Glaucoma Diagnostic Accuracy of Optical Coherence Tomography Parameters in Early Glaucoma with Different Types of Optic Disc Damage

被引:28
|
作者
Shin, Hye-Young [1 ]
Park, Hae-Young Lopilly [2 ]
Jung, Younhea [2 ]
Choi, Jin-A [3 ]
Park, Chan Kee [2 ]
机构
[1] Catholic Univ, Coll Med, Uijeongbu St Marys Hosp, Dept Ophthalmol, Seoul 137701, South Korea
[2] Catholic Univ, Coll Med, Seoul St Marys Hosp, Dept Ophthalmol & Visual Sci, Seoul 137701, South Korea
[3] Catholic Univ, Coll Med, St Vincent Hosp, Dept Ophthalmol, Seoul 137701, South Korea
关键词
VISUAL-FIELD; PROGRESSION; APPEARANCES; PATTERNS; RATES; LAYER;
D O I
10.1016/j.ophtha.2014.04.030
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the initial visual field (VF) defect pattern and the spectral-domain optical coherence tomography (OCT) parameters and investigate the effects of distinct types of optic disc damage on the diagnostic performance of these OCT parameters in early glaucoma. Design: Retrospective, observational study. Participants: A total of 138 control eyes and 160 eyes with early glaucoma were enrolled. The glaucomatous eyes were subdivided into 4 groups according to the type of optic disc damage: focal ischemic (FI) group, myopic (MY) group, senile sclerotic (SS) group, and generalized enlargement (GE) group. Methods: The values of total deviation (TD) maps were analyzed, and superior-inferior (S-I) differences of TD were calculated. The optic nerve head (ONH) parameters, peripapillary retinal nerve fiber layer (pRNFL), and ganglion cell-inner plexiform layer (GCIPL) thicknesses were measured. Main Outcome Measures: Comparison of diagnostic ability using area under the receiver operating characteristic curves (AUCs). Results: The S-I and central S-I difference of the FI group were larger than those of the GE group. The rim area of the SS group was larger than those of the 3 other groups, and the vertical cup-to-disc ratio (CDR) of the GE group was larger than that of the MY group. In addition, the minimum and inferotemporal GCIPL thicknesses of the FI group were smaller than those of the GE group. The AUC of the rim area (0.89) was lower than that of the minimum GCIPL (0.99) in the SS group, and the AUC of the vertical CDR (0.90) was lower than that of the minimum GCIPL (0.99) in the MY group. Furthermore, the AUCs of the minimum GCIPL thicknesses of the FI and MY group were greater than those of the average pRNFL thickness for detecting glaucoma, as opposed to the SS and GE. Conclusions: The OCT parameters differed among the 4 groups on the basis of the distinct optic disc appearance and initial glaucomatous damage pattern. Clinicians should be aware that the diagnostic capability of OCT parameters could differ according to the type of optic disc damage in early glaucoma. (C) 2014 by the American Academy of Ophthalmology.
引用
收藏
页码:1990 / 1997
页数:8
相关论文
共 50 条
  • [1] Optical Coherence Tomography Angiography of Optic Disc Perfusion in Glaucoma
    Jia, Yali
    Wei, Eric
    Wang, Xiaogang
    Zhang, Xinbo
    Morrison, John C.
    Parikh, Mansi
    Lombardi, Lori H.
    Gattey, Devin M.
    Armour, Rebecca L.
    Edmunds, Beth
    Kraus, Martin F.
    Fujimoto, James G.
    Huang, David
    OPHTHALMOLOGY, 2014, 121 (07) : 1322 - 1332
  • [2] Optic disc area in different types of glaucoma
    Oya Tekeli
    Esra Savku
    Ahmed Abdullayev
    International Journal of Ophthalmology, 2016, (08) : 1134 - 1137
  • [3] Optic disc area in different types of glaucoma
    Tekeli, Oya
    Savku, Esra
    Abdullayev, Ahmed
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (08) : 1134 - 1137
  • [4] OPTIC DISC MORPHOLOGY IN DIFFERENT TYPES OF GLAUCOMA
    JONAS, JB
    XU, L
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 761 - 761
  • [5] Optical coherence tomography angiography findings of an optic disc melanocytoma in a glaucoma eye
    Yoshiyuki Kita
    Gábor Hollό
    Akiko Murai
    Ritsuko Kita
    Akito Hirakata
    International Ophthalmology, 2019, 39 : 677 - 682
  • [6] Glaucoma Progression After Initial Optic Disc Hemorrhage by Optical Coherence Tomography
    Suh, M.
    Park, K.
    Kim, H.
    Kim, T. -W.
    Kim, S. -Y.
    Kim, D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [7] Optical Coherence Tomography Versus Optic Disc Photo Assessment in Glaucoma Screening
    Beniz, Luiz Arthur F.
    Campos, Veronica P.
    Medeiros, Felipe A.
    JOURNAL OF GLAUCOMA, 2024, 33 : S21 - S25
  • [8] Optical coherence tomography angiography findings of an optic disc melanocytoma in a glaucoma eye
    Kita, Yoshiyuki
    Hollo, Gabor
    Murai, Akiko
    Kita, Ritsuko
    Hirakata, Akito
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (03) : 677 - 682
  • [9] Influence of Disc Size on the Diagnostic Accuracy of Cirrus Spectral-Domain Optical Coherence Tomography in Glaucoma
    Sato, Shino
    Ukegawa, Kaori
    Nitta, Eri
    Hirooka, Kazuyuki
    JOURNAL OF OPHTHALMOLOGY, 2018, 2018
  • [10] The quality of reporting of diagnostic accuracy studies of optical coherence tomography in glaucoma
    Johnson, Zoe K.
    Siddiqui, M. A. Rehman
    Azuara-Blanco, Augusto
    OPHTHALMOLOGY, 2007, 114 (09) : 1607 - 1612