Reduced radiation dose and improved image quality at cardiovascular CT angiography by automated attenuation-based tube voltage selection: intra-individual comparison

被引:28
|
作者
Krazinski, Aleksander W. [1 ]
Meinel, Felix G. [1 ,2 ]
Schoepf, U. Joseph [1 ,3 ]
Silverman, Justin R. [1 ]
Canstein, Christian [4 ]
De Cecco, Carlo N. [1 ,5 ]
Geyer, Lucas L. [1 ,2 ]
机构
[1] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
[2] Ludwig Maximilians Univ Hosp, Inst Clin Radiol, Munich, Germany
[3] Med Univ S Carolina, Dept Med, Div Cardiol, Charleston, SC 29425 USA
[4] Siemens Healthcare, CT Div, Malvern, PA USA
[5] Univ Rome Sapienza Polo Pontino, Dept Radiol Sci Oncol & Pathol, Latina, Italy
关键词
CT angiography; Cardiac CT; Aorta; Radiation dose; Tube potential; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; DUAL-SOURCE CT; CORONARY-ANGIOGRAPHY; POTENTIAL SELECTION; CURRENT MODULATION; ABDOMINAL-AORTA; PEDIATRIC CT; CHEST CT; KILOVOLTAGE; REDUCTION;
D O I
10.1007/s00330-014-3312-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the effect of automated tube voltage selection on radiation dose and image quality at cardiovascular CT angiography (CTA). We retrospectively analysed paired studies in 72 patients (41 male, 60.5 +/- 16.5 years), who had undergone CTA acquisitions of the heart or aorta both before and after the implementation of an automated x-ray tube voltage selection algorithm (ATVS). All other parameters were kept identical between the two acquisitions. Subjective image quality (IQ) was rated and objective IQ was measured by image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and figure of merit (FOM). Image quality parameters and effective dose were compared between acquisitions. Overall subjective image quality improved with the percentage of cases scored as adequate or higher increasing from 79 % to 92 % after implementation of ATVS (P = 0.03). SNR (14.1 +/- 5.9, 15.7 +/- 6.1, P = 0.009), CNR (11.6 +/- 5.3, 13.2 +/- 5.6, P = 0.011), and FOM (19.9 +/- 23.3, 43.8 +/- 51.1, P < 0.001) were significantly higher after implementation of ATVS. Mean image noise (24.1 +/- 8.4 HU, 22.7 +/- 7.1 HU, P = 0.048) and mean effective dose (10.6 +/- 5.9 mSv, 8.8 +/- 5.0 mSv, P = 0.003) were significantly lower after implementation of ATVS. Automated tube voltage selection can operator-independently optimize cardiovascular CTA image acquisition parameters with improved image quality at reduced dose. aEuro cent Automatic tube voltage selection optimizes tube voltage for each individual patient. aEuro cent In this population, overall radiation dose decreased while image quality improved. aEuro cent This tool may become valuable for improving dose/quality ratio.
引用
收藏
页码:2677 / 2684
页数:8
相关论文
共 50 条
  • [41] Deep learning reconstruction versus iterative reconstruction for cardiac CT angiography in a stroke imaging protocol: reduced radiation dose and improved image quality
    Bernard, Angelique
    Comby, Pierre-Olivier
    Lemogne, Brivael
    Haioun, Karim
    Ricolfi, Frederic
    Chevallier, Olivier
    Loffroy, Romaric
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (01) : 392 - 401
  • [42] Prospective Coronary CT Angiography 128-MDCT Versus Retrospective 64-MDCT: Improved Image Quality and Reduced Radiation Dose
    Duarte, Ricardo
    Fernandez, Gabriel
    Castellon, Daniel
    Costa, Joao C.
    HEART LUNG AND CIRCULATION, 2011, 20 (02): : 119 - 125
  • [43] CT Angiography of the Head-and-Neck Vessels Acquired with Low Tube Voltage, Low Iodine, and Iterative Image Reconstruction: Clinical Evaluation of Radiation Dose and Image Quality
    Zhang, Wei-lan
    Li, Min
    Zhang, Bo
    Geng, Hai-yang
    Liang, Yin-qiang
    Xu, Ke
    Li, Song-bai
    PLOS ONE, 2013, 8 (12):
  • [44] Improved Image Quality and Decreased Radiation Dose of Lower Extremity Computed Tomography Angiography Using Low-Tube-Voltage and Adaptive Iterative Reconstruction
    Pan, Yu-Ning
    Li, Ai-Jing
    Chen, Zhao-Qian
    Ren, Da-Wei
    Zhang, Jie
    Jiang, Mao-Qing
    Huang, Qiu-Li
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (02) : 272 - 276
  • [45] Comparison of dose length product and image quality of a biphasic whole-body polytrauma CT protocol with and without the automatic tube voltage selection
    Girsa, David
    Kremenova, Karin
    Lukavsky, Jiri
    Sukupova, Lucie
    Malikova, Hana
    BIOMEDICAL PAPERS-OLOMOUC, 2024,
  • [46] Image quality of low-radiation dose left atrial CT using filtered back projection and an iterative reconstruction algorithm: intra-individual comparison in unselected patients undergoing pulmonary vein isolation
    Fahlenkamp, Ute Lina
    Ramirez, Ivan Diaz
    Wagner, Moritz
    Schwenke, Carsten
    Huppertz, Alexander
    Hamm, Bernd
    Lembcke, Alexander
    ACTA RADIOLOGICA, 2018, 59 (02) : 161 - 169
  • [47] Thoracic-abdominal imaging with a novel dual-layer spectral detector CT: intra-individual comparison of image quality and radiation dose with 128-row single-energy acquisition
    Haneder, Stefan
    Siedek, Florian
    Doerner, Jonas
    Pahn, Gregor
    Hokamp, Nils Grosse
    Maintz, David
    Wybranski, Christian
    ACTA RADIOLOGICA, 2018, 59 (12) : 1458 - 1465
  • [48] Reduced Radiation Exposure of the Female Breast During Low-Dose Chest CT Using Organ-Based Tube Current Modulation and a Bismuth Shield: Comparison of Image Quality and Radiation Dose
    Kim, Yoon Kyung
    Sung, Yon Mi
    Choi, Jin Ho
    Kim, Eun Young
    Kim, Hyung Sik
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (03) : 537 - 544
  • [49] Feasibility of coronary computed tomography angiography using automated attenuation-based selections of tube parameters in low radiation dose turbo flash mode in third generation 192-slice dual-source
    Speiser, U.
    Campan, M.
    Quick, S.
    Danowski, D.
    Platzek, I.
    Laniado, M.
    Strasser, R. H.
    EUROPEAN HEART JOURNAL, 2015, 36 : 769 - 769
  • [50] Improvement of Image Quality at Low-Radiation Dose and Low-Contrast Material Dose Abdominal CT in Patients With Cirrhosis: Intraindividual Comparison of Low Tube Voltage With Iterative Reconstruction Algorithm and Standard Tube Voltage
    Namimoto, Tomohiro
    Oda, Seitaro
    Utsunomiya, Daisuke
    Shimonobo, Toshiaki
    Morita, Sosuke
    Nakaura, Takeshi
    Yamashita, Yasuyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (04) : 495 - 501