Reduced radiation dose and improved image quality at cardiovascular CT angiography by automated attenuation-based tube voltage selection: intra-individual comparison

被引:28
|
作者
Krazinski, Aleksander W. [1 ]
Meinel, Felix G. [1 ,2 ]
Schoepf, U. Joseph [1 ,3 ]
Silverman, Justin R. [1 ]
Canstein, Christian [4 ]
De Cecco, Carlo N. [1 ,5 ]
Geyer, Lucas L. [1 ,2 ]
机构
[1] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
[2] Ludwig Maximilians Univ Hosp, Inst Clin Radiol, Munich, Germany
[3] Med Univ S Carolina, Dept Med, Div Cardiol, Charleston, SC 29425 USA
[4] Siemens Healthcare, CT Div, Malvern, PA USA
[5] Univ Rome Sapienza Polo Pontino, Dept Radiol Sci Oncol & Pathol, Latina, Italy
关键词
CT angiography; Cardiac CT; Aorta; Radiation dose; Tube potential; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; DUAL-SOURCE CT; CORONARY-ANGIOGRAPHY; POTENTIAL SELECTION; CURRENT MODULATION; ABDOMINAL-AORTA; PEDIATRIC CT; CHEST CT; KILOVOLTAGE; REDUCTION;
D O I
10.1007/s00330-014-3312-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the effect of automated tube voltage selection on radiation dose and image quality at cardiovascular CT angiography (CTA). We retrospectively analysed paired studies in 72 patients (41 male, 60.5 +/- 16.5 years), who had undergone CTA acquisitions of the heart or aorta both before and after the implementation of an automated x-ray tube voltage selection algorithm (ATVS). All other parameters were kept identical between the two acquisitions. Subjective image quality (IQ) was rated and objective IQ was measured by image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and figure of merit (FOM). Image quality parameters and effective dose were compared between acquisitions. Overall subjective image quality improved with the percentage of cases scored as adequate or higher increasing from 79 % to 92 % after implementation of ATVS (P = 0.03). SNR (14.1 +/- 5.9, 15.7 +/- 6.1, P = 0.009), CNR (11.6 +/- 5.3, 13.2 +/- 5.6, P = 0.011), and FOM (19.9 +/- 23.3, 43.8 +/- 51.1, P < 0.001) were significantly higher after implementation of ATVS. Mean image noise (24.1 +/- 8.4 HU, 22.7 +/- 7.1 HU, P = 0.048) and mean effective dose (10.6 +/- 5.9 mSv, 8.8 +/- 5.0 mSv, P = 0.003) were significantly lower after implementation of ATVS. Automated tube voltage selection can operator-independently optimize cardiovascular CTA image acquisition parameters with improved image quality at reduced dose. aEuro cent Automatic tube voltage selection optimizes tube voltage for each individual patient. aEuro cent In this population, overall radiation dose decreased while image quality improved. aEuro cent This tool may become valuable for improving dose/quality ratio.
引用
收藏
页码:2677 / 2684
页数:8
相关论文
共 50 条
  • [31] Image quality and radiation dose of low-tube-voltage CT with reduced contrast media for right adrenal vein imaging
    Takahashi, Yuki
    Ota, Hideki
    Omura, Kensuke
    Dendo, Yutaka
    Otani, Katharina
    Matsuura, Tomonori
    Kitami, Masahiro
    Seiji, Kazumasa
    Tezuka, Yuta
    Nezu, Masahiro
    Ono, Yoshikiyo
    Morimoto, Ryo
    Satoh, Fumitoshi
    Takase, Kei
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 98 : 150 - 157
  • [32] Deep Learning Versus Iterative Reconstruction for CT Pulmonary Angiography in the Emergency Setting: Improved Image Quality and Reduced Radiation Dose
    Lenfant, Marc
    Chevallier, Olivier
    Comby, Pierre-Olivier
    Secco, Gregory
    Haioun, Karim
    Ricolfi, Frederic
    Lemogne, Brivael
    Loffroy, Romaric
    DIAGNOSTICS, 2020, 10 (08)
  • [33] Assessment of CT Radiation Dose and Image Quality for An Automated Tube Potential Selection Algorithm Using Adult Anthropomorphic and ACR Phantoms
    Mahmood, U.
    Erdi, Y.
    Wang, W.
    MEDICAL PHYSICS, 2014, 41 (06) : 149 - 149
  • [34] Standard chest CT using combined automated tube potential selection and iterative reconstruction: image quality and radiation dose reduction
    Chae, In Hye
    Kim, Yookyung
    Lee, So Won
    Park, Ji Eun
    Shim, Sung Shine
    Lee, Jin Hwa
    CLINICAL IMAGING, 2014, 38 (05) : 641 - 647
  • [35] Scout View X-Ray Attenuation Versus Weight-Based Selection of Reduced Peak Tube Voltage in Cardiac CT Angiography
    Ghafourian, Kambiz
    Younes, Desiree
    Simprini, Lauren A.
    Weigold, Wm Guy
    Weissman, Gaby
    Taylor, Allen J.
    JACC-CARDIOVASCULAR IMAGING, 2012, 5 (06) : 589 - 595
  • [36] Automated tube voltage selection for radiation dose and contrast medium reduction at coronary CT angiography using 3rd generation dual-source CT
    Mangold, Stefanie
    Wichmann, Julian L.
    Schoepf, U. Joseph
    Poole, Zachary B.
    Canstein, Christian
    Varga-Szemes, Akos
    Caruso, Damiano
    Bamberg, Fabian
    Nikolaou, Konstantin
    De Cecco, Carlo N.
    EUROPEAN RADIOLOGY, 2016, 26 (10) : 3608 - 3616
  • [37] Automated tube voltage selection for radiation dose and contrast medium reduction at coronary CT angiography using 3rd generation dual-source CT
    Stefanie Mangold
    Julian L. Wichmann
    U. Joseph Schoepf
    Zachary B. Poole
    Christian Canstein
    Akos Varga-Szemes
    Damiano Caruso
    Fabian Bamberg
    Konstantin Nikolaou
    Carlo N. De Cecco
    European Radiology, 2016, 26 : 3608 - 3616
  • [38] Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose
    Earls, James P.
    Berman, Elise L.
    Urban, Bruce A.
    Curry, Charlene A.
    Lane, Judith L.
    Jennings, Robert S.
    McCulloch, Colin C.
    Hsieh, Jiang
    Londt, John H.
    RADIOLOGY, 2008, 246 (03) : 742 - 753
  • [39] Attenuation-Based Automatic Kilovoltage Selection and Sinogram-Affirmed Iterative Reconstruction: Effects on Radiation Exposure and Image Quality of Portal-Phase Liver CT
    Song, Ji Soo
    Choi, Eun Jung
    Kim, Eun Young
    Kwak, Hyo Sung
    Han, Young Min
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (01) : 69 - 79
  • [40] Comparison of image quality and radiation dose in computed tomography angiography of the peripheral arteries using tube voltage of 80 kV versus 100 kV
    Pernas, R. Oca
    Delgado Sanchez-Gracian, C.
    Tardaguila de la Fuente, G.
    Fernandez del Valle, A.
    Silva Priegue, N.
    Gonzalez Vazquez, M.
    Trinidad Lopez, C.
    RADIOLOGIA, 2014, 56 (06): : 541 - 547