Comparison of dose length product and image quality of a biphasic whole-body polytrauma CT protocol with and without the automatic tube voltage selection

被引:0
|
作者
Girsa, David [1 ,2 ,3 ]
Kremenova, Karin [1 ,2 ]
Lukavsky, Jiri [4 ,5 ]
Sukupova, Lucie [6 ]
Malikova, Hana [1 ,2 ,3 ]
机构
[1] Charles Univ Prague, Fac Med 3, Dept Radiol & Nucl Med, Prague, Czech Republic
[2] Fac Hosp Kralovske Vinohrady, Prague, Czech Republic
[3] Charles Univ Prague, Fac Med 2, Prague, Czech Republic
[4] Czech Acad Sci, Inst Psychol, Prague 11000, Czech Republic
[5] Charles Univ Prague, Fac Arts, Dept Psychol, Prague, Czech Republic
[6] Inst Clin & Expt Med, Directors Dept, Prague, Czech Republic
来源
关键词
whole body CT; polytrauma; automatic tube current modulation; automatic tube voltage selection; dose length product; CURRENT MODULATION; CANCER-RISKS; TRAUMA;
D O I
10.5507/bp.2024.004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background and Aims. A significant source of man-made radiation is now linked to medical devices especially X-ray imaging based ones like CT scans which expose the body to cumulative ionizing radiation and thus attendant cancer risks. The aim of this study was to determine whether using a combination of Automatic Tube Current Modulation (ATCM) and Automatic Tube Voltage Selection (ATVS) during two-phase whole-body CT (2PWBCT) examinations would reduce the radiation dose while preserving the image quality. Patients and Methods. This was a prospective, observational, single-centre study of 127 adult patients who had undergone the 2PWBCT polytraumatic protocol. All were examined on a Somatom Drive scanner (Siemens). The patients were divided into two groups: ATCM only (42 patients) and ATCM +ATVS (85 patients). Patients' arm positions during examination and the examination dose length product (DLP) values were recorded, as well the standard deviations (SD) of the density in reference areas on CT scans for the image quality assessment. The DLP values and image quality in the groups were compared using ANOVA. Results. Mean Total DLP (in mGy*cm): ATCM only: 3337 +/-797, ATCM+ATVS: 3402 +/-830; P=0.674. No effect of arm position (P=0.586). Mean density SD values in reference areas (in HU) in ATCM only: 49 +/-45, 15 +/-6, 9 +/-2, 12 +/-4, 10 +/-3, in ATCM+ATVS: 48 +/-45, 17 +/-6, 11 +/-3, 15 +/-6, 12 +/-4. SD values was higher in ATCM+ATVS group (P<0.001). Conclusion. Combination of ATVS and ATCM in polytraumatic 2PWBCT leads to no significant radiation load reduction compared with ATCM only but does lead to a slight degradation of image quality. The radiation load is significantly reduced if the patient has their arms behind the head when scanning, regardless of the activation of ATVS.
引用
收藏
页数:7
相关论文
共 49 条
  • [1] Automatic tube current modulation for whole-body polytrauma CT with immobilization devices: is there an increase in radiation dose and degradation of image quality?
    Euler A.
    Stieltjes B.
    Schindera S.T.
    Emergency Radiology, 2017, 24 (1) : 31 - 37
  • [2] Conversion from dose length product to effective dose for the CT component of whole-body PET/CT
    Inoue, Yusuke
    Ohkubo, Yu
    Nagahara, Kazunori
    Uehara, Ayuka
    Takano, Makoto
    ANNALS OF NUCLEAR MEDICINE, 2022, 36 (04) : 411 - 419
  • [3] Conversion from dose length product to effective dose for the CT component of whole-body PET/CT
    Yusuke Inoue
    Yu Ohkubo
    Kazunori Nagahara
    Ayuka Uehara
    Makoto Takano
    Annals of Nuclear Medicine, 2022, 36 : 411 - 419
  • [4] Whole-body CT in polytrauma patients: Effect of arm positioning on thoracic and abdominal image quality
    Karlo C.
    Gnannt R.
    Frauenfelder T.
    Leschka S.
    Brüesch M.
    Wanner G.A.
    Alkadhi H.
    Emergency Radiology, 2011, 18 (4) : 285 - 293
  • [5] Effects of tube voltage and iodine contrast medium on radiation dose of whole-body CT
    Yoshida, Morikatsu
    Nakaura, Takeshi
    Oda, Seitaro
    Kidoh, Masafumi
    Nagayama, Yasunori
    Uetani, Hiroyuki
    Azuma, M.
    Sakabe, Daisuke
    Hirai, Toshinori
    Funama, Yoshinori
    ACTA RADIOLOGICA, 2022, 63 (04) : 458 - 466
  • [6] Effect of automatic tube voltage selection on image quality and radiation dose in abdominal CT angiography of various body sizes: A phantom study
    Schindera, S. T.
    Winklehner, A.
    Alkadhi, H.
    Goetti, R.
    Fischer, M.
    Gnannt, R.
    Szucs-Farkas, Z.
    CLINICAL RADIOLOGY, 2013, 68 (02) : E79 - E86
  • [7] Automatic Tube Potential Selection with Tube Current Modulation (APSCM) in coronary CT angiography: Comparison of image quality and radiation dose with conventional body mass index-based protocol
    Park, Young Jean
    Kim, Young Jin
    Lee, Ji Won
    Kim, Hee Yeong
    Hong, Yoo Jin
    Lee, Hye-Jeong
    Hur, Jin
    Nam, Ji Eun
    Choi, Byoung Wook
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (03) : 184 - 190
  • [8] Impact of Radiation Dose Reduction of CT component in Whole-Body PET/CT Protocols on CT Image quality
    Ali, I.
    Mohamed, Y.
    Naser, I.
    Amin, M. I.
    Gawad, H. Abdel
    Hamdy, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S781 - S782
  • [9] Whole-body CT in polytrauma patients: The effect of arm position on abdominal image quality when using a human phantom
    Pil-Hyun Jeon
    Hee-Joung Kim
    Chang-Lae Lee
    Dae-Hong Kim
    Won-Hyung Lee
    Sung-Su Jeon
    Journal of the Korean Physical Society, 2012, 60 : 1967 - 1972
  • [10] Whole-body CT in polytrauma patients: The effect of arm position on abdominal image quality when using a human phantom
    Jeon, Pil-Hyun
    Kim, Hee-Joung
    Lee, Chang-Lae
    Kim, Dae-Hong
    Lee, Won-Hyung
    Jeon, Sung-Su
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (11) : 1967 - 1972