Correlation between Disc Damage Likelihood Scale and Optical Coherence Tomography in the Diagnosis of Glaucoma

被引:14
|
作者
Majid, Aman Shah B. Abdul [1 ]
Kwag, Jee Hyun [2 ]
Jung, Sang Hoon [3 ]
Yim, Hye Bin [4 ]
Kim, Yeon Deok [5 ]
Kang, Kui Dong [1 ]
机构
[1] Univ Oxford, Oxford Eye Hosp, Dept Ophthalmol, Oxford, England
[2] Korea Univ, Dept Brain & Cognit Engn, Seoul, South Korea
[3] Gangneung Inst, Korea Inst Sci & Technol, Kangnung, South Korea
[4] Catholic Univ Korea, Incheon St Marys Hosp, Coll Med, Dept Ophthalmol, Inchon, South Korea
[5] HanGil Eye Hosp, Inchon, South Korea
关键词
Disc damage likelihood scale; Glaucoma; Optical coherence tomography; HEIDELBERG-RETINA-TOMOGRAPH; RATIO;
D O I
10.1159/000287350
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the relationship between the Disc Damage Likelihood Scale (DDLS), visual field and various optical coherence tomography (OCT) parameters for glaucoma diagnosis. Methods: The study comprised 149 eyes from 149 patients. The patients were categorized as normal, glaucoma suspect or with glaucoma. They were clinically examined and graded according to the DDLS system. OCT was performed to acquire both a retinal nerve fibre layer analysis and an optic nerve head analysis. The relationships between DDLS score, visual field and OCT parameters were analysed using multiple correlation analysis. Results: The normal, glaucoma suspect and glaucoma groups had average DDLS scores of 1.58 +/- 1.40, 2.55 +/- 1.93 and 5.33 +/- 1.39, respectively. Evaluating the area under the receiver operator characteristic curve, the DDLS had the best predictive power (0.917), followed by corrected pattern standard deviation. Conclusion: The DDLS is a useful parameter in the diagnosis of glaucoma and it showed a close correlation with visual field, cup/disc ratio and OCT parameters. Copyright (C) 2010 S. Karger AG, Basel
引用
收藏
页码:274 / 282
页数:9
相关论文
共 50 条
  • [1] Assessment of Disc Damage Likelihood Scale (DDLS) for Automated Glaucoma Diagnosis
    Singh, Rana Uday
    Gujral, Shruthi
    COMPLEX ADAPTIVE SYSTEMS, 2014, 36 : 490 - +
  • [2] Regression Analysis of Optical Coherence Tomography Disc Variables for Glaucoma Diagnosis
    Richter, Grace M.
    Zhang, Xinbo
    Tan, Ou
    Francis, Brian A.
    Chopra, Vikas
    Greenfield, David S.
    Varma, Rohit
    Schuman, Joel S.
    Huang, David
    JOURNAL OF GLAUCOMA, 2016, 25 (08) : 634 - 642
  • [3] Optical coherence tomography and optical coherence tomography angiography in glaucoma: diagnosis, progression, and correlation with functional tests
    Triolo, Giacinto
    Rabiolo, Alessandro
    THERAPEUTIC ADVANCES IN OPHTHALMOLOGY, 2020, 12
  • [4] Optical Coherence Tomography in Glaucoma Diagnosis
    Brinkmann, C. K.
    OPHTHALMOLOGE, 2015, 112 (08): : 624 - 625
  • [5] Comparison of disc damage likelihood scale, cup to disc ratio, and Heidelberg retina tomograph in the diagnosis of glaucoma
    Danesh-Meyer, HV
    Gaskin, BJ
    Jayusundera, T
    Donaldson, M
    Gamble, GD
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (04) : 437 - 441
  • [6] Correlation between Optic Nerve Parameters Obtained Using 3D Nonmydriatic Retinal Camera and Optical Coherence Tomography: Interobserver Agreement on the Disc Damage Likelihood Scale
    Han, Jae Wook
    Cho, Soon Young
    Kang, Kui Dong
    JOURNAL OF OPHTHALMOLOGY, 2014, 2014
  • [7] Likelihood Ratios for Glaucoma Diagnosis Using Spectral-Domain Optical Coherence Tomography
    Lisboa, Renato
    Mansouri, Kaweh
    Zangwill, Linda M.
    Weinreb, Robert N.
    Medeiros, Felipe A.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (05) : 918 - 926
  • [8] Optical Coherence Tomography for the Diagnosis and Monitoring of Glaucoma
    Ha, Ahnul
    Park, Ki Ho
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2019, 8 (02): : 135 - 145
  • [9] Glaucoma Diagnostic Accuracy of Optical Coherence Tomography Parameters in Early Glaucoma with Different Types of Optic Disc Damage
    Shin, Hye-Young
    Park, Hae-Young Lopilly
    Jung, Younhea
    Choi, Jin-A
    Park, Chan Kee
    OPHTHALMOLOGY, 2014, 121 (10) : 1990 - 1997
  • [10] Evaluation of clinical disc asymmetry in glaucoma with optical coherence tomography
    Giaconi, JA
    Nouri-Mahdave, K
    Law, SK
    Hoffman, D
    Caprioli, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U450 - U450