Correlation between Optic Nerve Parameters Obtained Using 3D Nonmydriatic Retinal Camera and Optical Coherence Tomography: Interobserver Agreement on the Disc Damage Likelihood Scale

被引:11
|
作者
Han, Jae Wook [1 ]
Cho, Soon Young [1 ]
Kang, Kui Dong [1 ]
机构
[1] Catholic Univ Korea, Incheon St Marys Hosp, Coll Med, Dept Ophthalmol, Inchon 403720, South Korea
关键词
VISUAL-FIELD; GLAUCOMA;
D O I
10.1155/2014/931738
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare stereometric parameters obtained by three-dimensional (3D) optic disc photography and optical coherence tomography (OCT) and assess interobserver agreement on the disc damage likelihood scale (DDLS). Methods. This retrospective study included 190 eyes from 190 patients classified as normal, glaucoma suspect, or glaucomatous. Residents at different levels of training completed the DDLS for each patient before and after attending a training module. 3D optic disc photography and OCT were performed on each eye, and correlations between the DDLS and various parameters obtained by each device were calculated. Results. We found moderate agreement (weighted kappa value, 0.59 +/- 0.03) between DDLS scores obtained by 3D optic disc photography and the glaucoma specialist. The weighted kappa values for agreement and interobserver concordance increased among residents after the training module. Interobserver concordance was the poorest at DDLS stages 5 and 6. The DDLS scored by the glaucoma specialist had the highest predictability value (0.941). Conclusions. The DDLS obtained by 3D optic disc photography is a useful diagnostic tool for glaucoma. A supervised teaching program increased trainee interobserver agreement on the DDLS. DDLS stages 5 and 6 showed the poorest interobserver agreement, suggesting that caution is required when recording these stages.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Correlation between Disc Damage Likelihood Scale and Optical Coherence Tomography in the Diagnosis of Glaucoma
    Majid, Aman Shah B. Abdul
    Kwag, Jee Hyun
    Jung, Sang Hoon
    Yim, Hye Bin
    Kim, Yeon Deok
    Kang, Kui Dong
    OPHTHALMOLOGICA, 2010, 224 (05) : 274 - 282
  • [2] The correlation between rat retinal nerve fiber layer thickness around optic disc by using optical coherence tomography and histological measurements
    Ju-Fang Huang
    Hui-Min Yu
    Lei Shang
    Ruo-Fei Ma
    Ngobe Akume Cynthia
    Yan-Qun Cao
    Jia Luo
    Le-Ping Zeng
    Dan Chen
    Kun Xiong
    International Journal of Ophthalmology, 2013, (04) : 415 - 421
  • [3] The correlation between rat retinal nerve fiber layer thickness around optic disc by using optical coherence tomography and histological measurements
    Huang, Ju-Fang
    Yu, Hui-Min
    Shang, Lei
    Ma, Ruo-Fei
    Cynthia, Ngobe Akume
    Cao, Yan-Qun
    Luo, Jia
    Zeng, Le-Ping
    Chen, Dan
    Xiong, Kun
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2013, 6 (04) : 415 - 421
  • [4] Correlation Between Peripapillary Retinal Nerve Fiber Layer Thickness and Optic Nerve Head Parameters Using Spectral Domain Optical Coherence Tomography
    Mansoori, Tarannum
    Viswanath, Kalluri
    Balakrishna, Nagalla
    JOURNAL OF GLAUCOMA, 2010, 19 (09) : 604 - 608
  • [5] Correlation between optical coherence tomography and glaucomatous optic nerve head damage in children
    El-Dairi, M. A.
    Holgado, S.
    Asrani, S. G.
    Enyedi, L. B.
    Freedman, S. F.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (10) : 1325 - 1330
  • [6] Agreement in assessing cup-to-disc ratio measurement between stereoscopic optic nerve head photographs, Heidelberg Retinal Tomography, and optical coherence tomography
    Arthur, SN
    Aldridge, AJ
    DeLeon-Ortega, J
    McgWin, G
    Xie, A
    Girkin, CA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [7] Reproducibility of RTVue Retinal Nerve Fiber Layer Thickness and Optic Disc Measurements and Agreement with Stratus Optical Coherence Tomography Measurements
    Gonzalez-Garcia, Alberto O.
    Vizzeri, Gianmarco
    Bowd, Christopher
    Medeiros, Felipe A.
    Zangwill, Linda M.
    Weinreb, Robert N.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (06) : 1067 - 1074
  • [8] Retinal nerve fiber layer thickness evaluation using optical coherence tomography in eyes with optic disc hemorrhage
    Choi, Jin
    Park, Ki Ho
    Kim, Dong Myung
    Kim, Tae Woo
    OPHTHALMIC SURGERY LASERS & IMAGING, 2007, 38 (02) : 118 - 125
  • [9] Correlation between retinal nerve fibre layer thickness and optic nerve head size: an optical coherence tomography study
    Savini, G
    Zanini, M
    Carelli, V
    Sadun, AA
    Ross-Cisneros, FN
    Barboni, P
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (04) : 489 - 492
  • [10] Relationship Between Standard Automated Perimetry and Retinal Nerve Fiber Layer Parameters Obtained With Optical Coherence Tomography
    Lopez-Pena, Maria J.
    Ferreras, Antonio
    Larrosa, Jose M.
    Polo, Vicente
    Pablo, Luis E.
    JOURNAL OF GLAUCOMA, 2011, 20 (07) : 422 - 432