Younhea [2 ]
Choi, Jin-A [3 ]
Park, Chan Kee [2 ]
机构
[1] Catholic Univ, Coll Med, Uijeongbu St Marys Hosp, Dept Ophthalmol, Seoul 137701, South Korea
[2] Catholic Univ, Coll Med, Seoul St Marys Hosp, Dept Ophthalmol & Visual Sci, Seoul 137701, South Korea
[3] Catholic Univ, Coll Med, St Vincent Hosp, Dept Ophthalmol, Seoul 137701, South Korea
关键词
VISUAL-FIELD; PROGRESSION; APPEARANCES; PATTERNS; RATES; LAYER;
D O I
10.1016/j.ophtha.2014.04.030
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the initial visual field (VF) defect pattern and the spectral-domain optical coherence tomography (OCT) parameters and investigate the effects of distinct types of optic disc damage on the diagnostic performance of these OCT parameters in early glaucoma. Design: Retrospective, observational study. Participants: A total of 138 control eyes and 160 eyes with early glaucoma were enrolled. The glaucomatous eyes were subdivided into 4 groups according to the type of optic disc damage: focal ischemic (FI) group, myopic (MY) group, senile sclerotic (SS) group, and generalized enlargement (GE) group. Methods: The values of total deviation (TD) maps were analyzed, and superior-inferior (S-I) differences of TD were calculated. The optic nerve head (ONH) parameters, peripapillary retinal nerve fiber layer (pRNFL), and ganglion cell-inner plexiform layer (GCIPL) thicknesses were measured. Main Outcome Measures: Comparison of diagnostic ability using area under the receiver operating characteristic curves (AUCs). Results: The S-I and central S-I difference of the FI group were larger than those of the GE group. The rim area of the SS group was larger than those of the 3 other groups, and the vertical cup-to-disc ratio (CDR) of the GE group was larger than that of the MY group. In addition, the minimum and inferotemporal GCIPL thicknesses of the FI group were smaller than those of the GE group. The AUC of the rim area (0.89) was lower than that of the minimum GCIPL (0.99) in the SS group, and the AUC of the vertical CDR (0.90) was lower than that of the minimum GCIPL (0.99) in the MY group. Furthermore, the AUCs of the minimum GCIPL thicknesses of the FI and MY group were greater than those of the average pRNFL thickness for detecting glaucoma, as opposed to the SS and GE. Conclusions: The OCT parameters differed among the 4 groups on the basis of the distinct optic disc appearance and initial glaucomatous damage pattern. Clinicians should be aware that the diagnostic capability of OCT parameters could differ according to the type of optic disc damage in early glaucoma. (C) 2014 by the American Academy of Ophthalmology.
引用
收藏
页码:1990 / 1997
页数:8
相关论文
共 50 条
  • [11] Diagnostic accuracy of posterior pole asymmetry analysis parameters of spectralis optical coherence tomography in detecting early unilateral glaucoma
    Dave, Paaraj
    Shah, Juhi
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2015, 63 (11) : 837 - 842
  • [12] Glaucoma Diagnostic Capabilities of Optic Nerve Head Parameters as Determined by Cirrus HD Optical Coherence Tomography
    Sung, Kyung Rim
    Na, Jung Hwa
    Lee, Youngrok
    JOURNAL OF GLAUCOMA, 2012, 21 (07) : 498 - 504
  • [13] Diagnostic Accuracy and Detection Rate of Glaucoma Screening with Optic Disk Photos, Optical Coherence Tomography Images, and Telemedicine
    Anton, Alfonso
    Nolivos, Karen
    Pazos, Marta
    Fatti, Gianluca
    Ayala, Miriam Eleonora
    Martinez-Prats, Elena
    Peral, Oscar
    Poposki, Vladimir
    Tsiroukis, Evangelos
    Morilla-Grasa, Antonio
    Comas, Merce
    Castells, Xavier
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (01)
  • [14] Identifying early glaucoma with optical coherence tomography
    Nouri-Mahdavi, K
    Hoffman, D
    Tannenbaum, DP
    Law, SK
    Caprioli, J
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (02) : 228 - 235
  • [15] Effect of Disease Severity and Optic Disc Size on Diagnostic Accuracy of RTVue Spectral Domain Optical Coherence Tomograph in Glaucoma
    Rao, Harsha L.
    Leite, Mauro T.
    Weinreb, Robert N.
    Zangwill, Linda M.
    Alencar, Luciana M.
    Sample, Pamela A.
    Medeiros, Felipe A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (03) : 1290 - 1296
  • [16] Prediction of Glaucoma Progression with Structural Parameters: Comparison of Optical Coherence Tomography and Clinical Disc Parameters
    Daneshvar, Ramin
    Yarmohammadi, Adeleh
    Alizadeh, Reza
    Henry, Sharon
    Law, Simon K.
    Caprioli, Joseph
    Nouri-Mahdavi, Kouros
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 208 : 19 - 29
  • [17] Correlation between Disc Damage Likelihood Scale and Optical Coherence Tomography in the Diagnosis of Glaucoma
    Majid, Aman Shah B. Abdul
    Kwag, Jee Hyun
    Jung, Sang Hoon
    Yim, Hye Bin
    Kim, Yeon Deok
    Kang, Kui Dong
    OPHTHALMOLOGICA, 2010, 224 (05) : 274 - 282
  • [18] Effect of high myopia on glaucoma diagnostic parameters measured with optical coherence tomography
    Kita, Yoshiyuki
    Kita, Ritsuko
    Takeyama, Asuka
    Tomita, Goji
    Goldberg, Ivan
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 (08): : 722 - 728
  • [19] Glaucoma Diagnostic Ability of the Optical Coherence Tomography Angiography Vessel Density Parameters
    Chung, Jae Keun
    Hwang, Young Hoon
    Wi, Jae Min
    Kim, Mijin
    Jung, Jong Jin
    CURRENT EYE RESEARCH, 2017, 42 (11) : 1458 - 1467
  • [20] Value of optical coherence tomography measurement of macular thickness and optic disc parameters for glaucoma screening in patients with high myopia
    Mu, Hua
    Li, Rui-Shu
    Yin, Zhen
    Feng, Zhuo-Lei
    WORLD JOURNAL OF CLINICAL CASES, 2023, 11 (14) : 3187 - 3194