The quality of reporting of diagnostic accuracy studies of optical coherence tomography in glaucoma

被引:20
|
作者
Johnson, Zoe K.
Siddiqui, M. A. Rehman
Azuara-Blanco, Augusto
机构
[1] Grampian Univ Hosp, Natl Hlth Serv Trust, Dept Ophthalmol, Aberdeen, Scotland
[2] Univ Aberdeen, Hlth Serv Res Unit, Aberdeen, Scotland
关键词
D O I
10.1016/j.ophtha.2006.11.036
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To evaluate the quality of reporting of diagnostic accuracy studies using optical coherence tomography (OCT) in glaucoma. Design: Descriptive series of published studies. Participants: Published studies reporting a measure of the diagnostic accuracy of OCT for glaucoma. Methods: Review of English language papers reporting measures of diagnostic accuracy of OCT for glaucoma. Papers were identified from a Medline literature search performed in June 2006. Articles were appraised using the 25 items provided by the Standards for Reporting of Diagnostic Accuracy (STARD) initiative. Each item was recorded as full, partially, or not reported. Main Outcome Measures: Degree of compliance with the STARD guidelines. Results: Thirty papers were appraised. Eight papers (26.7%) fully reported more than half of the STARD items. The lowest number of fully reported items in a study was 5 and the highest was 17. Descriptions of key aspects of methodology frequently were missing. For example, details of participant sampling (e.g., consecutive or random selection) were described in only 8 (26.7%) of 30 publications. Measures of statistical uncertainty were reported in 18 (60%) of 30 publications. No single STARD item was fully reported by all the papers. Conclusions: The standard of reporting of diagnostic accuracy studies in glaucoma using OCT was suboptimal. It is hoped that adoption of the STARD guidelines will lead to an improvement in reporting of diagnostic accuracy studies, enabling clearer evidence to be produced for the usefulness of OCT for the diagnosis of glaucoma. Ophthalmology 2007,;114:1607-1612 (c) 2007 by the American Academy of Ophthalmology.
引用
收藏
页码:1607 / 1612
页数:6
相关论文
共 50 条
  • [1] Effect of Scan Quality on Diagnostic Accuracy of Spectral-Domain Optical Coherence Tomography in Glaucoma
    Rao, Harsha L.
    Addepalli, Uday K.
    Yadav, Ravi K.
    Senthil, Sirisha
    Choudhari, Nikhil S.
    Garudadri, Chandra S.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (03) : 719 - 727
  • [2] Diagnostic Accuracy of Optical Coherence Tomography and Scanning Laser Tomography for Identifying Glaucoma in Myopic Eyes
    Malik, Rizwan
    Belliveau, Anne C.
    Sharpe, Glen P.
    Shuba, Lesya M.
    Chauhan, Balwantray C.
    Nicolela, Marcelo T.
    [J]. OPHTHALMOLOGY, 2016, 123 (06) : 1181 - 1189
  • [3] Quality of the Reporting of Diagnostic Accuracy Studies: STARD (Standards for the Reporting of Diagnostic accuracy studies)
    Tackmann, R.
    Schuetz, G.
    Hamm, B.
    Dewey, M.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (08): : 655 - 659
  • [4] Diagnostic accuracy of optical coherence tomography for diagnosing glaucoma: secondary analyses of the GATE study
    Virgili, Gianni
    Michelessi, Manuele
    Cook, Jonathan
    Boachie, Charles
    Burr, Jennifer
    Banister, Katie
    Garway-Heath, David F.
    Bourne, Rupert R. A.
    Asorey Garcia, Almudena
    Ramsay, Craig R.
    Azuara-Blanco, Augusto
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (05) : 604 - 610
  • [5] The quality of reporting of diagnostic accuracy studies in glaucoma using scanning laser polarimetry
    Paranjothy, Bhuma
    Shunmugam, Manoharan
    Azuara-Blanco, Augusto
    [J]. JOURNAL OF GLAUCOMA, 2007, 16 (08) : 670 - 675
  • [6] The quality of reporting of diagnostic accuracy studies in glaucoma using the Heidelberg retina tomograph
    Shunmugam, Manobaran
    Azuara-Blanco, Augusto
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (06) : 2317 - 2323
  • [7] Quality of reporting of diagnostic accuracy studies
    Smidt, N
    Rutjes, AWS
    van der Windt, DAWM
    Ostelo, RWJG
    Reitsma, JB
    Bossuyt, PM
    Bouter, LM
    de Vet, HCW
    [J]. RADIOLOGY, 2005, 235 (02) : 347 - 353
  • [8] The Diagnostic Value of Optical Coherence Tomography Angiography in Glaucoma
    Koutropoulou, Nikolitsa
    Panos, Georgios D.
    [J]. CURRENT MEDICAL IMAGING, 2021, 17 (10) : 1179 - 1182
  • [9] Diagnostic Performance of Optical Coherence Tomography for Pseudoexfoliation Glaucoma
    Ozcelik-Kose, Alev
    Yildiz, Merve B.
    Imamoglu, Serhat
    [J]. JOURNAL OF GLAUCOMA, 2022, 31 (08) : 651 - 658
  • [10] Glaucoma Diagnostic Accuracy of Optical Coherence Tomography Parameters in Early Glaucoma with Different Types of Optic Disc Damage
    Shin, Hye-Young
    Park, Hae-Young Lopilly
    Jung, Younhea
    Choi, Jin-A
    Park, Chan Kee
    [J]. OPHTHALMOLOGY, 2014, 121 (10) : 1990 - 1997