The quality of reporting of diagnostic accuracy studies in glaucoma using the Heidelberg retina tomograph

被引:20
|
作者
Shunmugam, Manobaran [1 ]
Azuara-Blanco, Augusto [1 ]
机构
[1] Univ Aberdeen, Grampian Univ Hosp Natl Hlth Serv Trust, Dept Ophthalmol, Aberdeen AB9 1FX, Scotland
关键词
D O I
10.1167/iovs.05-1250
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Scanning laser tomography with the Heidelberg retina tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany) has been proposed as a useful diagnostic test for glaucoma. This study was conducted to evaluate the quality of reporting of published studies using the HRT for diagnosing glaucoma. METHODS. A validated Medline and hand search of English-language articles reporting on measures of diagnostic accuracy of the HRT for glaucoma was performed. Two reviewers selected and appraised the papers independently. The Standards for Reporting of Diagnostic Accuracy (STARD) checklist was used to evaluate the quality of each publication. RESULTS. A total of 29 articles were included. Interobserver rating agreement was observed in 83% of items (K = 0.76). The number of STARD items properly reported ranged from 5 to 18. Less than a third of studies (7/29) explicitly reported more than half of the STARD items. Descriptions of key aspects of the methodology were frequently missing. For example, the design of the study (prospective or retrospective) was reported in 6 of 29 studies, and details of participant sampling (e.g., consecutive or random selection) were described in 5 of 29 publications. The commonest description of diagnostic accuracy was sensitivity and specificity (25/29) followed by area under the ROC curve (13/29), with 9 of 29 publications reporting both. CONCLUSIONS. The quality of reporting of diagnostic accuracy tests for glaucoma with HRT is suboptimal. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies.
引用
收藏
页码:2317 / 2323
页数:7
相关论文
共 50 条
  • [1] Diagnostic Accuracy of the Heidelberg Retina Tomograph for Glaucoma A Population-Based Assessment
    Healey, Paul R.
    Lee, Anne J.
    Aung, Tin
    Wong, Tien Y.
    Mitchell, Paul
    OPHTHALMOLOGY, 2010, 117 (09) : 1667 - 1673
  • [2] Diagnostic ability of the Heidelberg Retina Tomograph 3 for glaucoma
    Ferreras, Antonio
    Pablo, Luis E.
    Pajarin, Ana B.
    Larrosa, Jose M.
    Polo, Vicente
    Pueyo, Victoria
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (02) : 354 - 359
  • [3] Diagnostic accuracy of the Moorfields Regression Analysis using the Heidelberg Retina Tomograph in glaucoma patients with visual field defects
    Medved, N.
    Cvenkel, B.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2007, 17 (02) : 216 - 222
  • [4] Heidelberg Retina Tomograph for the Detection of Glaucoma
    Cvenkel, Barbara
    ZDRAVNISKI VESTNIK-SLOVENIAN MEDICAL JOURNAL, 2012, 81 : I157 - I169
  • [5] Comparison of diagnostic accuracy of heidelberg retina tomograph II and heidelberg retina tomograph 3 to discriminate glaucomatous and nonglaucomatous eyes
    De Leon-Ortega, Julio E.
    Sakata, Lisandro M.
    Monheit, Blythe E.
    Mcgwin, Gerald, Jr.
    Arthur, Stella N.
    Girkin, Christopher A.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (04) : 525 - 532
  • [6] The effect of disc size and severity of disease on the diagnostic accuracy of the Heidelberg retina tomograph glaucoma probability score
    Zangwill, Linda M.
    Jain, Sonia
    Racette, Lyne
    Ernstrom, Karin B.
    Bowd, Christopher
    Medeiros, Felipe A.
    Sample, Pamela A.
    Weinreb, Robert N.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (06) : 2653 - 2660
  • [7] Glaucoma Structural Progression by using Heidelberg Retina Tomograph (HRT)
    Iester, Michele M.
    Aribas, Laura Gil
    Traverso, Carlo Enrico
    Perdicchi, Andrea
    Frezzotti, Paolo
    Ferreras, Antonio
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [8] New developments in Heidelberg retina tomograph for glaucoma
    Strouthidis, Nicholas G.
    Garway-Heath, David F.
    CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (02) : 141 - 148
  • [9] Glaucoma detection with the Heidelberg retina tomograph 3
    Burgansky-Eliash, Zvia
    Wollstein, Gadi
    Bilonick, Richard A.
    Ishikawa, Hiroshi
    Kagemann, Larry
    Schuman, Joel S.
    OPHTHALMOLOGY, 2007, 114 (03) : 466 - 471
  • [10] Diagnostic accuracy of Heidelberg Retina Tomograph III classifications in a Turkish primary open-angle glaucoma population
    Bozkurt, Banu
    Irkec, Murat
    Arslan, Umut
    ACTA OPHTHALMOLOGICA, 2010, 88 (01) : 125 - 130